99 research outputs found

    Optical Modeling of Microcrystalline Silicon Deposited by Plasma-Enhanced Chemical Vapor Deposition on Low-Cost Iron-Nickel Substrates for Photovoltaic Applications

    Get PDF
    AbstractThis paper deals with the optical modeling of thin hydrogenated microcrystalline silicon films grown on flexible low-cost iron-nickel alloy substrates by low-temperature (175°C) plasma-enhanced chemical vapor deposition. This material serves as the absorber in solar cells and hence it has direct impact on the resulting solar cell performance. Since the crystallinity and the material quality of hydrogenated microcrystalline silicon films evolve during the growth, the deposited film is inhomogeneous, with a rather complex structure. Real-time spectroscopic ellipsometry has been used to trace the changing composition of the films. In-situ ellipsometric data taken for photon energies from 2.8 to 4.5eV every 50seconds enabled us to study the evolution of the monocrystalline silicon fraction of the hydrogenated microcrystalline silicon films

    Surface integrity of Mg-based nanocomposite produced by Abrasive Water Jet Machining (AWJM)

    Get PDF
    This paper investigates the influence of jet traverse speed on the surface integrity of 0.66 wt% Al2O3 nanoparticle reinforced metal matrix composite (MMC) generated by Abrasive Water Jet Machining (AWJM). Surface morphology, surface topography, and surface roughness (SR) of the AWJ surface were analyzed. The machined surfaces of the nanocomposites were examined by laser confocal microscope and field emission scanning electron microscope (FESEM). Microhardness and elasticity modulus measurement by nanoindentation testing were also performed across thickness of the samples to see depth of the zone, affected by AWJ cutting. The result reveals that extent of grooving by abrasive particle and irregularity in AWJ machined surface increases as the traverse speed increased. Similarly, the rise in value of surface roughness parameters with traverse speed was also seen. In addition, nanoindentation testing represents the lower hardness and elastic modulus due to softening occurs in AWJ surface

    Rising utilization of coronary CT angiography across Europe over the last decade: insights from a large prospective European registry

    Get PDF
    Abstract Background/Introduction The recently updated 2019 ESC guidelines for the diagnosis and management of chronic coronary syndromes endorse the use of coronary computed tomography angiography (CCTA) for exclusion of obstructive coronary artery disease in patients with a low clinical likelihood (Class I, LOE B). Higher demand for CCTA requires broad availability, inevitably involving smaller healthcare providers, such as non-academic hospitals and private practices. Nevertheless, most published data on CCTA image quality and safety rely on exams performed in high-volume academic centers, and little is known about CCTA in non-academic settings. Purpose To investigate the utilization of CCTA across Europe over the last decade, focusing on differences between academic and non-academic centers. Methods We included patients with stable chest pain and suspected coronary artery disease (CAD) who received CCTA and were included in the European Society of Cardiovascular Radiology MR/CT registry 01/2010–01/2020. We compared CT equipment, image quality, radiation dose, the incidence of periprocedural adverse events, patient characteristics, and CCTA findings between academic (high volume university hospitals) and non-academic centers (non-academic hospitals and private practices). Results Overall, 64,317 patients (41.2% women; age 60±13 years) from 212 sites across 19 European countries were included. Academic centers submitted most cases in 2010—2014 (51.6%), whereas non-academic centers accounted for 71.3% of records in 2015–2020. While non-academic centers used less advanced technology, radiation dose remained low (4.54 [interquartile range (IQR) 2.28–6.76] mSv) with a 30% decline of high-dose scans (>7 mSv) over time. Diagnostic image quality was reported in 97.7% of cases, and the rate of acute scan-related events was low (0.4%) (Figure 1). From 2010–2014 to 2015–2020, CCTA nearly doubled in patients with low to intermediate pretest-probability, women >50, and 40–60 years old men (Figure 2). CAD presence and extent decreased slightly over time (prevalence: 2010–2014: 41.5% vs. 2015–2020: 40.6%), (multi-vessel disease in those with CAD: 2010–2014: 61.9% vs. 2015–2020: 55.9%; all p<0.01). Conclusion CCTA expands rapidly to non-academic centers across Europe, increasing availability while maintaining relatively low radiation dose, high diagnostic image quality, and safety. Broad availability of high-quality CCTA is essential for a successfully implementation of the recently updated guidelines for the diagnosis and management of chronic coronary syndromes. Funding Acknowledgement Type of funding sources: None. Changes in CCTA utilizationChanges in patient characteristic

    Small whole heart volume predicts cardiovascular events in patients with stable chest pain: insights from the PROMISE trial

    Get PDF
    Objectives The size of the heart may predict major cardiovascular events (MACE) in patients with stable chest pain. We aimed to evaluate the prognostic value of 3D whole heart volume (WHV) derived from non-contrast cardiac computed tomography (CT). Methods Among participants randomized to the CT arm of the Prospective Multicenter Imaging Study for Evaluation of Chest Pain (PROMISE), we used deep learning to extract WHV, defined as the volume of the pericardial sac. We compared the WHV across categories of cardiovascular risk factors and coronary artery disease (CAD) characteristics and determined the association of WHV with MACE (all-cause death, myocardial infarction, unstable angina; median follow-up: 26 months). Results In the 3798 included patients (60.5 +/- 8.2 years; 51.5% women), the WHV was 351.9 +/- 57.6 cm(3)/m(2). We found smaller WHV in no- or non-obstructive CAD, women, people with diabetes, sedentary lifestyle, and metabolic syndrome. Larger WHV was found in obstructive CAD, men, and increased atherosclerosis cardiovascular disease (ASCVD) risk score (p < 0.05). In a time-to-event analysis, small WHV was associated with over 4.4-fold risk of MACE (HR (per one standard deviation) = 0.221; 95% CI: 0.068-0.721; p = 0.012) independent of ASCVD risk score and CT-derived CAD characteristics. In patients with non-obstructive CAD, but not in those with no- or obstructive CAD, WHV increased the discriminatory capacity of ASCVD and CT-derived CAD characteristics significantly. Conclusions Small WHV may represent a novel imaging marker of MACE in stable chest pain. In particular, WHV may improve risk stratification in patients with non-obstructive CAD, a cohort with an unmet need for better risk stratification

    Flexible Photodiodes Based on Nitride Core/Shell p-n Junction Nanowires

    Get PDF
    International audienceA flexible nitride p-n photodiode is demonstrated. The device consists of a composite nanowire/polymer membrane trans- ferred onto a flexible substrate. The active element for light sensing is a vertical array of core/shell p−n junction nanowires containing InGaN/ GaN quantum wells grown by MOVPE. Electron/hole generation and transport in core/shell nanowires are modeled within nonequilibrium Green function formalism showing a good agreement with experimental results. Fully flexible transparent contacts based on a silver nanowire network are used for device fabrication, which allows bending the detector to a few millimeter curvature radius without damage. The detector shows a photoresponse at wavelengths shorter than 430 nm with a peak responsivity of 0.096 A/W at 370 nm under zero bias. The operation speed for a 0.3 × 0.3 cm2 detector patch was tested between 4 Hz and 2 kHz. The −3 dB cutoff was found to be ∼35 Hz, which is faster than the operation speed for typical photoconductive detectors and which is compatible with UV monitoring applications

    Spectroscopic ellipsometry and polarimetry for materials and systems analysis at the nanometer scale: state-of-the-art, potential, and perspectives

    Get PDF
    This paper discusses the fundamentals, applications, potential, limitations, and future perspectives of polarized light reflection techniques for the characterization of materials and related systems and devices at the nanoscale. These techniques include spectroscopic ellipsometry, polarimetry, and reflectance anisotropy. We give an overview of the various ellipsometry strategies for the measurement and analysis of nanometric films, metal nanoparticles and nanowires, semiconductor nanocrystals, and submicron periodic structures. We show that ellipsometry is capable of more than the determination of thickness and optical properties, and it can be exploited to gain information about process control, geometry factors, anisotropy, defects, and quantum confinement effects of nanostructures
    corecore