    Heparin stability in parenteral nutrition bags prepared in a neonatal ICU

    Full text link

    Prevention of adverse drug effects associated with intravenous infusion in anesthesia and intensive care : assessment of the impact of innovative infusion devices

    No full text
    La perfusion intraveineuse (IV) est un acte de soins courant dans les services cliniques mais non dépourvu de risque. De nombreux paramètres influencent la vitesse d’administration (ou débit massique) des médicaments perfusés, en particulier les dispositifs médicaux employés pour l'administration d'un ou plusieurs produits. De part leurs caractéristiques, ces dispositifs peuvent générer des fluctuations plus ou moins importantes du débit massique du produit au cours de sa perfusion.La première partie de ce travail est une analyse de la littérature concernant l'impact des dispositifs médicaux sur le débit massique des médicaments délivrés par voie IV. Une revue systématique de la littérature sur cette thématique a retrouvé des études essentiellement in vitro portant sur tout facteur susceptible de modifier le débit ou la concentration du médicament administré.La première partie de nos travaux expérimentaux est consacrée à la prévention des variations intempestives du débit massique de la solution médicamenteuse perfusée au patient par voie IV. Le premier travail a montré in vitro la capacité d'un nouveau dispositif de perfusion multilumière à très faible volume interne (Multiline-8, Doran International, France) à prévenir les variations intempestives de débit massique dans un contexte de multiperfusion et lors d'un arrêt/reprise de l'hydratation. Le second travail a démontré in vitro l'impact de la conception du montage de perfusion sur la précision des doses de morphine administrées en analgésie contrôlée par le patient. L'utilisation d'un montage en Y à faible volume interne améliore significativement la précision de la dose de morphine délivrée lors des bolus et réduit la délivrance de morphine lors des périodes réfractaires. Ainsi, l'utilisation de dispositifs médicaux de perfusion à faible volume interne limite les variations de débit massique et par conséquent, leur impact clinique.La seconde partie de nos travaux est axée sur la prévention des incompatibilités médicamenteuses lorsque plusieurs traitements sont administrés simultanément. Le premier travail mené dans cette thématique a montré in vitro la capacité de dispositifs de perfusion multilumières à prévenir la survenue d'une incompatibilité physico-chimique entre deux médicaments réputés incompatibles (furosémide/midazolam). Nos résultats indiquent que trois facteurs ont un impact sur la compatibilité physique entre les produits : la concentration du médicament, le débit d'hydratation et la conception du dispositif de perfusion. Notre principale hypothèse est que les conditions de mélange des fluides diffèrent selon le dispositif de perfusion, modifiant le temps de contact entre les deux médicaments et la solution saline. Le second travail consiste en une quantification in vitro de la perte de médicament lors d'une incompatibilité médicamenteuse avec l'exemple de l'incompatibilité physique entre le furosémide et le midazolam. Notre étude a révélé que l'incompatibilité physique entre deux médicaments peut conduire à une réduction significative des quantités de produit délivrées au patient, même en l'absence de particules visibles. En effet, la précipitation du furosémide responsable de la formation de particules visibles et/ou non visibles a entraîné une perte du médicament estimée entre 10 et 15 %, en présence de midazolam. La prévention des incompatibilités constitue un enjeu majeur pour garantir la sécurité et l'efficacité des produits injectés.Les résultats de l'ensemble de nos études menées in vitro doivent être validés dans un contexte clinique afin de déterminer les conséquences du choix du dispositif sur l'efficacité et la sécurité des thérapeutiques IV administrées au patient.Intravenous (IV) infusion is a common medical act in clinical wards, although not without risk. Many factors affect drug delivery rate (or drug mass flow rate), especially medical devices used to administer one or more drugs. By their very features, these devices may generate more or less significant variations in drug mass flow rate during infusion.The first part of this work consisted in analysing published literature dealing with the impact of medical devices on drug mass flow rate when delivered intravenously. This systematic review revealed mainly in vitro studies on all factors likely to alter the flow rate or concentration of the drug infused.The first stage of our experimental work is dedicated to preventing hazardous disturbances in the mass flow rate of the drug solution infused intravenously to the patient. It showed in vitro the ability of a new multi-lumen infusion access device with a very low internal volume (Multiline-8, Doran International, France) to prevent such disturbances in drug delivery in the context of multi-infusion therapy and when interrupting and resuming carrier fluid flow. The second stage demonstrated in vitro the impact of infusion set characteristics on the accuracy of morphine doses in patient-controlled analgesia. The use of a low dead space volume Y-set significantly improved the accuracy of the morphine dose delivered during bolus and reduced morphine infusion during lockout intervals. Thus, the use of infusion devices with a very low internal volume minimises variations in drug mass flow rate and consequently, clinical impact.The second part of our work focused on the prevention of drug incompatibilities when several treatments are administered simultaneously. The first task accomplished on this topic showed in vitro the ability of multi-lumen infusion access devices to prevent the occurrence of physicochemical incompatibility between two drugs known to be incompatible (furosemide/midazolam). Our results indicate that three factors impact on physical compatibility between drugs: drug concentration, carrier flow rate and the design of the infusion device. Our main hypothesis is that fluid dynamics differ according to infusion devices which modify contact time between the two drugs and saline. The second task was an in vitro quantification of drug loss in the case of drug incompatibility using the example of furosemide and midazolam. Our study revealed that physical incompatibility between two drugs can lead to a significant reduction in drug delivery to the patient, even in the absence of visible particles. Indeed, furosemide precipitation resulting in the formation of visible and/or sub-visible particles led to a drug loss to the patient estimated at between 10% and 15% when midazolam was present. Preventing incompatibilities is a major challenge to ensure the safety and effectiveness of injectable drugs.The results of the whole of our in vitro studies must be validated in a clinical setting to determine the extent to which the choice of device affects the efficiency and safety of IV therapeutics administered to the patient

    Prévention des événements indésirables médicamenteux associés à la perfusion en anesthésie-réanimation : évaluation de l'impact de dispositifs médicaux de perfusion innovants

    No full text
    Intravenous (IV) infusion is a common medical act in clinical wards, although not without risk. Many factors affect drug delivery rate (or drug mass flow rate), especially medical devices used to administer one or more drugs. By their very features, these devices may generate more or less significant variations in drug mass flow rate during infusion.The first part of this work consisted in analysing published literature dealing with the impact of medical devices on drug mass flow rate when delivered intravenously. This systematic review revealed mainly in vitro studies on all factors likely to alter the flow rate or concentration of the drug infused.The first stage of our experimental work is dedicated to preventing hazardous disturbances in the mass flow rate of the drug solution infused intravenously to the patient. It showed in vitro the ability of a new multi-lumen infusion access device with a very low internal volume (Multiline-8, Doran International, France) to prevent such disturbances in drug delivery in the context of multi-infusion therapy and when interrupting and resuming carrier fluid flow. The second stage demonstrated in vitro the impact of infusion set characteristics on the accuracy of morphine doses in patient-controlled analgesia. The use of a low dead space volume Y-set significantly improved the accuracy of the morphine dose delivered during bolus and reduced morphine infusion during lockout intervals. Thus, the use of infusion devices with a very low internal volume minimises variations in drug mass flow rate and consequently, clinical impact.The second part of our work focused on the prevention of drug incompatibilities when several treatments are administered simultaneously. The first task accomplished on this topic showed in vitro the ability of multi-lumen infusion access devices to prevent the occurrence of physicochemical incompatibility between two drugs known to be incompatible (furosemide/midazolam). Our results indicate that three factors impact on physical compatibility between drugs: drug concentration, carrier flow rate and the design of the infusion device. Our main hypothesis is that fluid dynamics differ according to infusion devices which modify contact time between the two drugs and saline. The second task was an in vitro quantification of drug loss in the case of drug incompatibility using the example of furosemide and midazolam. Our study revealed that physical incompatibility between two drugs can lead to a significant reduction in drug delivery to the patient, even in the absence of visible particles. Indeed, furosemide precipitation resulting in the formation of visible and/or sub-visible particles led to a drug loss to the patient estimated at between 10% and 15% when midazolam was present. Preventing incompatibilities is a major challenge to ensure the safety and effectiveness of injectable drugs.The results of the whole of our in vitro studies must be validated in a clinical setting to determine the extent to which the choice of device affects the efficiency and safety of IV therapeutics administered to the patient.La perfusion intraveineuse (IV) est un acte de soins courant dans les services cliniques mais non dépourvu de risque. De nombreux paramètres influencent la vitesse d’administration (ou débit massique) des médicaments perfusés, en particulier les dispositifs médicaux employés pour l'administration d'un ou plusieurs produits. De part leurs caractéristiques, ces dispositifs peuvent générer des fluctuations plus ou moins importantes du débit massique du produit au cours de sa perfusion.La première partie de ce travail est une analyse de la littérature concernant l'impact des dispositifs médicaux sur le débit massique des médicaments délivrés par voie IV. Une revue systématique de la littérature sur cette thématique a retrouvé des études essentiellement in vitro portant sur tout facteur susceptible de modifier le débit ou la concentration du médicament administré.La première partie de nos travaux expérimentaux est consacrée à la prévention des variations intempestives du débit massique de la solution médicamenteuse perfusée au patient par voie IV. Le premier travail a montré in vitro la capacité d'un nouveau dispositif de perfusion multilumière à très faible volume interne (Multiline-8, Doran International, France) à prévenir les variations intempestives de débit massique dans un contexte de multiperfusion et lors d'un arrêt/reprise de l'hydratation. Le second travail a démontré in vitro l'impact de la conception du montage de perfusion sur la précision des doses de morphine administrées en analgésie contrôlée par le patient. L'utilisation d'un montage en Y à faible volume interne améliore significativement la précision de la dose de morphine délivrée lors des bolus et réduit la délivrance de morphine lors des périodes réfractaires. Ainsi, l'utilisation de dispositifs médicaux de perfusion à faible volume interne limite les variations de débit massique et par conséquent, leur impact clinique.La seconde partie de nos travaux est axée sur la prévention des incompatibilités médicamenteuses lorsque plusieurs traitements sont administrés simultanément. Le premier travail mené dans cette thématique a montré in vitro la capacité de dispositifs de perfusion multilumières à prévenir la survenue d'une incompatibilité physico-chimique entre deux médicaments réputés incompatibles (furosémide/midazolam). Nos résultats indiquent que trois facteurs ont un impact sur la compatibilité physique entre les produits : la concentration du médicament, le débit d'hydratation et la conception du dispositif de perfusion. Notre principale hypothèse est que les conditions de mélange des fluides diffèrent selon le dispositif de perfusion, modifiant le temps de contact entre les deux médicaments et la solution saline. Le second travail consiste en une quantification in vitro de la perte de médicament lors d'une incompatibilité médicamenteuse avec l'exemple de l'incompatibilité physique entre le furosémide et le midazolam. Notre étude a révélé que l'incompatibilité physique entre deux médicaments peut conduire à une réduction significative des quantités de produit délivrées au patient, même en l'absence de particules visibles. En effet, la précipitation du furosémide responsable de la formation de particules visibles et/ou non visibles a entraîné une perte du médicament estimée entre 10 et 15 %, en présence de midazolam. La prévention des incompatibilités constitue un enjeu majeur pour garantir la sécurité et l'efficacité des produits injectés.Les résultats de l'ensemble de nos études menées in vitro doivent être validés dans un contexte clinique afin de déterminer les conséquences du choix du dispositif sur l'efficacité et la sécurité des thérapeutiques IV administrées au patient

    Impact of physical incompatibility on drug mass flow rates: example of furosemide-midazolam incompatibility.

    Get PDF
    International audienceABSTRACT: BACKGROUND: Patients in intensive care units receive many drugs simultaneously but through limited venous accesses. Several intravenous therapies have to be administered through the same catheter, thus increasing the risk of physicochemical incompatibility. The purpose of this work was to assess and to quantify the impact of physical incompatibility on the mass flow rates of drugs infused simultaneously to the patient, through an in vitro study. METHODS: Furosemide-midazolam incompatibility was used to assess the impact of physical incompatibility on drug mass flow rates. Furosemide, midazolam, and saline were simultaneously infused. A filter was added at the end of the infusion line to retain visible particles. Two infusion conditions were tested with and without visible particles. A partial least square method on UV spectra was used to determine simultaneously the concentrations of the two drugs at the egress of the terminal extension line. The drug mass flow rate (expressed as mg/h) was calculated as the product of drug concentration versus total flow rate. Observed/theoretical mass flow rate ratios for each drug (%) were determined per infusion condition. RESULTS: Even in the absence of visible particles, precipitation of furosemide led to a drug loss estimated at between 10 % and 15 %. Furosemide is more impacted by interaction because the pH of the mixture is acid and this form is poorly soluble in an aqueous solution. CONCLUSIONS: Physical incompatibility between furosemide and midazolam leads to a significant reduction in drug delivered to the patient and may result in treatment failure

    Influence of a Double-Lumen Extension Tube on Drug Delivery: Examples of Isosorbide Dinitrate and Diazepam

    No full text
    International audiencePURPOSE: Plastic materials such as polyurethane (PUR), polyethylene (PE), polypropylene (PP) and polyvinyl chloride (PVC) are widely used in double-lumen extension tubing. The purposes of our study were to 1) compare in vitro drug delivery through the double extension tubes available on the market 2) assess the plastic properties of PUR in infusion devices and their impact on drug delivery.METHODS: The study compared eight double-lumen extension tubes in PUR, co-extruded (PE/PVC) plastic and plasticised PVC from different manufacturers. Isosorbide dinitrate and diazepam were used as model compounds to evaluate their sorption on the internal surface of the infusion device. Control experiments were performed using norepinephrine known not to absorb to plastics. Drug concentrations delivered at the egress of extension tubes were determined over time by an analytical spectrophotometric UV-Vis method. The main characteristics of plastics were also determined.RESULTS: Significant differences in the sorption phenomenon were observed among the eight double-lumen extension tubes and between pairs of extension tubes. Mean concentrations of isosorbide dinitrate delivered at the egress of double-lumen extension tubes after a 150-minute infusion (mean values ± standard deviation in percentage of the initial concentrations in the prepared syringes) ranged between 80.53 ± 1.66 (one of the PUR tubes) and 92.84 ± 2.73 (PE/PVC tube). The same parameters measured during diazepam infusion ranged between 48.58 ± 2.88 (one of the PUR tubes) and 85.06 ± 3.94 (PE/PVC tube). The double-lumen extension tubes in PUR were either thermosetting (resin) or thermoplastic according to reference.CONCLUSIONS: Clinicians must be aware of potential drug interactions with extension tube materials and so must consider their nature as well as the sterilisation method used before selecting an infusion device