16 research outputs found
Commissioning of the vacuum system of the KATRIN Main Spectrometer
The KATRIN experiment will probe the neutrino mass by measuring the
beta-electron energy spectrum near the endpoint of tritium beta-decay. An
integral energy analysis will be performed by an electro-static spectrometer
(Main Spectrometer), an ultra-high vacuum vessel with a length of 23.2 m, a
volume of 1240 m^3, and a complex inner electrode system with about 120000
individual parts. The strong magnetic field that guides the beta-electrons is
provided by super-conducting solenoids at both ends of the spectrometer. Its
influence on turbo-molecular pumps and vacuum gauges had to be considered. A
system consisting of 6 turbo-molecular pumps and 3 km of non-evaporable getter
strips has been deployed and was tested during the commissioning of the
spectrometer. In this paper the configuration, the commissioning with bake-out
at 300{\deg}C, and the performance of this system are presented in detail. The
vacuum system has to maintain a pressure in the 10^{-11} mbar range. It is
demonstrated that the performance of the system is already close to these
stringent functional requirements for the KATRIN experiment, which will start
at the end of 2016.Comment: submitted for publication in JINST, 39 pages, 15 figure
Age-associated B cells predict impaired humoral immunity after COVID-19 vaccination in patients receiving immune checkpoint blockade
Age-associated B cells (ABC) accumulate with age and in individuals with different immunological disorders, including cancer patients treated with immune checkpoint blockade and those with inborn errors of immunity. Here, we investigate whether ABCs from different conditions are similar and how they impact the longitudinal level of the COVID-19 vaccine response. Single-cell RNA sequencing indicates that ABCs with distinct aetiologies have common transcriptional profiles and can be categorised according to their expression of immune genes, such as the autoimmune regulator (AIRE). Furthermore, higher baseline ABC frequency correlates with decreased levels of antigen-specific memory B cells and reduced neutralising capacity against SARS-CoV-2. ABCs express high levels of the inhibitory FcÎłRIIB receptor and are distinctive in their ability to bind immune complexes, which could contribute to diminish vaccine responses either directly, or indirectly via enhanced clearance of immune complexed-antigen. Expansion of ABCs may, therefore, serve as a biomarker identifying individuals at risk of suboptimal responses to vaccination
Monitoring of the operating parameters of the KATRIN Windowless Gaseous Tritium Source
The KArlsruhe TRItium Neutrino (KATRIN) experiment will measure the absolute mass scale of neutrinos with a sensitivity of mnu = 200 meV/c2 by high-precision spectroscopy close to the tritium beta-decay endpoint at 18.6 keV. Its Windowless Gaseous Tritium Source (WGTS) is a beta-decay source of high intensity (1011 sâ1) and stability, where high-purity molecular tritium at 30 K is circulated in a closed loop with a yearly throughput of 10 kg. To limit systematic effects the column density of the source has to be stabilized at the 10â3 level. This requires extensive sensor instrumentation and dedicated control and monitoring systems for parameters such as the beam tube temperature, injection pressure, gas composition and so on. In this paper, we give an overview of these systems including a dedicated laser-Raman system as well as several beta-decay activity monitors. We also report on the results of the WGTS demonstrator and other large-scale test experiments giving proof-of-principle that all parameters relevant to the systematics can be controlled and monitored on the 10â3 level or better. As a result of these works, the WGTS systematics can be controlled within stringent margins, enabling the KATRIN experiment to explore the neutrino mass scale with the design sensitivity
First transmission of electrons and ions through the KATRIN beamline
The Karlsruhe Tritium Neutrino (KATRIN) experiment is a large-scale effort to probe the absolute neutrino mass scale with a sensitivity of 0.2 eV (90% confidence level), via a precise measurement of the endpoint spectrum of tritium Ă-decay. This work documents several KATRIN commissioning milestones: the complete assembly of the experimental beamline, the successful transmission of electrons from three sources through the beamline to the primary detector, and tests of ion transport and retention. In the First Light commissioning campaign of autumn 2016, photoelectrons were generated at the rear wall and ions were created by a dedicated ion source attached to the rear section; in July 2017, gaseous 83mKr was injected into the KATRIN source section, and a condensed 83mKr source was deployed in the transport section. In this paper we describe the technical details of the apparatus and the configuration for each measurement, and give first results on source and system performance. We have successfully achieved transmission from all four sources, established system stability, and characterized many aspects of the apparatus
Sensitivity of next-generation tritium beta-decay experiments for keV-scale sterile neutrinos
Recommended from our members
Age-associated B cells predict impaired humoral immunity after COVID-19 vaccination in patients receiving immune checkpoint blockade.
Age-associated B cells (ABC) accumulate with age and in individuals with different immunological disorders, including cancer patients treated with immune checkpoint blockade and those with inborn errors of immunity. Here, we investigate whether ABCs from different conditions are similar and how they impact the longitudinal level of the COVID-19 vaccine response. Single-cell RNA sequencing indicates that ABCs with distinct aetiologies have common transcriptional profiles and can be categorised according to their expression of immune genes, such as the autoimmune regulator (AIRE). Furthermore, higher baseline ABC frequency correlates with decreased levels of antigen-specific memory B cells and reduced neutralising capacity against SARS-CoV-2. ABCs express high levels of the inhibitory FcÎłRIIB receptor and are distinctive in their ability to bind immune complexes, which could contribute to diminish vaccine responses either directly, or indirectly via enhanced clearance of immune complexed-antigen. Expansion of ABCs may, therefore, serve as a biomarker identifying individuals at risk of suboptimal responses to vaccination.This work was funded by the UK Medical Research Council (project number MC_UU_00025/12), the Medical Research Foundation (MRF-057-0002-RG-THAV-C0798) and The Evelyn Trust (grant number 20/40) to JEDT. NJM was supported by the MRC (TSF ref. MR/T032413/1), NHSBT (grant ref. WPA15-02) and Addenbrookeâs Charitable Trust (grant ref. 900239). MAC was supported by the Medical Research Council (project number MC_UU_00025/10). KRP was supported by the Medical Research Council (project number MC_UU_00025/11). KF held an MRC studentship with support from the Cambridge European Trust and St. Johnâs College. KW has received funding by the Deutsche Forschungsgemeinschaft (WA 1597/6-1 and WA 1597/7-1). KW and BK received support by the German Federal Ministry of Education and Research (BMBF) through a grant to the German genetic multi-organ Auto-Immunity Network (GAIN), grant code 01GM2206A. FH is an ERC Advanced Investigator (695669). We thank Carola G. Vinuesa for helpful discussion. The authors also thank the Flow Cytometry Facilities at the MRC-Toxicology Unit, University of Cambridge; Katarzyna Kania from CRUK-CI-Genomics, Cambridge UK for advice on single cell RNA sequencing experiments; and Rosalind Kieran from the Department of Oncology, Cambridge University NHS Hospitals Foundation Trust, Cambridge UK, for contributions for patient recruitment and data collection
External validation of a shortened screening tool using individual participant data meta-analysis: A case study of the Patient Health Questionnaire-Dep-4
Shortened versions of self-reported questionnaires may be used to reduce respondent burden. When shortened screening tools are used, it is desirable to maintain equivalent diagnostic accuracy to full-length forms. This manuscript presents a case study that illustrates how external data and individual participant data meta-analysis can be used to assess the equivalence in diagnostic accuracy between a shortened and full-length form. This case study compares the Patient Health Questionnaire-9 (PHQ-9) and a 4-item shortened version (PHQ-Dep-4) that was previously developed using optimal test assembly methods. Using a large database of 75 primary studies (34,698 participants, 3,392 major depression cases), we evaluated whether the PHQ-Dep-4 cutoff ofâŻâ„âŻ4 maintained equivalent diagnostic accuracy to a PHQ-9 cutoff ofâŻâ„âŻ10. Using this external validation dataset, a PHQ-Dep-4 cutoff ofâŻâ„âŻ4 maximized the sum of sensitivity and specificity, with a sensitivity of 0.88 (95% CI 0.81, 0.93), 0.68 (95% CI 0.56, 0.78), and 0.80 (95% CI 0.73, 0.85) for the semi-structured, fully structured, and MINI reference standard categories, respectively, and a specificity of 0.79 (95% CI 0.74, 0.83), 0.85 (95% CI 0.78, 0.90), and 0.83 (95% CI 0.80, 0.86) for the semi-structured, fully structured, and MINI reference standard categories, respectively. While equivalence with a PHQ-9 cutoff ofâŻâ„âŻ10 was not established, we found the sensitivity of the PHQ-Dep-4 to be non-inferior to that of the PHQ-9, and the specificity of the PHQ-Dep-4 to be marginally smaller than the PHQ-9