754 research outputs found

    Use of a colonoscope for distal duodenal stent placement in patients with malignant obstruction

    Get PDF
    Background: Stent placement in the distal duodenum or proximal jejunum with a therapeutic gastroscope can be difficult, because of the reach of the endoscope, loop formation in the stomach, and flexibility of the gastroscope. The use of a colonoscope may overcome these problems. Objective: To report our experience with distal duodenal stent placement in 16 patients using a colonoscope. Methods: Multicenter, retrospective series of patients with a malignant obstruction at the level of the distal duodenum and proximal jejunum and treated by stent placement using a colonoscope. Main outcome measurements are technical success, ability to eat, complications, and survival. Results: Stent placement was technically feasible in 93% (15/16) of patients. Food intake improved from a median gastric outlet obstruction scoring system (GOOSS) score of 1 (no oral intake) to 3 (soft solids) (p = 0.001). Severe complications were not observed. One patient had persistent obstructive symptoms presumably due to motility problems. Recurrent obstructive symptoms were caused by tissue/tumor ingrowth through the stent mesh [n = 6 (38%)] and stent occlusion by debris [n = 1 (6%)]. Reinterventions included additional stent placement [n = 5 (31%)], gastrojejunostomy [n = 2 (12%)], and endoscopic stent cleansing [n = 1 (6%)]. Median survival was 153 days. Conclusion: Duodenal stent placement can effectively and safely be performed using a colonoscope in patients with an obstruction at the level of the distal duodenum or proximal jejunum. A colonoscope has the advantage that it is long enough and offers good endoscopic stiffness, which avoids looping in the stomach

    Defect symmetry influence on electronic transport of zigzag nanoribbons

    Get PDF
    The electronic transport of zigzag-edged graphene nanoribbon (ZGNR) with local Stone-Wales (SW) defects is systematically investigated by first principles calculations. While both symmetric and asymmetric SW defects give rise to complete electron backscattering region, the well-defined parity of the wave functions in symmetric SW defects configuration is preserved. Its signs are changed for the highest-occupied electronic states, leading to the absence of the first conducting plateau. The wave function of asymmetric SW configuration is very similar to that of the pristine GNR, except for the defective regions. Unexpectedly, calculations predict that the asymmetric SW defects are more favorable to electronic transport than the symmetric defects configuration. These distinct transport behaviors are caused by the different couplings between the conducting subbands influenced by wave function alterations around the charge neutrality point

    Diffractive Dijet Production at sqrt(s)=630 and 1800 GeV at the Fermilab Tevatron

    Get PDF
    We report a measurement of the diffractive structure function FjjDF_{jj}^D of the antiproton obtained from a study of dijet events produced in association with a leading antiproton in pˉp\bar pp collisions at s=630\sqrt s=630 GeV at the Fermilab Tevatron. The ratio of FjjDF_{jj}^D at s=630\sqrt s=630 GeV to FjjDF_{jj}^D obtained from a similar measurement at s=1800\sqrt s=1800 GeV is compared with expectations from QCD factorization and with theoretical predictions. We also report a measurement of the ξ\xi (xx-Pomeron) and β\beta (xx of parton in Pomeron) dependence of FjjDF_{jj}^D at s=1800\sqrt s=1800 GeV. In the region 0.035<ξ<0.0950.035<\xi<0.095, t<1|t|<1 GeV2^2 and β<0.5\beta<0.5, FjjD(β,ξ)F_{jj}^D(\beta,\xi) is found to be of the form β1.0±0.1ξ0.9±0.1\beta^{-1.0\pm 0.1} \xi^{-0.9\pm 0.1}, which obeys β\beta-ξ\xi factorization.Comment: LaTeX, 9 pages, Submitted to Phys. Rev. Letter

    Optical Properties of GaSb Nanofibers

    Get PDF
    Amorphous GaSb nanofibers were obtained by ion beam irradiation of bulk GaSb single-crystal wafers, resulting in fibers with diameters of ~20 nm. The Raman spectra and photoluminescence (PL) of the ion irradiation-induced nanofibers before and after annealing were studied. Results show that the Raman intensity of the GaSb LO phonon mode decreased after ion beam irradiation as a result of the formation of the amorphous nanofibers. A new mode is observed at ~155 cm-1 both from the unannealed and annealed GaSb nanofiber samples related to the A1g mode of Sb–Sb bond vibration. Room temperature PL measurements of the annealed nanofibers present a wide feature band at ~1.4–1.6 eV. The room temperature PL properties of the irradiated samples presents a large blue shift compared to bulk GaSb. Annealed nanofibers and annealed nanofibers with Au nanodots present two different PL peaks (400 and 540 nm), both of which may originate from Ga or O vacancies in GaO. The enhanced PL and new band characteristics in nanostructured GaSb suggest that the nanostructured fibers may have unique applications in optoelectronic devices

    A Study of B0 -> J/psi K(*)0 pi+ pi- Decays with the Collider Detector at Fermilab

    Get PDF
    We report a study of the decays B0 -> J/psi K(*)0 pi+ pi-, which involve the creation of a u u-bar or d d-bar quark pair in addition to a b-bar -> c-bar(c s-bar) decay. The data sample consists of 110 1/pb of p p-bar collisions at sqrt{s} = 1.8 TeV collected by the CDF detector at the Fermilab Tevatron collider during 1992-1995. We measure the branching ratios to be BR(B0 -> J/psi K*0 pi+ pi-) = (8.0 +- 2.2 +- 1.5) * 10^{-4} and BR(B0 -> J/psi K0 pi+ pi-) = (1.1 +- 0.4 +- 0.2) * 10^{-3}. Contributions to these decays are seen from psi(2S) K(*)0, J/psi K0 rho0, J/psi K*+ pi-, and J/psi K1(1270)

    Search for Kaluza-Klein Graviton Emission in ppˉp\bar{p} Collisions at s=1.8\sqrt{s}=1.8 TeV using the Missing Energy Signature

    Get PDF
    We report on a search for direct Kaluza-Klein graviton production in a data sample of 84 pb1{pb}^{-1} of \ppb collisions at s\sqrt{s} = 1.8 TeV, recorded by the Collider Detector at Fermilab. We investigate the final state of large missing transverse energy and one or two high energy jets. We compare the data with the predictions from a 3+1+n3+1+n-dimensional Kaluza-Klein scenario in which gravity becomes strong at the TeV scale. At 95% confidence level (C.L.) for nn=2, 4, and 6 we exclude an effective Planck scale below 1.0, 0.77, and 0.71 TeV, respectively.Comment: Submitted to PRL, 7 pages 4 figures/Revision includes 5 figure

    Measurement of the average time-integrated mixing probability of b-flavored hadrons produced at the Tevatron

    Get PDF
    We have measured the number of like-sign (LS) and opposite-sign (OS) lepton pairs arising from double semileptonic decays of bb and bˉ\bar{b}-hadrons, pair-produced at the Fermilab Tevatron collider. The data samples were collected with the Collider Detector at Fermilab (CDF) during the 1992-1995 collider run by triggering on the existence of μμ\mu \mu and eμe \mu candidates in an event. The observed ratio of LS to OS dileptons leads to a measurement of the average time-integrated mixing probability of all produced bb-flavored hadrons which decay weakly, χˉ=0.152±0.007\bar{\chi} = 0.152 \pm 0.007 (stat.) ±0.011\pm 0.011 (syst.), that is significantly larger than the world average χˉ=0.118±0.005\bar{\chi} = 0.118 \pm 0.005.Comment: 47 pages, 10 figures, 15 tables Submitted to Phys. Rev.

    Search for lepton flavor violating decays of a heavy neutral particle in p-pbar collisions at root(s)=1.8 TeV

    Get PDF
    We report on a search for a high mass, narrow width particle that decays directly to e+mu, e+tau, or mu+tau. We use approximately 110 pb^-1 of data collected with the Collider Detector at Fermilab from 1992 to 1995. No evidence of lepton flavor violating decays is found. Limits are set on the production and decay of sneutrinos with R-parity violating interactions.Comment: Figure 2 fixed. Reference 4 fixed. Minor changes to tex
    corecore