11,383 research outputs found

    "Market Processes and Thwarting Systems"

    Get PDF
    This paper suggests that there are two longstanding views on business cycles and economic dynamics: One emphasizes endogenous stability plus exogenous disturbances, while the other focuses on endogenous instability plus institutional 'containing' or "thwarting" mechanisms. The latter tradition regards business cycles and economic instability as the natural and inherent consequence of self-interest-motivated behavior in complex economies with sophisticated financial institutions. In fact, it is the interaction between the system's endoge-nous dynamics and the effects of institutions and interventions which, if "apt," constrains the outcomes of capitalist market processes to acceptable outcomes. The endogenous instability view of the economy, in which institutional structures and interventions stabilize the fragile, essentially refutes Lucas: He asserts that the economy is a mechanism that transforms exogenous shocks (either random or unanticipated policy interventions) into business cycles, thus generating a growth equilibrium. Recent history has illustrated the flaws of laissez-faire theory as the postwar capitalist economies that have enjoyed consistently high levels of growth are big government interventionist economies. The challenge for the future is recognizing that market processes are deficient not only in their ability to maintain aggregate demand, but also as devices for assuring productive investment and a tolerable distribution of income.

    Methodology for Three Dimensional Nozzle Design

    Get PDF
    Criteria for the selection and methods of analysis for designing a hypersonic scramjet nozzle are discussed. The criteria are based on external and internal flow requirements, related to drag, lift, and pitching moments of the vehicle and thrust of the engine. The steps involved in establishing the criteria are analyzed. Mathematical models of the design procedure are provided

    Numerical program for analysis of three-dimensional supersonic exhaust flow fields (CHAR 3D)

    Get PDF
    Choice of reference plane orientation depends on specific nozzle geometry, with different configurations requiring different reference plane systems. In addition, for given configuration several reference systems may be used in different regions of flow field, so each system is locally aligned with flow

    Force to Debond Brackets from High-fusing and Low-fusing Porcelain Systems

    Get PDF
    The purpose of this study was to test the hypothesis that porcelain surface finishing, ie, low- and high-fusing porcelain, has an effect on the amount of force required to debond orthodontic brackets. A total of 20 high-fusing and 20 low-fusing porcelain specimens were prepared, polished, and bonded with standard edgewise brackets using a suggested porcelain bonding protocol. The brackets were debonded with a universal testing machine at shear mode. Resin removal was performed using two methods: a multifluted carbide bur with and without the use of Sof-Lex polishing discs. Representative specimens were studied under a scanning electron microscope before and after debonding to assess the surface morphology and potential surface damage. Statistical analysis with a t-test revealed that there was no difference between the two porcelain treatments on the force to debond values and no qualitative differences were observed on the porcelain surface between the two resin clean-up methods. From a clinical perspective, the practitioner can bond ceramic restorations without previous knowledge of the porcelain type used

    Helping carers to care: the 10/66 dementia research group's randomized control trial of a caregiver intervention in Peru

    Get PDF
    OBJECTIVE There is a need, in the absence of formal services, to design interventions aimed at improving the lives of people with dementia and their families. This study tested the effectiveness of the 10/66 caregiver intervention among people with dementia and their caregivers in Lima, Peru. METHOD Design/participants: a randomized controlled trial was performed involving 58 caregivers of people with dementia that received the intervention in the beginning of the trial (n = 29) or six months later (n = 29). The intervention consisted of three modules: 1) assessment (one session); 2) basic education about dementia (two sessions); and 3) training regarding specific problem behaviors (two sessions). Main outcome measures: Caregivers and patients with dementia were assessed at baseline and after six months. For caregivers, the measures included strain (Zarit Burden Interview), psychological distress (SRQ-20), and quality of life (WHOQOL-BREF). Dementia patients completed scales assessing behavioral and psychological symptoms (NPI-Q) and quality of life (DEMQOL). RESULTS Caregivers in the intervention group reported significantly decreased strain measures six months after the intervention compared to controls. No group differences were found in respect to the caregivers' psychological distress and to quality of life in both caregivers and patients. CONCLUSION The 10/66 intervention seems to be as effective as similar interventions used in more developed countries

    The CMS Electromagnetic Calorimeter Pre-calibration with Cosmic Rays and Test Beam Electrons

    Get PDF
    The electromagnetic calorimeter of the CMS experiment at the new CERN proton-proton Collider (LHC) is at an advanced stage of construction. A necessary condition for its optimal performance is a precise channel-to-channel calibration. The use of cosmic rays allows the pre-calibration of all the channels at the level of 2% before the final installation in CMS and provides an extensive functionality test, essential for the commissioning of the detector. On the other hand, a beam of electrons permits extremely precise (better than 0.5%) pre-calibration coefficients to be obtained on a fraction of the calorimeter, that can also be used as a reference for the in situ calibration procedures that will rely on physics data

    Normalized ghost imaging

    Get PDF
    We present an experimental comparison between different iterative ghost imaging algorithms. Our experimental setup utilizes a spatial light modulator for generating known random light fields to illuminate a partially-transmissive object. We adapt the weighting factor used in the traditional ghost imaging algorithm to account for changes in the efficiency of the generated light field. We show that our normalized weighting algorithm can match the performance of differential ghost imaging

    Examining antecedents and consequences of perceived-service-quality in the hotel industry: a comparison between London and New York

    Get PDF
    Purpose The paper aims at exploring the relations among the concepts of customer-relationship-management, convenience, trust, perceived-service-quality, satisfaction, perceived value, loyalty, image and purchase-intention in the hotel sector. Design/methodology/approach The research was conducted using interviews with hospitality managers and guests who had a direct connection with the hotel industry. According to our qualitative study results and literature review, we designed a model which was examined via structural-equation-modelling (SEM) and fuzzy-set qualitative comparative analysis. Findings Our paper presents a conceptual framework which enhances existing research in the field of study, as it was implemented to measure the antecedent and consequences of perceived-service-quality. Based on the results from NY and London, we found customer relationship management and convenience have significant impact on perceived-service-quality. Interestingly the aggregated data illustrates the negative relationship between image, loyalty, and purchase intention. Originality The approach used by the current study is partially in line with previous theoretical analyses and shows appealing patterns in international service-quality perception. Besides, the paper adds insights into the realm, linking together different dimensions in order to reach an in-depth understanding and complex analysis of each item that affects and is affected by perceived-service-quality in the hotel industry

    On-line luminosity measurements at LEP

    Get PDF
    At each LEP interaction point, the luminosity is measured on-line by small angle Bhabha monitors. These monitors are optimized to observe in all bunches relative luminosity changes in a few seconds. The description of the detectors is given, together with the method used to calculate the luminosity after background correction. Optimization of the LEP performances was done with beam separation scans using the luminosity measurements. Those scans also provide a unique measurement of the vertical beam size at the interaction point

    Critical Temperature tuning of Ti/TiN multilayer films suitable for low temperature detectors

    Full text link
    We present our current progress on the design and test of Ti/TiN Multilayer for use in Kinetic Inductance Detectors (KIDs). Sensors based on sub-stoichiometric TiN film are commonly used in several applications. However, it is difficult to control the targeted critical temperature TCT_C, to maintain precise control of the nitrogen incorporation process and to obtain a production uniformity. To avoid these problems we investigated multilayer Ti/TiN films that show a high uniformity coupled with high quality factor, kinetic inductance and inertness of TiN. These features are ideal to realize superconductive microresonator detectors for astronomical instruments application but also for the field of neutrino physics. Using pure Ti and stoichiometric TiN, we developed and tested different multilayer configuration, in term of number of Ti/TiN layers and in term of different interlayer thicknesses. The target was to reach a critical temperature TCT_C around (1Ă·1.5)(1\div 1.5) K in order to have a low energy gap and slower recombination time (i.e. low generation-recombination noise). The results prove that the superconductive transition can be tuned in the (0.5Ă·4.6)(0.5\div 4.6) K temperature range properly choosing the Ti thickness in the (0Ă·15)(0\div 15) nm range, and the TiN thickness in the (5Ă·100)(5\div 100) nm rang
    • …
    corecore