63 research outputs found

    U-PHOS Project: Development of a Large Diameter Pulsating Heat Pipe Experiment on board REXUS 22

    Get PDF
    U-PHOS Project aims to analyse and characterise the behaviour of a large diameter Pulsating Heat Pipe (PHP) on board REXUS 22 sounding rocket. A PHP is a passive thermal control device consisting of a serpentine capillary tube, evacuated, partially filled with a working fluid and finally sealed. In this configuration, the liquid and vapour phases are randomly distributed in the form of liquid slugs and vapour plugs. The heat is efficiently transported by means of the self-sustained oscillatory fluid motion driven by the phase change phenomena. On ground conditions, a small diameter is required in order to obtain a confined slug flow regime. In milli-gravity conditions, buoyancy forces become less intense and the PHP diameter may be increased still maintaining the slug/plug flow configuration typical of the PHP operation. Consequently, the PHP heat power capability may be increased too. U-PHOS aims at proving that a Large Diameter PHP effectively works in milli-g conditions by characterizing its thermal response during a sounding rocket flight. The actual PHP tube is made of aluminum (3 mm inner diameter, filled with FC-72), heated at the evaporator by a compact electrical resistance, cooled at the condenser by a Phase Change Material (PCM) embedded in a metallic foam. The tube wall temperatures are recorded by means of Fibre Bragg Grating (FBG) sensors; the local fluid pressure is acquired by means of a pressure transducer. The present work intends to report the actual status of the project, focusing in particular on the experiment improvements with respect to the previous campaign

    Upgraded Pulsating Heat Pipe Only For Space (U-Phos): Results of the 22nd Rexus Sounding Rocket Campaign

    Get PDF
    A large tube may still behave, to a certain extent, as a capillary in a micro-gravity environment. This very basic concept is here applied to a two-phase passive heat transfer devices in order to obtain a new family of hybrid wickless heat pipes. Indeed, a Loop Thermosyphon, which usually consists of a large tube, closed end to end in a loop, evacuated and partially filled with a working fluid and intrinsically gravity assisted, may become a capillary tube in space condition and turn its thermo-fluidic behavior into a so called Pulsating Heat Pipe (PHP), or better, a Space Pulsating Heat Pipe (SPHP). Since the objective of the present work is to experimentally demonstrate the feasibility of such a hybrid device, a SPHP has been designed, built, instrumented and tested both on ground and microgravity conditions on the 22nd ESA REXUS Sounding Rocket Campaign. Ground tests demonstrate that the device effectively work as a gravity assisted loop thermosyphon, whether the sounding rocket data clearly reveal a change in the thermal hydraulic behavior very similar to the PHP. Since a microgravity period of approximately 120s is not sufficient to reach a pseudo steady state regime, further investigation on a longer term weightless condition is mandatory

    Off–label long acting injectable antipsychotics in real–world clinical practice: a cross-sectional analysis of prescriptive patterns from the STAR Network DEPOT study

    Get PDF
    Introduction: Information on the off–label use of Long–Acting Injectable (LAI) antipsychotics in the real world is lacking. In this study, we aimed to identify the sociodemographic and clinical features of patients treated with on– vs off–label LAIs and predictors of off–label First– or Second–Generation Antipsychotic (FGA vs. SGA) LAI choice in everyday clinical practice. Method: In a naturalistic national cohort of 449 patients who initiated LAI treatment in the STAR Network Depot Study, two groups were identified based on off– or on–label prescriptions. A multivariate logistic regression analysis was used to test several clinically relevant variables and identify those associated with the choice of FGA vs SGA prescription in the off–label group. Results: SGA LAIs were more commonly prescribed in everyday practice, without significant differences in their on– and off–label use. Approximately 1 in 4 patients received an off–label prescription. In the off–label group, the most frequent diagnoses were bipolar disorder (67.5%) or any personality disorder (23.7%). FGA vs SGA LAI choice was significantly associated with BPRS thought disorder (OR = 1.22, CI95% 1.04 to 1.43, p = 0.015) and hostility/suspiciousness (OR = 0.83, CI95% 0.71 to 0.97, p = 0.017) dimensions. The likelihood of receiving an SGA LAI grew steadily with the increase of the BPRS thought disturbance score. Conversely, a preference towards prescribing an FGA was observed with higher scores at the BPRS hostility/suspiciousness subscale. Conclusion: Our study is the first to identify predictors of FGA vs SGA choice in patients treated with off–label LAI antipsychotics. Demographic characteristics, i.e. age, sex, and substance/alcohol use co–morbidities did not appear to influence the choice towards FGAs or SGAs. Despite a lack of evidence, clinicians tend to favour FGA over SGA LAIs in bipolar or personality disorder patients with relevant hostility. Further research is needed to evaluate treatment adherence and clinical effectiveness of these prescriptive patterns

    Comparing Long-Acting Antipsychotic Discontinuation Rates Under Ordinary Clinical Circumstances: A Survival Analysis from an Observational, Pragmatic Study

    Get PDF
    Background: Recent guidelines suggested a wider use of long-acting injectable antipsychotics (LAI) than previously, but naturalistic data on the consequences of LAI use in terms of discontinuation rates and associated factors are still sparse, making it hard for clinicians to be informed on plausible treatment courses. Objective: Our objective was to assess, under real-world clinical circumstances, LAI discontinuation rates over a period of 12 months after a first prescription, reasons for discontinuation, and associated factors. Methods: The STAR Network ‘Depot Study’ was a naturalistic, multicentre, observational prospective study that enrolled subjects initiating a LAI without restrictions on diagnosis, clinical severity or setting. Participants from 32 Italian centres were assessed at baseline and at 6 and 12 months of follow-up. Psychopathology, drug attitude and treatment adherence were measured using the Brief Psychiatric Rating Scale, the Drug Attitude Inventory and the Kemp scale, respectively. Results: The study followed 394 participants for 12 months. The overall discontinuation rate at 12 months was 39.3% (95% confidence interval [CI] 34.4–44.3), with paliperidone LAI being the least discontinued LAI (33.9%; 95% CI 25.3–43.5) and olanzapine LAI the most discontinued (62.5%; 95% CI 35.4–84.8). The most frequent reason for discontinuation was onset of adverse events (32.9%; 95% CI 25.6–40.9) followed by participant refusal of the medication (20.6%; 95% CI 14.6–27.9). Medication adherence at baseline was negatively associated with discontinuation risk (hazard ratio [HR] 0.853; 95% CI 0.742–0.981; p = 0.026), whereas being prescribed olanzapine LAI was associated with increased discontinuation risk compared with being prescribed paliperidone LAI (HR 2.156; 95% CI 1.003–4.634; p = 0.049). Conclusions: Clinicians should be aware that LAI discontinuation is a frequent occurrence. LAI choice should be carefully discussed with the patient, taking into account individual characteristics and possible obstacles related to the practicalities of each formulation

    The Role of Attitudes Toward Medication and Treatment Adherence in the Clinical Response to LAIs: Findings From the STAR Network Depot Study

    Get PDF
    Background: Long-acting injectable (LAI) antipsychotics are efficacious in managing psychotic symptoms in people affected by severe mental disorders, such as schizophrenia and bipolar disorder. The present study aimed to investigate whether attitude toward treatment and treatment adherence represent predictors of symptoms changes over time. Methods: The STAR Network \u201cDepot Study\u201d was a naturalistic, multicenter, observational, prospective study that enrolled people initiating a LAI without restrictions on diagnosis, clinical severity or setting. Participants from 32 Italian centers were assessed at three time points: baseline, 6-month, and 12-month follow-up. Psychopathological symptoms, attitude toward medication and treatment adherence were measured using the Brief Psychiatric Rating Scale (BPRS), the Drug Attitude Inventory (DAI-10) and the Kemp's 7-point scale, respectively. Linear mixed-effects models were used to evaluate whether attitude toward medication and treatment adherence independently predicted symptoms changes over time. Analyses were conducted on the overall sample and then stratified according to the baseline severity (BPRS < 41 or BPRS 65 41). Results: We included 461 participants of which 276 were males. The majority of participants had received a primary diagnosis of a schizophrenia spectrum disorder (71.80%) and initiated a treatment with a second-generation LAI (69.63%). BPRS, DAI-10, and Kemp's scale scores improved over time. Six linear regressions\u2014conducted considering the outcome and predictors at baseline, 6-month, and 12-month follow-up independently\u2014showed that both DAI-10 and Kemp's scale negatively associated with BPRS scores at the three considered time points. Linear mixed-effects models conducted on the overall sample did not show any significant association between attitude toward medication or treatment adherence and changes in psychiatric symptoms over time. However, after stratification according to baseline severity, we found that both DAI-10 and Kemp's scale negatively predicted changes in BPRS scores at 12-month follow-up regardless of baseline severity. The association at 6-month follow-up was confirmed only in the group with moderate or severe symptoms at baseline. Conclusion: Our findings corroborate the importance of improving the quality of relationship between clinicians and patients. Shared decision making and thorough discussions about benefits and side effects may improve the outcome in patients with severe mental disorders

    Muscular pattern in patients with temporomandibular joint disc displacement with reduction: an electromyographical assessment

    Get PDF
    Objective: Surface Electromyography of masticatory muscles (sEMG) is used as a tool to support diagnosis and treatment of Temporomandibular disorders (TMDs). The study aimed at examining jaw muscles pattern in individuals with temporomandibular joint disc displacement with reduction (TMJ/DDR). This sort of subjects was supposed to have a different muscular pattern compared to the control group. Materials and methods: Sixty-four women with unilateral TMJ/DDR and forty TMD-free women underwent a sEMG assessment of masticatory muscles. Descriptive statistics were performed. Student T-Test assessed differences between the two groups. Statistical significance was set at ρ < 0.05. Result: The t-test showed statistically significant results only in BAR and SMI scores (ρ value < 0,0001). The other measurements did not differ between the two groups. BAR index values of all healthy subjects were within the reference range. Almost the entire TMJ/DDR group had BAR index out of reference range and anteriorly placed. Conclusion: Women with TMJ/DDR showed an altered recruitment of the jaw muscles, with significant difference between the activity of the couple of temporalis and the one of masseters, compared to the control group. A lower chewing efficiency was found in the DDR group compared to the control one

    Atmospheric propellant fed Hall thruster discharges: 0D-hybrid model and experimental results

    No full text
    As part of on-going efforts in advancing air-breathing electric propulsion, the HT5k Hall thruster was characterized in six operating conditions, ranging from 5 mg s(-1) to 7 mg s(-1) of 0.56N(2) + 0.44O(2) mass flow rate and 225 V to 300 V of discharge voltage. The cathode was operated with N-2 at mass flow rates between 0.5 mg s(-1) and 0.7 mg s(-1). This paper presents a 0D-hybrid model for atmospheric propellant fed Hall thruster discharges. Verified performance ranged between 30 mN to 120 mN in thrust, 1.2 kW to 5.2 kW in discharge power, and 8% to 18% in anodic efficiency. Calibrated model comparison against experimental data resulted in a mean absolute error of 3.7% in thrust and 7.6% in discharge power

    Rarefied Flow Simulation of Conical Intake and Plasma Thruster for Very Low Earth Orbit Spaceflight

    No full text
    Air-breathing electric propulsion has the potential to enable space missions at very low altitudes. This study introduces to a 0D hybrid formulation for describing the coupled intake and thruster physics of an air-breathing electric propulsion prototype. Model derivation is then used to formally derive main system’s key performance indicators and estimate the figure of merit for the design of rarefied flow air intakes. Achievable performance by conical intake shapes are defined and evaluated by Monte Carlo simulations. Influence of inlet flow variation is assessed by dedicated sensitivity analyses. The set of requirements and optimality conditions derived for the downstream plasma thruster suggest concept feasibility within an achievable performance range

    Gnathological and osteopathic treatments with digital evaluations before and after therapies: a case report of a patient with Ehlers-Danlos syndrome

    No full text
    Background. Ehlers-Danlos syndromes (EDS) are inherited connective tissue disorders, requiring specific care along with a multidisciplinary approach by an expert medical staff, as for both the diagnosis and the treatment management. Chronic generalized pain and musculoskeletal dysfunctions due to joint hypermobility are common traits. Temporomandibular disorders (TMDs) are among the most frequent complaints. The authors report the diagnostic and therapeutic management of an EDS subject. Case presentation. A 33-year old woman with Ehlers-Danlos syndrome, hypermobile type, was clinically evaluated and treated. She underwent a gnathological therapy with an anterior repositioning splint and proprioception exercises, and a physical rehabilitation through an osteopathic manipulation treatment (OMT). Technology - surface Electromyography (sEMG) of masticatory muscles, T-scan and stabilometric platform- supported diagnostic and therapeutic phases, giving objective and quantifiable information on the patient's assessment before and after treatments. Conclusion. According to a targeted therapeutic strategy, both the gnathological and the osteopathic therapy proved to be effective in improving patient's symptomatology and functionality, as confirmed by digital findings
    • 

    corecore