1,973 research outputs found
Quantum size effects on the perpendicular upper critical field in ultra-thin lead films
We report the thickness-dependent (in terms of atomic layers) oscillation
behavior of the perpendicular upper critical field in the
ultra-thin lead films at the reduced temperature (). Distinct
oscillations of the normal-state resistivity as a function of film thickness
have also been observed. Compared with the oscillation, the
shows a considerable large oscillation amplitude and a phase shift. The
oscillatory mean free path caused by quantum size effect plays a role in
oscillation.Comment: 4 pages, 4 figure
Co
Different loading rates of photocatalysts Co3O4/C3N4 were prepared by calcination method. Their photocatalytic performances were evaluated by the degradation of methyl blue under visible light irradiation. The results show that the introduction of Co3O4 significantly improves the optical absorption properties of C3N4, which is beneficial to the separation of photogenerated electrons and holes on the surface of catalyst. The prepared Co3O4/C3N4 for visible photocatalytic degradation of methyl blue has higher catalytic efficiency than that of pure C3N4 or pure Co3O4. The best cobalt loading rate was 30% when the concentration of methylene blue was 40 mg/L. Recycling rate of 30% Co3O4/C3N4 composite catalyst was studied. After 4 cycles, the degradation rate was only slightly decreased from 86.8% to 82.8%, indicating the catalyst with good photostability and repeatability.nbs
Recommended from our members
Elucidating the Limit of Li Insertion into the Spinel Li4Ti5O12
In this work, we show that the well-known lithium-ion anode material, Li4Ti5O12, exhibits exceptionally high initial capacity of 310 mAh g-1 when it is discharged to 0.01 V. It maintains a reversible capacity of 230 mAh g-1, far exceeding the "theoretical" capacity of 175 mAh g-1 when this anode is lithiated to the composition Li7Ti5O12. Neutron diffraction analyses identify that additional Li reversibly enters into the Li7Ti5O12 to form Li8Ti5O12. density functional theory (DFT) calculations reveal the average potentials of the Li4Ti5O12 to Li7Ti5O12 step and the Li7Ti5O12 to Li8Ti5O12 step are 1.57 and 0.19 V, respectively, which are in excellent agreement with experimental results. Transmission electron microscopy (TEM) studies confirm that the irreversible capacity of Li4Ti5O12 during its first cycle originates from the formation of a solid electrolyte interface (SEI) layer. This work clarifies the fundamental lithiation mechanism of the Li4Ti5O12, when lithiated to 0.01 V vs Li
Integrated Care of Atrial Fibrillation Using the ABC (Atrial fibrillation Better Care) Pathway Improves Clinical Outcomes in Chinese Population: An Analysis From the Chinese Atrial Fibrillation Registry
Background: "Atrial fibrillation Better Care" (ABC) pathway has been proposed to improve the management of patients suffered from atrial fibrillation (AF). This integrated or holistic management approach comprise of three aspects, including "A" Avoid stroke or Anticoagulation; "B" Better symptom control with rate or rhythm control strategies; "C" Cardiovascular risk factor and Concomitant diseases management. We aimed to confirm the beneficial evidence of ABC pathway compliance in a Chinese AF cohort. Method and Results: From the Chinese Atrial Fibrillation registry (CAFR) dataset, a total of 19,187 non-valvular AF patients were enrolled, of which 4.365 (22.8%) were ABC pathway compliant (ABC compliance group). During a median follow-up of 4.1 ± 1.8 years, The incident rate of all-cause death in ABC compliance group and non-ABC compliance group is 2.7 and 1.1 per 100 person-year (p p p Conclusion: In a large cohort of Chinese AF patients, ABC pathway compliance shows an independently association with reduction of all-cause death and composite outcome of all-cause death, ischemic stroke and intracranial hemorrhage. Better compliance of ABC integrated care contributes to lower HR for adverse events
The DArk Matter Particle Explorer mission
The DArk Matter Particle Explorer (DAMPE), one of the four scientific space
science missions within the framework of the Strategic Pioneer Program on Space
Science of the Chinese Academy of Sciences, is a general purpose high energy
cosmic-ray and gamma-ray observatory, which was successfully launched on
December 17th, 2015 from the Jiuquan Satellite Launch Center. The DAMPE
scientific objectives include the study of galactic cosmic rays up to
TeV and hundreds of TeV for electrons/gammas and nuclei respectively, and the
search for dark matter signatures in their spectra. In this paper we illustrate
the layout of the DAMPE instrument, and discuss the results of beam tests and
calibrations performed on ground. Finally we present the expected performance
in space and give an overview of the mission key scientific goals.Comment: 45 pages, including 29 figures and 6 tables. Published in Astropart.
Phy
Direct detection of a break in the teraelectronvolt cosmic-ray spectrum of electrons and positrons
High energy cosmic ray electrons plus positrons (CREs), which lose energy
quickly during their propagation, provide an ideal probe of Galactic
high-energy processes and may enable the observation of phenomena such as
dark-matter particle annihilation or decay. The CRE spectrum has been directly
measured up to TeV in previous balloon- or space-borne experiments,
and indirectly up to TeV by ground-based Cherenkov -ray
telescope arrays. Evidence for a spectral break in the TeV energy range has
been provided by indirect measurements of H.E.S.S., although the results were
qualified by sizeable systematic uncertainties. Here we report a direct
measurement of CREs in the energy range by the
DArk Matter Particle Explorer (DAMPE) with unprecedentedly high energy
resolution and low background. The majority of the spectrum can be properly
fitted by a smoothly broken power-law model rather than a single power-law
model. The direct detection of a spectral break at TeV confirms the
evidence found by H.E.S.S., clarifies the behavior of the CRE spectrum at
energies above 1 TeV and sheds light on the physical origin of the sub-TeV
CREs.Comment: 18 pages, 6 figures, Nature in press, doi:10.1038/nature2447
Effective combinatorial immunotherapy for penile squamous cell carcinoma
Penile squamous cell carcinoma (PSCC) accounts for over 95% of penile malignancies and causes significant mortality and morbidity in developing countries. Molecular mechanisms and therapies of PSCC are understudied, owing to scarcity of laboratory models. Herein, we describe a genetically engineered mouse model of PSCC, by co-deletion of Smad4 and Apc in the androgen-responsive epithelium of the penis. Mouse PSCC fosters an immunosuppressive microenvironment with myeloid-derived suppressor cells (MDSCs) as a dominant population. Preclinical trials in the model demonstrate synergistic efficacy of immune checkpoint blockade with the MDSC-diminishing drugs cabozantinib or celecoxib. A critical clinical problem of PSCC is chemoresistance to cisplatin, which is induced by Pten deficiency on the backdrop of Smad4/Apc co-deletion. Drug screen studies informed by targeted proteomics identify a few potential therapeutic strategies for PSCC. Our studies have established what we believe to be essential resources for studying PSCC biology and developing therapeutic strategies
Intravenous leiomyomatosis of the uterus with extension to the right heart
A 42-year-old woman admitted with debilitation and engorgement both lower extremities. Transthoracic two-dimensional echocardiography, abdominal ultrasound and computerized tomography revealed a lobulated pelvic mass, a mass within right internal iliac vein, both common iliac vein, as well as the inferior vena cava, extending into the right atrium. In addition, echocardiography and abdominal ultrasound showed the tumor of right atrium and inferior vena cave has no stalk and has well-demarcated borders with the wall of right atrium and inferior vena cave. Hence, the presumptive diagnosis of IVL was made by echocardiography and abdominal ultrasound and the presumptive diagnosis of sarcoma with invasion in right internal iliac vein, both common iliac vein, the inferior vena cava, as well as the right atrium was made by multi-detector-row computerized tomography. The patient underwent a one-stage combined multidisciplinary thoraco-abdominal operation under general anaesthetic. Subsequently the pathologic report confirmed IVL
\psi(2S) Decays into \J plus Two Photons
Using \gamma \gamma J/\psi, J/\psi \ra e^+ e^- and events
from a sample of \psip decays collected with the BESII
detector, the branching fractions for \psip\ra \pi^0\J, \eta\J, and
\psi(2S)\ar\gamma\chi_{c1},\gamma\chi_{c2}\ar\gamma\gamma\jpsi are measured
to be B(\psip\ra \pi^0\J) = (1.43\pm0.14\pm0.13)\times 10^{-3}, B(\psip\ra
\eta\J) = (2.98\pm0.09\pm0.23)%,
B(\psi(2S)\ar\gamma\chi_{c1}\ar\gamma\gamma\jpsi) = (2.81\pm0.05\pm 0.23)%,
and B(\psi(2S)\ar\gamma\chi_{c2}\ar\gamma\gamma\jpsi) = (1.62\pm0.04\pm
0.12)%.Comment: 7 pages, 6 figures. submitted to Phys. Rev.
- …