185 research outputs found

    A DIC based technique to measure the contraction of a skeletal muscle engineered tissue

    Get PDF
    Tissue engineering is a multidisciplinary science based on the application of engineering approaches to biologic tissue formation. Engineered tissue internal organization represents a key aspect to increase biofunctionality before transplant and, as regarding skeletal muscles, the potential of generating contractile forces is dependent on the internal fiber organization and is reflected by some macroscopic parameters, such as the spontaneous contraction. Here we propose the application of digital image correlation (DIC) as an independent tool for an accurate and noninvasive measurement of engineered muscle tissue spontaneous contraction. To validate the proposed technique we referred to the X-MET, a promising 3-dimensional model of skeletal muscle. The images acquired through a high speed camera were correlated with a custom-made algorithm and the longitudinal strain predictions were employed for measuring the spontaneous contraction. The spontaneous contraction reference values were obtained by studying the force response.The relative error between the spontaneous contraction frequencies computed in both ways was always lower than 0.15%. In conclusion, the use of a DIC based systemallows for an accurate and noninvasive measurement of biological tissues’ spontaneous contraction, in addition to the measurement of tissue strain field on any desired region of interest during electrical stimulation

    Study of the preanalytical variables affecting the measurement of clinically relevant free-circulating microRNAs: focus on sample matrix, platelet depletion, and storage conditions

    Get PDF
    Introduction: Circulating microRNAs (miRNAs) are emerging as potential biomarkers. However, the lack of preanalytical and analytical standardization limits their use. The aim of this study was to determine the expression of different miRNAs in plasma according to different collection and storage conditions. Materials and methods: Venous blood from 10 volunteers was collected in tubes spray-coated with dipotassium salt of ethylendiaminetetraacetic acid, either with (plasma-preparation tube, PPT) or without (K2EDTA) gel separator. Platelet-poor plasma (PPP) was also obtained from K2EDTA plasma. After storage under different conditions, miRNA-enriched total RNA was isolated from plasma and reverse transcribed. A panel of 179 miRNAs was assayed by quantitative polymerase chain reaction and the results were analysed by GenEx software. Detectability and stability of miRNAs were determined. Results: The number of undetected miRNAs was: 18, 24, and 22 in PPT; 83, 43, and 20 in K2EDTA; and 76, 106, and 104 in PPP samples, for plasma immediately frozen at - 80°C and plasma stored for 24h at room temperature or 4°C, respectively. Circulating miRNA expression in PPT samples was not affected by storage delay or temperature, while the percentage of up- and down-regulated miRNA in K2EDTA and PPP samples ranged from 2%, and 1% to 7%, and 5%, respectively. Conclusions: Sample matrix, temperature and delay in storage strongly influence the expression level of plasma miRNAs. Our results indicate PPT tubes as the most suitable matrix to improve total miRNA detectability and stability, independently of temperature

    Swept-source OCT reduces the risk of axial length measurement errors in eyes with cataract and epiretinal membranes

    Get PDF
    Aims: To compare the biometric data from partial coherence interferometry (PCI) and swept-source OCT (SS-OCT) in patients with age-related cataract and epiretinal membrane (ERM): ERM, ERM with foveoschisis and macular pseudohole. Methods: 49 eyes of 49 subjects including 36 ERM, 9 ERM foveoschisis and 4 macular pseudohole were analysed to evaluate the axial length (AL) measurements and the presence of AL measurement errors, defined basing on the shape of the biometric output graphs and on the concordance of AL values between instruments. Eyes with ERM were divided in four stages according to OCT features (i.e. presence/absence of the foveal pit, presence of ectopic inner foveal layers, disrupted retinal layers). Results: The devices provided similar mean AL measurements in all subgroups, with differences <0.1 mm in 41/49 cases (83.6%). AL measurement errors were observed in ERM stages 3 and 4, characterized by ectopic inner foveal layers, and were significantly more frequent with the PCI (8/17, 47%) as compared with the SS-OCT device (2/17, 12%), p = 0.02. The refractive prediction error in cases with AL measurement errors was significantly greater using the PCI compared to the SS-OCT device (p<0.05). Conclusion: Both devices provide reliable biometric data in the majority of patients and can be used in the preoperative assessment of patients with age-related cataract and ERM. In eyes with ectopic inner foveal layers, attention should be paid as AL measurement and refractive prediction errors may occur, more frequently with the PCI device

    Differences in osteoimmunological biomarkers predictive of psoriatic arthritis among a large Italian cohort of psoriatic patients

    Get PDF
    (1) Background: In literature it is reported that 20\u201330% of psoriatic patients evolve to psoriatic arthritis over time. Currently, no specific biochemical markers can either predict progression to psoriatic arthritis or response to therapies. This study aimed to identify osteoimmunological markers applicable to clinical practice, giving a quantitative tool for evaluating pathological status and, eventually, to provide prognostic support in diagnosis. (2) Methods: Soluble (serum) bone and cartilage markers were quantified in 50 patients with only psoriasis, 50 psoriatic patients with psoriatic arthritis, and 20 healthy controls by means of multiplex and enzyme-linked immunoassays. (3) Results: Differences in the concentrations of matrix metalloproteases (MMPs), tissue inhibitors of metalloproteinases (TIMPs), receptor activator of nuclear factor kappa-B-ligand (RANK-L), procollagen type I N propeptide (PINP), C-terminal telopeptide of type I collagen (CTx-I), dickkopf-related protein 1 (DKK1), and sclerostin (SOST) distinguished healthy controls from psoriasis and psoriatic arthritis patients. We found that MMP2, MMP12, MMP13, TIMP2, and TIMP4 distinguished psoriasis from psoriatic arthritis patients undergoing a systemic treatment, with a good diagnostic accuracy (Area under the ROC Curve (AUC) > 0.7). Then, chitinase-3-like protein 1 (CHI3L1) and MMP10 distinguished psoriasis from psoriatic arthritis not undergoing systemic therapy and, in the presence of onychopathy, MMP8 levels were higher in psoriasis than in psoriatic arthritis. However, in these latter cases, the diagnostic accuracy of the identified biomarkers was low (0.5 < AUC < 0.7). (4) Conclusions. By highlighting never exploited differences, the wide osteoimmunological biomarkers panel provides a novel clue to the development of diagnostic paths in psoriasis and psoriasis-associated arthropathic disease

    A DIC Based Technique to Measure the Contraction of a Skeletal Muscle Engineered Tissue

    Get PDF
    Tissue engineering is a multidisciplinary science based on the application of engineering approaches to biologic tissue formation. Engineered tissue internal organization represents a key aspect to increase biofunctionality before transplant and, as regarding skeletal muscles, the potential of generating contractile forces is dependent on the internal fiber organization and is reflected by some macroscopic parameters, such as the spontaneous contraction. Here we propose the application of digital image correlation (DIC) as an independent tool for an accurate and noninvasive measurement of engineered muscle tissue spontaneous contraction. To validate the proposed technique we referred to the X-MET, a promising 3-dimensional model of skeletal muscle. The images acquired through a high speed camera were correlated with a custom-made algorithm and the longitudinal strain predictions were employed for measuring the spontaneous contraction. The spontaneous contraction reference values were obtained by studying the force response. The relative error between the spontaneous contraction frequencies computed in both ways was always lower than 0.15%. In conclusion, the use of a DIC based system allows for an accurate and noninvasive measurement of biological tissues' spontaneous contraction, in addition to the measurement of tissue strain field on any desired region of interest during electrical stimulation

    PARP-1 modulates amyloid beta peptide-induced neuronal damage.

    Get PDF
    Amyloid beta peptide (A beta) causes neurodegeneration by several mechanisms including oxidative stress, which is known to induce DNA damage with the consequent activation of poly (ADP-ribose) polymerase (PARP-1). To elucidate the role of PARP-1 in the neurodegenerative process, SH-SY5Y neuroblastoma cells were treated with A beta(25-35) fragment in the presence or absence of MC2050, a new PARP-1 inhibitor. A beta(25-35) induces an enhancement of PARP activity which is prevented by cell pre-treatment with MC2050. These data were confirmed by measuring PARP-1 activity in CHO cells transfected with amylod precursor protein and in vivo in brains specimens of TgCRND8 transgenic mice overproducing the amyloid peptide. Following A beta(25-35) exposure a significant increase in intracellular ROS was observed. These data were supported by the finding that A beta(25-35) induces DNA damage which in turn activates PARP-1. Challenge with A beta(25-35) is also able to activate NF-kB via PARP-1, as demonstrated by NF-kB impairment upon MC2050 treatment. Moreover, A beta(25-35) via PARP-1 induces a significant increase in the p53 protein level and a parallel decrease in the anti-apoptotic Bcl-2 protein. These overall data support the hypothesis of PARP-1 involvment in cellular responses induced by A beta and hence a possible rationale for the implication of PARP-1 in neurodegeneration is discussed

    Morpho-Functional Evaluation of Full-Thickness Macular Holes by the Integration of Optical Coherence Tomography Angiography and Microperimetry

    Get PDF
    (1) Objective: To use optical coherence tomography angiography (OCTA) and microperimetry (MP) to evaluate the correlation between retinal structure and function in patients with idiopathic, full-thickness macular holes (FTMHs) (2) Methods: This prospective, observational study included 11 eyes of 10 patients with FTMHs evaluated before surgery using OCTA and MP. MP sensitivity maps were superimposed and registered on slabs corresponding to superficial capillary plexus (SCP) and deep capillary plexus (DCP) on OCTA, and on the outer plexiform layer (OPL) and the Henle fiber layer (HFL) complex in en face OCT. On these maps, mean retinal sensitivity was calculated at 2 degrees and 4 degrees, all centered on the FTMH. Cystic cavity extension was assessed on the slab corresponding to the OPL + HFL complex in en face OCT and DCP in OCTA using the Image J software (Version 1.49v; National Institutes of Health, Bethesda, MD, USA); (3) Results: Absolute scotomas were observed corresponding to the FTMH. Additionally, rings of relative scotoma in the perilesional area were detected and correlated to the cystic spaces on en face OCT and OCTA. There was a significant correlation between reduced retinal sensitivity at 2 degrees and 4 degrees diameters around the FTMH and the extension of cystic areas (p < 0.01). There was a significant correlation between the extension of cystic cavities and BCVA (p < 0.01). (4) Conclusions: Morpho-functional analysis of FTMH using OCTA and MP, and the correlation between vascular abnormalities and impaired retinal sensitivity, may provide new, useful information. This integrated evaluation of FTMH may be useful to determine the function-structure correlation before and after vitreoretinal surgery, in order to gain a better understanding of the functional consequences induced by the morphological alterations, assessing outcomes in a more objective way, and potentially adding new surgical prognostic factors

    ABO blood types and major outcomes in patients with acute hypoxaemic respiratory failure: A multicenter retrospective cohort study

    Get PDF
    Introduction ABO blood type A was reported to correlate with an increased risk of acute respiratory distress syndrome (ARDS) in white patients with severe sepsis and major trauma compared with patients with other blood types. Information regarding ABO phenotypes and major outcomes in patients with ARDS is unavailable. The primary aim was to determine the relationship between ABO blood type A and intensive care unit (ICU) mortality in patients with acute hypoxemic respiratory failure (AHRF). The secondary aim was to describe the association between ABO blood type A and ICU length of stay (LOS) in this study population. Methods In a multicenter, retrospective cohort study, we collected the clinical records of patients admitted from January 2012 to December 2014 in five ICUs of Northern Italy. We included adult white patients admitted to the ICU who were diagnosed with AHRF requiring mechanical ventilation. Results The electronic records of 1732 patients with AHRF were reviewed. The proportion of patients with ABO blood type A versus other blood types was 39.9% versus 60.1%. ICU mortality (25%) and ICU LOS (median [interquartile range], 5 [2\u201312] days) were not different when stratified by ABO blood type (ICU mortality, overall p value = 0.905; ICU LOS, overall p value = 0.609). SAPSII was a positive predictor of ICU mortality (odds ration [OR], 32.80; 95% confidence interval [CI], 18.80\u201357.24; p < 0.001) and ICU LOS (\u3b2 coefficient, 0.55; 95% CI, 0.35\u20130.75; p < 0.001) at multivariate analyses, whereas ABO blood type did not predict ICU outcome when forced into the model. Conclusion ABO blood type did not correlate with ICU mortality and ICU LOS in adult patients with AHRF who were mechanically ventilated
    • …
    corecore