276 research outputs found

    SHINe: Simulator for satellite on-board high-speed networks featuring SpaceFibre and SpaceWire protocols

    Get PDF
    The continuous innovation of satellite payloads is leading to an increasing demand of data-rate for on-board satellite networks. In particular, modern optical detectors generate and need to transfer data at more than 1 Gbps, a speed that cannot be satisfied with standardized technologies such as SpaceWire. To fill this gap, the European Space Agency (ESA) is supporting the development of a new high-speed link standard, SpaceFibre. SpaceFibre provides a data-rate higher than 6.25 Gbps, together with the possibility to use multiple Virtual Channels running over the same physical link, each one configurable with flexible Quality of Service parameters. These features make a SpaceFibre network very appealing but also complex to set up in order to achieve the desired end-to-end requirements. To help this process, a Simulator for HIgh-speed Network (SHINe) based on the open-source toolkit OMNeT++ has been developed and is presented in this paper. It supports the simulation of SpaceFibre and SpaceWire protocols in order to help both the final steps of the standardization process and the system engineers in the setup and test of new networks. SHINe allows to precisely simulate common network metrics, such as latency and bandwidth usage, and it can be connected to real hardware in a Hardware-in-the-Loop configuration

    Treatment of intermetatarsal Morton's neuroma with alcohol injection under US guide: 10-month follow-up

    Get PDF
    Mortons neuroma (MN) is a frequent cause of metatarsalgia. The aim of our study was to evaluate the efficacy of neuroma alcohol-sclerosing therapy (NAST) under US guide in MN after a 10-month follow-up. Forty intermetatarsal neuromas underwent alcohol-sclerosing therapy after sonographic evaluation of their dimensions and echotexture. After subcutaneous anesthesia, a sclerosing solution composed of anesthetic (carbocaine-adrenaline 70%) and ethylic alcohol (30%) was injected inside the mass under US guidance. The procedure was repeated at intervals of 15 days until the resolution of the symptoms. A total or partial symptomatic relief was obtained in 36 cases (90%). No procedure-related complications were observed. Transitory plantar pain, due to the flogistic reaction induced by the sclerosing solution, occurred in 6 cases (15%). The 10-month follow-up revealed a 20-30% mass volume reduction and an adiposus-like change in echotexture. In the 4 cases (10%) of therapeutic failure, the preliminary sonography demonstrated a hypoechoic echotexture with a strong US beam attenuation corresponding to a highly fibrous neuroma after surgical resection. The NAST is a feasible and cost-efficient procedure with high rates of therapeutic success

    A Wire-Based Methodology to Analyse the Nanometric Resolution of an RF Cavity BPM

    Get PDF
    Resonant Cavity Beam Position Monitors (RF-BPMs) are diagnostic instruments capable of achieving beam position resolutions down to the nanometre scale. To date, their nanometric resolution capabilities have been predicted by simulation and verified through beam-based measurements with particle beams. In the frame of the PACMAN project at CERN, an innovative methodology has been developed to directly observe signal variations corresponding to nanometric displacements of the BPM cavity with respect to a conductive stretched wire. The cavity BPM of this R&D study operates at the TM110 dipole mode frequency of 15GHz. The concepts and details of the RF stretched wire BPM testbench to achieve the best resolution results are presented, along with the required control hardware and software

    The Magnetic Spin Ladder (C_{5}H_{12}N)_{2}CuBr_{4}: High Field Magnetization and Scaling Near Quantum Criticality

    Full text link
    The magnetization, M(H30M(H \leq 30 T, 0.7 K T300\leq T \leq 300 K), from single crystals and powder samples of (C5_{5}H12_{12}N)2_{2}CuBr4_{4} has been used to identify this system as an S=1/2S=1/2 Heisenberg two-leg ladder in the strong coupling limit, J=13.3J_{\perp} = 13.3 K and J=3.8J_{\parallel} = 3.8 K, with Hc1=6.6H_{c1} = 6.6 T and Hc2=14.6H_{c2} = 14.6 T. An inflection point in M(H,T=0.7M(H, T = 0.7 K) at half-saturation, Ms/2M_{s}/2, is described by an effective \emph{XXZ} chain. The data exhibit universal scaling behavior in the vicinity of Hc1H_{c1} and Hc2H_{c2}, indicating the system is near a quantum critical point.Comment: 4 pages, 4 figure

    Pulsating Heat pipe only for Space (PHOS): Results of the REXUS 18 sounding rocket campaign

    Get PDF
    Two Closed Loop Pulsating Heat Pipes (CLPHPs) are tested on board REXUS 18 sounding rocket in order to obtain data over a relatively long microgravity period (approximately 90 s). The CLPHPs are partially filled with FC-72 and have, respectively, an inner tube diameter larger (3 mm) and slightly smaller (1.6 mm) than the critical diameter evaluated in static Earth gravity conditions. On ground, the small diameter CLPHP effectively works as a Pulsating Heat Pipe (PHP): the characteristic slug and plug flow pattern forms inside the tube and the heat exchange is triggered by thermally driven self-sustained oscillations of the working fluid. On the other hand, the large diameter CLPHP works as a two- phase thermosyphon in vertical position and doesn't work in horizontal position: in this particular condition, the working fluid stratifies within the device as the surface tension force is no longer able to balance buoyancy. Then, the idea to test the CLPHPs in reduced gravity conditions: as the gravity reduces the buoyancy forces becomes less intense and it is possible to recreate the typical PHP flow pattern also for larger inner tube diameters. This allows to increase the heat transfer rate and, consequently, to decrease the overall thermal resistance. Even though it was not possible to experience low gravity conditions due to a failure in the yoyo de-spin system, the thermal response to the peculiar acceleration field (hyper-gravity) experienced on board are thoroughly described

    A multicenter, randomized controlled trial of immediate total-body CT scanning in trauma patients (REACT-2)

    Get PDF
    Contains fulltext : 110874.pdf (publisher's version ) (Open Access)BACKGROUND: Computed tomography (CT) scanning has become essential in the early diagnostic phase of trauma care because of its high diagnostic accuracy. The introduction of multi-slice CT scanners and infrastructural improvements made total-body CT scanning technically feasible and its usage is currently becoming common practice in several trauma centers. However, literature provides limited evidence whether immediate total-body CT leads to better clinical outcome then conventional radiographic imaging supplemented with selective CT scanning in trauma patients. The aim of the REACT-2 trial is to determine the value of immediate total-body CT scanning in trauma patients. METHODS/DESIGN: The REACT-2 trial is an international, multicenter randomized clinical trial. All participating trauma centers have a multi-slice CT scanner located in the trauma room or at the Emergency Department (ED). All adult, non-pregnant, severely injured trauma patients according to predefined criteria will be included. Patients in whom direct scanning will hamper necessary cardiopulmonary resuscitation or who require an immediate operation because of imminent death (both as judged by the trauma team leader) are excluded. Randomization will be computer assisted. The intervention group will receive a contrast-enhanced total-body CT scan (head to pelvis) during the primary survey. The control group will be evaluated according to local conventional trauma imaging protocols (based on ATLS guidelines) supplemented with selective CT scanning. Primary outcome will be in-hospital mortality. Secondary outcomes are differences in mortality and morbidity during the first year post trauma, several trauma work-up time intervals, radiation exposure, general health and quality of life at 6 and 12 months post trauma and cost-effectiveness. DISCUSSION: The REACT-2 trial is a multicenter randomized clinical trial that will provide evidence on the value of immediate total-body CT scanning during the primary survey of severely injured trauma patients. If immediate total-body CT scanning is found to be the best imaging strategy in severely injured trauma patients it could replace conventional imaging supplemented with CT in this specific group. TRIAL REGISTRATION: ClinicalTrials.gov: (NCT01523626)

    Design of analog front-ends for the RD53 demonstrator chip

    Get PDF
    The RD53 collaboration is developing a large scale pixel front-end chip, which will be a tool to evaluate the performance of 65 nm CMOS technology in view of its application to the readout of the innermost detector layers of ATLAS and CMS at the HL-LHC. Experimental results of the characterization of small prototypes will be discussed in the frame of the design work that is currently leading to the development of the large scale demonstrator chip RD53A to be submitted in early 2017. The paper is focused on the analog processors developed in the framework of the RD53 collaboration, including three time over threshold front-ends, designed by INFN Torino and Pavia, University of Bergamo and LBNL and a zero dead time front-end based on flash ADC designed by a joint collaboration between the Fermilab and INFN. The paper will also discuss the radiation tolerance features of the front-end channels, which were exposed to up to 800 Mrad of total ionizing dose to reproduce the system operation in the actual experiment

    Insights into SusCD-mediated glycan import by a prominent gut symbiont

    Get PDF
    In Bacteroidetes, one of the dominant phyla of the mammalian gut, active uptake of large nutrients across the outer membrane is mediated by SusCD protein complexes via a “pedal bin” transport mechanism. However, many features of SusCD function in glycan uptake remain unclear, including ligand binding, the role of the SusD lid and the size limit for substrate transport. Here we characterise the β2,6 fructo-oligosaccharide (FOS) importing SusCD from Bacteroides thetaiotaomicron (Bt1762-Bt1763) to shed light on SusCD function. Co-crystal structures reveal residues involved in glycan recognition and suggest that the large binding cavity can accommodate several substrate molecules, each up to ~2.5 kDa in size, a finding supported by native mass spectrometry and isothermal titration calorimetry. Mutational studies in vivo provide functional insights into the key structural features of the SusCD apparatus and cryo-EM of the intact dimeric SusCD complex reveals several distinct states of the transporter, directly visualising the dynamics of the pedal bin transport mechanism
    corecore