23 research outputs found

    Utility of 'dual phase' cone beam computed tomography during radioembolisation in patients with hepatocellular carcinoma : what is really changing in flow dynamics before and after 90Y delivery?

    Get PDF
    Purpose: The aims of the study were: 1) to compare two phases of dual-phase cone beam computed tomography (DPCBCT) achieved before and after Yttrium-90 (90Y) administration and to evaluate additional benefits during radioembolisation (RE) procedures; and 2) to compare DP-CBCT with pre-procedure contrast enhanced cross-sectional images in terms of tumour detection. Material and methods: Twenty-three hepatocellular carcinoma patients undergoing RE treatment were scanned with DPCBCT consisting of early arterial (EA) and late arterial (LA) phases before and after 90Y administration. The CT-like datasets were compared according to embolisation effect, enhancement patterns, lesion detectability, image quality, and artifacts by two interventional radiologists blinded to each other. The compatibility of the two radiologists was evaluated with kappa statistical analysis, and the difference between EA and LA phases was evaluated with marginal homogeneity test. Also, DP-CBCT images were compared with preprocedural cross-sectional images (CT/MRI). Results: For 23 patients 92 data were acquired. Thirteen patients showed a decrease on post-embolisation images both visually and on Hounsfield unit (HU) measurements. No statistical difference was found for tumour detection between EA and LA phases (p = 1.0). Tumour enhancement was visually superior at LA phases whereas EA phases were better for arterial mapping for selective catheterisation. DP-CBCT images were not inferior to preprocedural cross-sectional imaging findings. Conclusions: DP-CBCT is a promising tool for predicting tumour response to therapy and is not inferior to preprocedural cross-sectional imaging in terms of tumour detection. It allows better assessment during RE procedures because early phases provide good mapping for superselective catheterisation whereas late phases are better for visualisation of tumour enhancement

    Current barriers and recommendations on the diagnosis of transthyretin amyloid cardiomyopathy: a Delphi study

    Get PDF
    ObjectivesThis study has been conducted to investigate the non-invasive diagnostic journey of patients with a transthyretin amyloid cardiomyopathy (aTTR-CM) in Turkey, identify the challenges and uncertainties encountered on the path to diagnosis from the perspectives of expert physicians, and develop recommendations that can be applied in such cases.MethodsThis study employed a three-round modified Delphi method and included 10 cardiologists and five nuclear medicine specialists. Two hematologists also shared their expert opinions on the survey results related to hematological tests during a final face-to-face discussion. A consensus was reached when 80% or more of the panel members marked the “agree/strongly agree” or “disagree/strongly disagree” option.ResultsThe panelists unanimously agreed that the aTTR-CM diagnosis could be established through scintigraphy (using either 99mTc-PYP, 99mTc-DPD, or 99mTc-HMPD) in a patient with suspected cardiac amyloidosis (CA) without a further investigation if AL amyloidosis is ruled out (by sFLC, SPIE and UPIE). In addition, scintigraphy imaging performed by SPECT or SPECT-CT should reveal a myocardial uptake of Grade ≥2 with a heart-to-contralateral (H/CL) ratio of ≥1.5. The cardiology panelists recommended using cardiovascular magnetic resonance (CMR) and a detailed echocardiographic scoring as a last resort before considering an endomyocardial biopsy in patients with suspected CA whose scintigraphy results were discordant/inconclusive or negative but still carried a high clinical suspicion of aTTR-CM.ConclusionThe diagnostic approach for aTTR-CM should be customized based on the availability of diagnostic tools/methods in each expert clinic to achieve a timely and definitive diagnosis

    Nuclear Theranostics In Turkey

    No full text
    Nuclear theranostics functions as a bridge which connects targeted diagnosis to targeted therapy, just like Turkey functions as a geographical bridge which connects Asia to Europe. This unique geographical site of the country plays an important role with regard to introduction of novel scientific and technologic improvements, which originate from one continent to another, in the era of accelerated information. The first nuclear medicine practice in Turkey started in the beginning of 1950s with the first radioiodine treatment, which actually was a debut for nuclear theranostics in Turkey, years before many other countries in the world. For the time being, along with radioiodine treatment, many other theranostic applications such as I-131 MIBG treatment, Lu-177/Y-90 DOTA peptide treatment, Lu-177 PSMA treatment, Y-90 microsphere treatment, and bone palliative treatment are being performed in many centers countrywide. As science and technology improves, novel theranostic applications are eagerly awaited to be introduced in near future. This paper summarizes the story of nuclear theranostics in Turkey and aims to give an overview on the current status of theranostic applications in Turkey.Wo

    Image-based retrieval system and computer-aided diagnosis system for renal cortical scintigraphy images

    No full text
    Cortical renal (kidney) scintigraphy images are 2D images (256x256) acquired in three projection angles (posterior, right-posterior-oblique and left-posterior-oblique). These images are used by nuclear medicine specialists to examine the functional morphology of kidney parenchyma. The main visual features examined in reading the images are: size, location, shape and activity distribution (pixel intensity distribution within the boundary of each kidney). Among the above features, activity distribution (in finding scars if any) was found to have the least interobserver reproducibility. Therefore, in this study, we developed an image-based retrieval (IBR) and a computer-based diagnosis (CAD) system, focused on this feature in particular. The developed IBR and CAD algorithms start with automatic segmentation, boundary and landmark detection. Then, shape and activity distribution features are computed. Activity distribution feature is obtained using the acquired image and image set-statistics of the normal patients. Active Shape Model (ASM) technique is used for more accurate kidney segmentation. In the-training step of ASM, normal patient images are used. Retrieval performance is evaluated by calculating precision and recall. CAD performance is evaluated by specificity and sensitivity. To our knowledge, this paper is the first IBR or CAD system reported in the literature on renal cortical scintigraphy images

    The Relation Between Perfusion Pattern Of Hepatic Artery Perfusion Scintigraphy And Response To Y-90 Microsphere Therapy

    Get PDF
    Objective: Hepatic artery perfusion scintigraphy is a routine procedure for patient evaluation before Y-90 radiomicrosphere therapy and mostly used for prediction of extrahepatic leakage. Moreover, it also displays perfusion pattern of tumours, which is an important parameter on success of the therapy. The aim of this study is to assess the relation between the perfusion pattern on hepatic artery perfusion scintigraphy and radiomicrosphere therapy response., Methods: A total of 99 radiomicrosphere therapy applications were carried out in 80 patients (M/F: 55/25)., Results: Heterogeneous and diffuse perfusion patterns were observed in 47 patients and 52 patients, respectively. The patients with diffuse perfusion pattern had better therapy response both on FDG PET/CT (p= 0.04) and CT (p=0.008) when compared to those with heterogenous perfusion pattern., Conclusion: Perfusion pattern observed on hepatic artery perfusion scintigraphy may be a successful predictor of early response to radiomicrosphere therapy. , Conflict of interest:None declared.PubMe

    The position of transarterial chemoembolization with drug-eluting beads and yttrium-90 transarterial radioembolization in patients with hepatocellular carcinoma: Consensus statements from a Delphi-method expert panel in Turkey

    No full text
    PURPOSE Clinical studies conducted in different geographic regions using different methods to compare transarterial chemoembolization (TACE) and transarterial radioembolization ( TARE) have demonstrated discordant results. Meta-analyses in this field indicate comparable overall survival (OS) with TACE and TARE, while reporting a longer time to progression and a higher downstaging effect with TARE treatment. In terms of isolated procedure costs, treatment with TARE is 2 to 3 times more, and in some countries even more, expensive than TACE. However, relevant literature indicates that TARE is more advantageous compared to TACE regarding the need for repeat procedures, costs of complication management, total hospital stay and quality of life. Heterogeneity of hepatocellular carcinoma (HCC) patients as well as the shortcomings of clinical classifications, randomized clinical trials and cost-effectiveness studies make it difficult to choose between treatment alternatives in this field. As in other countries, these challenges lead to differences in treatment choice across different centers in Turkey. METHODS The present expert panel used two round modified Delphi method to investigate the resources and clinical parameters referenced while selecting patients for drug-eluting beads (DEB)-TACE and TARE treatment modalities in Turkish clinical practice. The cost-effectiveness parameters and comparisons of these treatments have also been evaluated at a prediction level. RESULTS The panelists stated that they most commonly use the BCLC staging system for the management of HCC patients in Turkey. However, they did not find any of the staging systems or treatment guidelines sufficient enough for their clinical practice in terms of covering the down-staging intent of treatments. Since living donor transplant preference is higher in Turkey than the rest of the Western countries, down-staging treatments are thought to be more prioritized in Turkey than that in other Western countries. The panelists reached a consensus that TARE may provide improved OS and reduce the number of repeat procedures compared to DEB-TACE in intermediate-stage patients with a single tumor spanning a diameter above 5 cm who experience recurrence after previous treatment with TACE and most TACE-naive patient groups in intermediate stage. CONCLUSION Based on the consensus on OS and the number of procedures, the panelists assumed that TARE would be more cost-effective than DEB-TACE in most groups of TACE-naive patients in intermediate stage and in those with a single tumor spanning a diameter above 5 cm. It was also stated that the predicted cost-effectiveness advantage of TARE could be more pronounced in patients with a tumor diameter greater than 7 cm.This study is funded by Boston Scientific.Boston Scientifi

    The Diagnostic Efficiency Of 99Mtc-Edda/Hynic-Octreotate Spect-Ct In Comparison With 111In-Pentetrotide In The Detection Of Neuroendocrine Tumours

    Get PDF
    Objective: The aim of this study was to assess the diagnostic efficiency of 99mTc-EDDA/HYNIC-Octreotate in comparison with 111Inpentetrotide scintigraphy in the detection of neuroendocrine tumors. This study also evaluates the impact of SPECT-CT hybrid imaging on somatostatin receptor scintigraphy (SRS) interpretation and clinical management of these tumors. , Methods: Fourteen patients were included in the study. All patients underwent a whole body and SPECT-CT imaging with both 99mTc- EDDA/HYNIC-octreotate and 111In-pentetrotide. Images were evaluated both visually and semiquantitatively. , Results: On patient basis, the diagnostic results of both studies were similar. The number of lesions detected by 99mTc- EDDA/HYNICOctreotate were higher than the number of lesions detected by 111In-pentetrotide however the difference was not significant (40/43( 93%), 36/43 (83%) p=0.109). Semiquantitative analysis showed higher tumor/organ count ratios for both whole-body and SPECT 99mTc- EDDA/HYNIC-Octreotate scans. , Conclusion: The results of this study suggested that, 99mTc- EDDA/HYNIC-Octreotate may be a better alternative to 111In- pentetrotide due to high image quality and lower radiation dose. SPECT/CT is a valuable tool for the assessment of neuroendocrine tumors by providing the precise anatomic localization of scintigraphic findings thus improving lesion detectability and characterization., Conflict of interest:None declared.PubMe

    Comparison Of Multichannel Intraluminal Impedance-Ph Monitoring And Reflux Scintigraphy In Pediatric Patients With Suspected Gastroesophageal Reflux

    No full text
    AIM To evaluate the agreement of multichannel intraluminal impedance-pH monitoring (MII-pHM) and gastroesophageal reflux scintigraphy (GES) for the diagnosis of gastroesophageal reflux disease. METHODS Seventy-five consecutive patients with suspected gastroesophageal reflux disease (GERD) underwent 24-h combined MII-pHM recording and one hour radionuclide scintigraphy during the course of the MII-pHM study. Catheters with 6 impedance channels and 1 pH sensor were placed transnasally. Impedance and pH data analysis were performed automatically and manually. For impedance monitoring, reflux was defined as a retrograde 50% drop in impedance, starting distally and propagating retrogradely to at least the next two more proximal measuring channels. Reflux index (RI, percentage of the entire record that esophageal pH is < 4.0) greater than 4.2% for pHM and number of refluxes more than 50 for 24 h for MII were accepted as positive test results. At scintigraphy, 240 frames of 15 seconds duration were acquired in the supine position. Gastroesophageal reflux was defined as at least one reflux episode in the esophagus. After scintigraphic evaluation, impedance-pH recordings and scintigraphic images were evaluated together and agreement between tests were evaluated with Cohen’s kappa. RESULTS Sufficient data was obtained from 60 (80%) patients (34 male, 56.7%) with a mean age of 8.7 ± 3.7 years (range: 2.5-17.3 years; median: 8.5 years). Chronic cough, nausea, regurgitation and vomiting were the most frequent symptoms. The mean time for recording of MII-pHM was 22.8 ± 2.4 h (range: 16-30 h; median: 22.7 h). At least one test was positive in 57 (95%) patients. According to diagnostic criteria, GERD was diagnosed in 34 (57.7%), 44 (73.3%), 47 (78.3%) and 51 (85%) patients by means of pHM, MII, GES and MII-pHM, respectively. The observed percentage agreements/κ values for GES and pHM, GES and MII, GES and MII-pHM, and MII and pHM are 48.3%/-0.118; 61.7%/-0.042; 73.3%/0.116 and 60%/0.147, respectively. There was no or slight agreement between GES and pHM alone, MII alone or MII-pHM. pH monitoring alone missed 17 patients compared to combined MII-pHM. The addition of MII to pH monitoring increased the diagnosis rate by 50%. CONCLUSION No or slight agreement was found among pH monitoring, MII monitoring, MII-pH monitoring and GES for the diagnosis of gastroesophageal reflux disease.PubMedWoSScopu
    corecore