721 research outputs found

    To perform a gyro test of general relativity in a satellite and develop associated control technology

    Get PDF
    Performance tests of gyroscope operations and gyroscope readout equipment are discussed. The gyroscope was tested for 400 hours at liquid helium temperatures with spin speeds up to 30 Hz. Readout by observing trapped magnetic flux in the spinning rotor with a sensitive magnetometer was accomplished. Application of the gyroscope to space probes and shuttle vehicles

    Velocity measurements by laser resonance fluorescence

    Get PDF
    The photonburst correlation method was used to detect single atoms in a buffer gas. Real time flow velocity measurements with laser induced resonance fluorescence from single or multiple atoms was demonstrated and this method was investigated as a tool for wind tunnel flow measurement. Investigations show that single atoms and their real time diffusional motion on a buffer gas can be measured by resonance fluorescence. By averaging over many atoms, flow velocities up to 88 m/s were measured in a time of 0.5 sec. It is expected that higher flow speeds can be measured and that the measurement time can be reduced by a factor of 10 or more by careful experimental design. The method is clearly not ready for incorporation in high speed wind tunnels because it is not yet known whether the stray light level will be higher or lower, and it is not known what detection efficiency can be obtained in a wind tunnel situation

    Resilience–Recovery Factors in Post-traumatic Stress Disorder Among Female and Male Vietnam Veterans: Hardiness, Postwar Social Support, and Additional Stressful Life Events

    Get PDF
    Structural equation modeling procedures were used to examine relationships among several war zone stressor dimensions, resilience-recovery factors, and post-traumatic stress disorder symptoms in a national sample of 1,632 Vietnam veterans (26% women and 74% men). A 9-factor measurement model was specified on a mixed-gender subsample of the data and then replicated on separate subsamples of female and male veterans. For both genders, the structural models supported strong mediation effects for the intrapersonal resource characteristic of hardiness, postwar structural and functional social support, and additional negative life events in the postwar period. Support for moderator effects or buffering in terms of interactions between war zone stressor level and resiliencerecovery factors was minimal

    To perform a gyro test of general relativity in a satellite and develop associated control technology

    Get PDF
    A satellite configuration having two gyroscopes with axes parallel to the boresight of a telescope and two at right angles to the telescope and approximately parallel and perpendicular to the earth's axis is proposed for measuring geodetic precessions due to the earth's motion about the sun, higher order geodetic terms calculated from the earth's quadrapole mass moment (0.010 arc-sec/year in a 400 nautical mile polar orbit), and deflection by the sun of the starlight signal for the reference telescope. Data from the experiment also contain large periodic signals due to the annual and orbital aberrations of starlight which are useful in providing a built in reference signal of known amplitude for scaling the relativity signals, and should yield a singularly precise measurement of the parallax of the reference star. The development of the gyroscope and its readout system are discussed, as well as signal integration, drag-free control, and attitude control

    Measurement of the Hyperfine Structure and Isotope Shifts of the 3s23p2 3P2 to 3s3p3 3Do3 Transition in Silicon

    Full text link
    The hyperfine structure and isotope shifts of the 3s23p2 3P2 to 3s3p3 3Do3 transition in silicon have been measured. The transition at 221.7 nm was studied by laser induced fluorescence in an atomic Si beam. For 29Si, the hyperfine A constant for the 3s23p2 3P2 level was determined to be -160.1+-1.3 MHz (1 sigma error), and the A constant for the 3s3p3 3Do3 level is -532.9+-0.6 MHz. This is the first time that these constants were measured. The isotope shifts (relative to the abundant isotope 28Si) of the transition were determined to be 1753.3+-1.1 MHz for 29Si and 3359.9+-0.6 MHz for 30Si. This is an improvement by about two orders of magnitude over a previous measurement. From these results we are able to predict the hyperfine structure and isotope shift of the radioactive 31Si atom, which is of interest in building a scalable quantum computer

    Perform a gyro test of general relativity in a satellite and develop associated control technology

    Get PDF
    The progress accomplished in the Stanford Gyro Relativity program during the period November 1974 to October 1975 was described. Gyro developments were continued in the main laboratory dewar, concentrating on the operation of a three axis gyro readout and on improvements to the methods of canceling trapped fields in the rotor; these efforts culminated in the first successful observation of the London moment in the spinning gyro rotor in March 1975. Following a review meeting at that time, a new goal was formulated for the next 12 to 18 months, namely to operate a gyroscope in the new ultra-low field facility with readout resolution approaching 1 arc-second. The following other tasks were also completed: (1) sputtering work, (2) magnetometry, (3) construction and installation of the North Star simulator, (4) analysis of torques on the gyro, especially in inclined orbits, (5) equivalence principle accelerometer, and (6) analysis of a twin-satellite test of relativity

    Determination of the Oswestry Disability Index score equivalent to a "satisfactory symptom state" in patients undergoing surgery for degenerative disorders of the lumbar spine-a Spine Tango registry-based study.

    Get PDF
    BACKGROUND CONTEXT The achievement of a given change score on a valid outcome instrument is commonly used to indicate whether a clinically relevant change has occurred after spine surgery. However, the achievement of such a change score can be dependent on baseline values and does not necessarily indicate whether the patient is satisfied with the current state. The achievement of an absolute score equivalent to a patient acceptable symptom state (PASS) may be a more stringent measure to indicate treatment success. PURPOSE This study aimed to estimate the score on the Oswestry Disability Index (ODI, version 2.1a; 0-100) corresponding to a PASS in patients who had undergone surgery for degenerative disorders of the lumbar spine. STUDY DESIGN/SETTING This is a cross-sectional study of diagnostic accuracy using follow-up data from an international spine surgery registry. PATIENT SAMPLE The sample includes 1,288 patients with degenerative lumbar spine disorders who had undergone elective spine surgery, registered in the EUROSPINE Spine Tango Spine Surgery Registry. OUTCOME MEASURES The main outcome measure was the ODI (version 2.1a). METHODS Surgical data and data from the ODI and Core Outcome Measures Index (COMI) were included to determine the ODI threshold equivalent to PASS at 1 year (±1.5 months; n=780) and 2 years (±2 months; n=508) postoperatively. The symptom-specific well-being item of the COMI was used as the external criterion in the receiver operating characteristic (ROC) analysis to determine the ODI threshold equivalent to PASS. Separate sensitivity analyses were performed based on the different definitions of an "acceptable state" and for subgroups of patients. JF is a copyright holder of the ODI. RESULTS The ODI threshold for PASS was 22, irrespective of the time of follow-up (area under the curve [AUC]: 0.89 [sensitivity {Se}: 78.3%, specificity {Sp}: 82.1%] and AUC: 0.91 [Se: 80.7%, Sp: 85.6] for the 1- and 2-year follow-ups, respectively). Sensitivity analyses showed that the absolute ODI-22 threshold for the two follow-up time-points were robust. A stricter definition of PASS resulted in lower ODI thresholds, varying from 16 (AUC=0.89; Se: 80.2%, Sp: 82.0%) to 18 (AUC=0.90; Se: 82.4%, Sp: 80.4%) depending on the time of follow-up. CONCLUSIONS An ODI score ≤22 indicates the achievement of an acceptable symptom state and can hence be used as a criterion of treatment success alongside the commonly used change score measures. At the individual level, the threshold could be used to indicate whether or not a patient with a lumbar spine disorder is a "responder" after elective surgery
    corecore