341 research outputs found

    Organic electrochemistry: Synthesis and functionalization of β-lactams in the twenty-first century

    Get PDF
    Organic electrochemistry is a technique that allows for the heterogeneous redox reactions avoiding both the use of stoichiometric amounts of redox reagents and the resulting formation of stoichiometric by-pro- ducts. In fact, the redox reagent in these reactions is the electron, which is naturally eco-friendly and pro- duces no side compounds. It is therefore quite obvious that electrochemistry can be classified as a “green” tech- nology. The use of this methodology in the synthesis of β-lactams is not a novelty, but the growing interest in this class of biologically active compounds, due to the dis- covery of new fields of application (after a moment of decrease in interest due to antibiotic resistance) has been a stimulus for the search for more efficient electro- chemical ways to synthesize and transform β-lactams. Thus, this review deals with the twenty-first-century applications of electroorganic technique to the chemistry of β-lactams, by analyzing first the syntheses classified by the type of reactions (cyclization, cycloaddition, etc.) and then by manipulating the β-lactam structure, using it as a synthon. Lastly, the importance of this technique is demonstrated by a study of a pilot plant scale reduction of a cephalosporanic acid derivative to a commercially important antibiotic

    Release of Palladium from Biomechanical Prostheses in Body Fluids Can Induce or Support PD-Specific IFNγ T Cell Responses and the Clinical Setting of a Palladium Hypersensitivity:

    Get PDF
    The increased use of Palladium (Pd) for biomedical applications, which has more than doubled in the last ten years, appears to be associated with an increased frequency of adverse reactions to Pd. The aim of this study is to investigate the relationship between the implant of a biomechanical apparatus containing Pd and the setting of a hypersensitivity to Pd by determining the levels of the metal released in biological fluids, assessing the effects of Pd on peripheral blood mononuclear cell (PBMC) cytokine production and exploring the clinical setting of skin sensitization. Of a total of 3,093 subjects examined in 2006, sensitization to Pd alone or in association with nickel (Ni) was observed in 1.6% and 13.03% of the individuals, respectively. Of these, a group of six subjects positive to Pd and negative to Ni at patch testing were selected on the basis of the oral clinical symptoms in order to measure both the levels of Pd in biological fluids and the degradation of the dental prostheses. Specific Pd measurements were carried out on salivary fluid, urine and serum samples by High Resolution Inductively Coupled Plasma-Mass Spectrometry. In addition, the degradation of the dental prostheses was assessed by both a "leaching test" and an analysis of the micro morphology of orthodontic prostheses. The induction of IFN-γ production by Pd was assessed in PBMC by the ELISpot assay. Skin sensitization to Pd was evaluated by patch testing and clinical examination. Ten healthy subjects were comparatively tested as controls. We found a specific induction of an IFN-γ response by Pd in PBMC collected from all the subjects positive to Pd at patch testing. On the contrary, control subjects did not show any response to Pd as assessed by IFN-γ ELISpot assay or by skin testing. Remarkably, the levels of Pd in all biological samples (saliva, sera, urine) were significantly higher in Pd-sensitized patients than in those collected from controls, reaching the highest concentrations in the urine. The leaching studies gave additional evidence that the dental appliances can release measurable levels of Pd in saliva. Oral clinical symptoms in patients with Pd dental prostheses were associated with measurable levels of Pd in the biological fluids, the induction of Pd-specific IFN-γ responses in PBMC and the clinical evidence of skin sensitization to Pd. These data suggest that dental appliances may represent an active source of Pd in the body, and this, in turn, can favour the clinical setting of a hypersensitivity to this metal

    Cohort study of prevalence and phenomenology of tremor in dementia with Lewy bodies

    Get PDF
    To study prevalence, specific patterns and response to treatment of tremor in dementia with Lewy bodies (DLB), in comparison with other tremulous disorders prevalence, qualitative and quantitative features of tremor were studied in an incident cohort of 67 dopaminergic treatment naive DLB, 111 Parkinson’s Disease (PD) and 34 Essential Tremor (ET) patients. Tremulous DLB patients (tDLB) were compared with tremulous PD (tPD) and ET patients and followed for 2 years. Double blind placebo-controlled acute drug challenge with l-Dopa and alcohol was performed in all ET, 24 tDLB and 27 tPD. Effects of dopaminergic chronic treatment in all tDLB and tPD patients and primidone in 8 tDLB were also assessed. Tremor occurred in 44.76 % of DLB patients. The tDLB patients presented a complex pattern of mixed tremors, characterized by rest and postural/action tremor, including walking tremor and standing overflow in 50 % tDLB. Standing tremor with overflow was characteristic of tDLB (p \u3c 0.001). Head tremor was more frequent in tDLB than tPD and ET (p = 0.001). The tDLB tremors were reduced by acute and chronic dopaminergic treatments (p \u3c 0.01) but not by alcohol or primidone. Tremor occurs commonly in DLB patients with a complex mixed tremor pattern which shows a significant response to acute and chronic dopaminergic treatments. Recognizing that there is a clinical category of tremulous DLB may help the differential diagnosis of tremors. Electronic supplementary material The online version of this article (doi:10.1007/s00415-013-6853-y) contains supplementary material, which is available to authorized users

    Neutron irradiation test on ATLAS MDT chambers

    Get PDF
    Abstract The Monitored Drift Tubes (MDT) chambers of the ATLAS muon spectrometer are crucial for the identification of high-momentum final-state muons, which represent very promising and robust signatures of physics at the LHC. They will operate in a high rate and high background environment and therefore their performances should not significantly degrade for the whole ATLAS data taking. The maximum expected total flux, mainly consisting of neutrons and photons in the MeV range, is of the order of 5 kHz/cm 2 for the barrel MDTs, while at SLHC, with machine working at higher luminosity, fluxes can be 10 times higher. To test detector robustness, a MDT test chamber was exposed to intensive neutron irradiation at the TAPIRO ENEA-Casaccia Research Center facility

    Growth, electronic and electrical characterization of Ge-Rich Ge-Sb-Te alloy

    Get PDF
    In this study, we deposit a Ge-rich Ge-Sb-Te alloy by physical vapor deposition (PVD) in the amorphous phase on silicon substrates. We study in-situ, by X-ray and ultraviolet photoemission spectroscopies (XPS and UPS), the electronic properties and carefully ascertain the alloy composition to be GST 29 20 28. Subsequently, Raman spectroscopy is employed to corroborate the results from the photoemission study. X-ray diffraction is used upon annealing to study the crystallization of such an alloy and identify the effects of phase separation and segregation of crystalline Ge with the formation of grains along the [111] direction, as expected for such Ge-rich Ge-Sb-Te alloys. In addition, we report on the electrical characterization of single memory cells containing the Ge-rich Ge-Sb-Te alloy, including I-V characteristic curves, programming curves, and SET and RESET operation performance, as well as upon annealing temperature. A fair alignment of the electrical parameters with the current state-of-the-art of conventional (GeTe)n-(Sb2Te3)m alloys, deposited by PVD, is found, but with enhanced thermal stability, which allows for data retention up to 230 °C

    XIPE: the X-ray Imaging Polarimetry Explorer

    Full text link
    X-ray polarimetry, sometimes alone, and sometimes coupled to spectral and temporal variability measurements and to imaging, allows a wealth of physical phenomena in astrophysics to be studied. X-ray polarimetry investigates the acceleration process, for example, including those typical of magnetic reconnection in solar flares, but also emission in the strong magnetic fields of neutron stars and white dwarfs. It detects scattering in asymmetric structures such as accretion disks and columns, and in the so-called molecular torus and ionization cones. In addition, it allows fundamental physics in regimes of gravity and of magnetic field intensity not accessible to experiments on the Earth to be probed. Finally, models that describe fundamental interactions (e.g. quantum gravity and the extension of the Standard Model) can be tested. We describe in this paper the X-ray Imaging Polarimetry Explorer (XIPE), proposed in June 2012 to the first ESA call for a small mission with a launch in 2017 but not selected. XIPE is composed of two out of the three existing JET-X telescopes with two Gas Pixel Detectors (GPD) filled with a He-DME mixture at their focus and two additional GPDs filled with pressurized Ar-DME facing the sun. The Minimum Detectable Polarization is 14 % at 1 mCrab in 10E5 s (2-10 keV) and 0.6 % for an X10 class flare. The Half Energy Width, measured at PANTER X-ray test facility (MPE, Germany) with JET-X optics is 24 arcsec. XIPE takes advantage of a low-earth equatorial orbit with Malindi as down-link station and of a Mission Operation Center (MOC) at INPE (Brazil).Comment: 49 pages, 14 figures, 6 tables. Paper published in Experimental Astronomy http://link.springer.com/journal/1068

    Elotuzumab plus pomalidomide and dexamethasone in relapsed/refractory multiple myeloma: a multicenter, retrospective real-world experience with 200 cases outside of controlled clinical trials

    Get PDF
    In the ELOQUENT-3 trial, the combination of elotuzumab, pomalidomide and dexamethasone (EloPd) proved a superior clinical benefit over Pd with a manageable toxicity profile, leading to its approval in relapsed/refractory multiple myeloma (RRMM), who had received at least two prior therapies, including lenalidomide and a proteasome inhibitor (PI). We report here a real-world experience of 200 RRMMs treated with EloPd in 35 Italian centers outside of clinical trials. In our dataset, the median number of prior lines of therapy was 2, with 51% of cases undergoing autologous stem cell transplant (ASCT) and 73% exposed to daratumumab. After a median follow-up of 9 months, 126 patients stopped EloPd, most of them (88.9%) because of disease progression. The overall response rate (ORR) was 55.4%, in line with the pivotal trial results. Regarding adverse events, our cohort experienced a toxicity profile similar to the ELOQUENT-3 trial, with no significant differences between younger (<70 years) and older patients. The median progression-free survival (PFS) was 7 months, shorter than that observed in the ELOQUENT-3, probably due to the different clinical characteristics of the two cohorts. Interestingly, the ISS stage III (HR:2.55) was associated with worse PFS. Finally, our series's median overall survival (OS) was shorter than that observed in the ELOQUENT-3 trial (17.5 versus 29.8 months). In conclusion, our real-world study confirms EloPd as a safe and possible therapeutic choice for RRMM who received at least two prior therapies, including lenalidomide and a PI

    LIME -- a gas TPC prototype for directional Dark Matter search for the CYGNO experiment

    Full text link
    The CYGNO experiment aims at the development of a large gaseous TPC with GEM-based amplification and an optical readout by means of PMTs and scientific CMOS cameras for 3D tracking down to O(keV) energies, for the directional detection of rare events such as low mass Dark Matter and solar neutrino interactions. The largest prototype built so far towards the realisation of the CYGNO experiment demonstrator is the 50 L active volume LIME, with 4 PMTs and a single sCMOS imaging a 33×\times33 cm\textsuperscript{2} area for 50 cm drift, that has been installed in underground Laboratori Nazionali del Gran Sasso in February 2022. We will illustrate LIME performances as evaluated overground in Laboratori Nazionali di Frascati by means of radioactive X-ray sources, and in particular the detector stability, energy response and energy resolution. We will discuss the MC simulation developed to reproduce the detector response and show the comparison with actual data. We will furthermore examine the background simulation worked out for LIME underground data taking and illustrate the foreseen expected measurement and results in terms of natural and materials intrinsic radioactivity characterisation and measurement of the LNGS underground natural neutron flux. The results that will be obtained by underground LIME installation will be paramount in the optimisation of the CYGNO demonstrator, since this is foreseen to be composed by multiple modules with the same LIME dimensions and characteristics

    Technical Design Report - TDR CYGNO-04/INITIUM

    Get PDF
    The aim of this Technical Design Report is to illustrate the technological choices foreseen to be implemented in the construction of the CYGNO-04 demonstrator, motivate them against the experiment physics goals of CYGNO-30 and demonstrate the financial sustainability of the project. CYGNO-04 represents PHASE 1 of the long term CYGNO roadmap, towards the development of large high precision tracking gaseous Time Projection Chamber (TPC) for directional Dark Matter searches and solar neutrino spectroscopy. The CYGNO project1 peculiarities reside in the optical readout of the light produced during the amplification of the primary ionization electrons in a stack of triple Gas Electron Multipliers (GEMs), thanks to the nice scintillation properties of the chosen He:CF4 gas mixture. To this aim, CYGNO is exploiting the fast progress in commercial scientific Active Pixel Sensors (APS) development for highly performing sCMOS cameras, whose high granularity and sensitivity allow to significantly boost tracking, improve particle identification and lower the energy threshold. The X-Y track project obtained from the reconstruction of the sCMOS images is combined with a PMT measurement to obtain a full 3D track reconstruction. In addition, several synergic R&Ds based on the CYGNO experimental approach are under development in the CYGNO collaboration (see Sec 2) to further enhance the light yield by means of electro luminescence after the amplification stage, to improve the tracking performances by exploiting negative ion drift operation within the INITIUM ERC Consolidator Grant, and to boost the sensitivity to O(GeV) Dark Matter masses by employing hydrogen rich target towards the development of PHASE 2 (see Sec. 1.2). While still under optimization and subject to possible significant improvements, the CYGNO experimental approach performances and capabilities demonstrated so far with prototypes allow to foresee the development of an O(30) m3 experiment by 2026 for a cost of O(10) MEUROs. A CYGNO-30 experiment would be able to give a significant contribution to the search and study of Dark Matter with masses below 10 GeV/c2 for both SI and SD coupling. In case of a Dark Matter observation claim by other experiments, the information provided by a directional detector such as CYGNO would be fundamental to positively confirm the galactic origin of the allegedly detected Dark Matter signal. CYGNO-30 could furthermore provide the first directional measurement of solar neutrinos from the pp chain, possibly extending to lower energies the Borexino measurement2. In order to reach this goal, the CYGNO project is proceeding through a staged approach. The PHASE 0 50 L detector (LIME, recently installed underground LNGS) will validate the full performances of the optical readout via APS commercial cameras and PMTs and the Montecarlo simulation of the expected backgrounds. The full CYGNO-04 demonstrator will be realized with all the technological and material choices foreseen for CYGNO-30, to demonstrate the scalability of the experimental approach and the potentialities of the large PHASE 2 detector to reach the expected physics goals. The first PHASE 1 design anticipated a 1 m3 active volume detector with two back-to-back TPCs with a central cathode and 500 mm drift length. Each 1 m2 readout area would have been composed by 9 + 9 readout modules having the LIME PHASE 0 dimensions and layout. Time (end of INITIUM project by March 2025) and current space availability at underground LNGS (only Hall F) forced the rescaling of the PHASE 1 active volume and design to a 0.4 m3, hence CYGNO-04. CYGNO-04 will keep the back-to-back double TPC layout with 500 mm drift length each, but with an 800 x 500 mm2 readout area covered by a 2 + 2 modules based on LIME design. The reduction of the detector volume has no impact on the technological objectives of PHASE 1, since the modular design with central cathode, detector materials and shieldings and auxiliary systems are independent of the total volume. The physics reach (which is a byproduct of PHASE 1 and NOT an explicit goal) will be only very partially reduced (less than a factor 2 overall) since a smaller detector volume implies also a reduced background from internal materials radioactivity. In addition, the cost reduction of CYGNO-04 of about 1⁄3 with respect to CYGNO-1 illustrated in the CDR effectively makes the overall project more financially sustainable (see CBS in the last section). In summary this document will explain: the physical motivation of the CYGNO project and the technical motivations of the downscale of the PHASE 1 to CYGNO-04, 400 liters of active volume, with respect to the demonstrator presented in the CDR; the results of R&D and the Montecarlo expectations for PHASE 0; the technical choices, procedures and the executive drawings of CYGNO-04 in the Hall F of the LNGS; safety evaluations and the interference/request to the LNGS services; Project management, WBS/WBC, WP, GANTT, ec
    corecore