8,269 research outputs found

    Simbol-X Background Minimization: Mirror Spacecraft Passive Shielding Trade-Off Study

    Full text link
    The present work shows a quantitative trade-off analysis of the Simbol-X Mirror Spacecraft (MSC) passive shielding, in the phase space of the various parameters: mass budget, dimension, geometry, and composition. A simplified physical (and geometrical) model of the sky screen, implemented by means of a GEANT4 simulation, has been developed to perform a performance-driven mass optimization and evaluate the residual background level on Simbol-X focal plane.Comment: 3 pages, 6 figures, to appear in the proceedings of the second Simbol-X International Symposium "Simbol-X - Focusing on the Hard X-ray Universe", AIP Conf. Proc. Series, P. Ferrando and J. Rodriguez ed

    Estimation of intake and digestibility of kleingrass from in situ parameters measured in sheep

    Get PDF
    The voluntary intake and digestibility of kleingrass (Panicum coloratum cv. Verde) were measured in seven periods, comprising one full year. The forage was offered twice a day ad Iibitum to .seven rams, frtted with faces collection bags; each experimental period was composed of 8 days for adaptation and 8 days for collection of data. The dry matter (DM) Intake (DMI) varied from 36.1 to 64.9 glkg MO.75, the digestible dry-matter Intake (DDMI), from 17.4 to 41.9 glkg MO.75 and the in vivo dry matter apparent digestibility (DMD), from 0.471 to 0.667. Daily samples of offered forage were taken and pooled subsamples from each of the seven periods were incubated in nylon bags in the rumen of three Hereford steers. The data were fitted to the exponential equation: p= a + b (1-e~) to estimate p (the proportionate loss of DM at time t of incubation); effective degradability (ED) and lag time (L) were also estimated. The parameters obtained in situ were related to the in vivo results by simple and multiple regression. The correlation coefficients of the rate of degradation {9 and ED with DMI, DDMI and DMD were, respectively, 0.96 and 0.97; 0.97 and 0.96; 0.86 and 0.88. By including, Q, Q and k into a multiple regression analysis, the coefficients of determination (R2) were: DMI: 0.99; DDMI: 0.99 and DMD: 0.91. Within the conditions of this study, the parameters obtained in situ were reasonable estimators of voluntary intake and digestibility.Resúmenes de Trabajos presentados en otras publicaciones (por docentes de la UNLPam.) Publicado en Animal Science, 67: 535-540, 1998

    Augmented reality for dental implantology: a pilot clinical report of two cases

    Get PDF
    Background: Despite the limited number of articles dedicated to its use, augmented reality (AR) is an emerging technology that has shown to have increasing applications in multiple different medical sectors. These include, but are not limited to, the Maxillo-facial and Dentistry disciplines of medicine. In these medical specialties, the focus of AR technology is to achieve a more visible surgical field during an operation. Currently, this goal is brought about by an accurate display of either static or dynamic diagnostic images via the use of a visor or specific glasses. The objective of this study is to evaluate the feasibility of using a virtual display for dynamic navigation via AR. The secondary outcome is to evaluate if the use of this technology could affect the accuracy of dynamic navigation. Case presentation: Two patients, both needing implant rehabilitation in the upper premolar area, were treated with flapless surgery. Prior to the procedure itself, the position of the implant was virtually planned and placed for each of the patients using their previous scans. This placement preparation contributed to a dynamic navigation system that was displayed on AR glasses. This, in turn, allowed for the use of a computer-aided/image-guided procedure to occur. Dedicated software for surface superimposition was then used to match the planned position of the implant and the real one obtained from the postoperative scan. Accuracies, using this procedure were evaluated by way of measuring the deviation between real and planned positions of the implants. For both surgeries it was possible to proceed using the AR technology as planned. The deviations for the first implant were 0.53\u2009mm at the entry point and 0.50\u2009mm at the apical point and for the second implant were 0.46\u2009mm at the entry point and 0.48\u2009mm at the apical point. The angular deviations were respectively 3.05\ub0 and 2.19\ub0. Conclusions: From the results of this pilot study, it seems that AR can be useful in dental implantology for displaying dynamic navigation systems. While this technology did not seem to noticeably affect the accuracy of the procedure, specific software applications should further optimize the results

    Slow and fast micro-field components in warm and dense hydrogen plasmas

    Full text link
    The aim of this work is the investigation of the statistical properties of local electric fields in an ion-electron two component plasmas for coupled conditions. The stochastic fields at a charged or at a neutral point in plasmas involve both slow and fast fluctuation characteristics. The statistical study of these local fields based on a direct time average is done for the first time. For warm and dense plasma conditions, typically Ne1018cm3N_{e}\approx 10^{18}cm^{-3}, % T_{e}\approx 1eV, well controlled molecular dynamics (MD) simulations of neutral hydrogen, protons and electrons have been carried out. Relying on these \textit{ab initio} MD calculations this work focuses on an analysis of the concepts of statistically independent slow and fast local field components, based on the consideration of a time averaged electric field. Large differences are found between the results of these MD simulations and corresponding standard results based on static screened fields. The effects discussed are of importance for physical phenomena connected with stochastic electric field fluctuations, e.g., for spectral line broadening in dense plasmas.Comment: 4 pages, 4 figures, submitted to Phys. Rev. Let

    reliable and inexpensive solar irradiance measurement system design

    Get PDF
    Abstract In this work, we present an innovative low cost sensor and algorithm for the monitoring and measurement of solar irradiance. This parameter is usually estimated using pyranometers, often based on thermopile. They are quite expensive, also because need additional hardware for data acquisition and manipulation as well as non-negligible installation costs. The system architecture and novel algorithm here proposed employ small PhotoVoltaic (PV) cells and a digital sensor interface. Moreover, the logic section permits to tilt the sensor allowing to track the sun with improved accuracy

    Resting state alpha oscillatory activity is a valid and reliable marker of schizotypy

    Get PDF
    Schizophrenia is among the most debilitating neuropsychiatric disorders. However, clear neurophysiological markers that would identify at-risk individuals represent still an unknown. The aim of this study was to investigate possible alterations in the resting alpha oscillatory activity in normal population high on schizotypy trait, a physiological condition known to be severely altered in patients with schizophrenia. Direct comparison of resting-state EEG oscillatory activity between Low and High Schizotypy Group (LSG and HSG) has revealed a clear right hemisphere alteration in alpha activity of the HSG. Specifically, HSG shows a significant slowing down of right hemisphere posterior alpha frequency and an altered distribution of its amplitude, with a tendency towards a reduction in the right hemisphere in comparison to LSG. Furthermore, altered and reduced connectivity in the right fronto-parietal network within the alpha range was found in the HSG. Crucially, a trained pattern classifier based on these indices of alpha activity was able to successfully differentiate HSG from LSG on tested participants further confirming the specific importance of right hemispheric alpha activity and intrahemispheric functional connectivity. By combining alpha activity and connectivity measures with a machine learning predictive model optimized in a nested stratified cross-validation loop, current research offers a promising clinical tool able to identify individuals at-risk of developing psychosis (i.e., high schizotypy individuals)

    Mixed cryoglobulinemia

    Get PDF
    Mixed cryoglobulinemia (MC), type II and type III, refers to the presence of circulating cryoprecipitable immune complexes in the serum and manifests clinically by a classical triad of purpura, weakness and arthralgias. It is considered to be a rare disorder, but its true prevalence remains unknown. The disease is more common in Southern Europe than in Northern Europe or Northern America. The prevalence of 'essential' MC is reported as approximately 1:100,000 (with a female-to-male ratio 3:1), but this term is now used to refer to a minority of MC patients only. MC is characterized by variable organ involvement including skin lesions (orthostatic purpura, ulcers), chronic hepatitis, membranoproliferative glomerulonephritis, peripheral neuropathy, diffuse vasculitis, and, less frequently, interstitial lung involvement and endocrine disorders. Some patients may develop lymphatic and hepatic malignancies, usually as a late complication. MC may be associated with numerous infectious or immunological diseases. When isolated, MC may represent a distinct disease, the so-called 'essential' MC. The etiopathogenesis of MC is not completely understood. Hepatitis C virus (HCV) infection is suggested to play a causative role, with the contribution of genetic and/or environmental factors. Moreover, MC may be associated with other infectious agents or immunological disorders, such as human immunodeficiency virus (HIV) infection or primary Sjögren's syndrome. Diagnosis is based on clinical and laboratory findings. Circulating mixed cryoglobulins, low C4 levels and orthostatic skin purpura are the hallmarks of the disease. Leukocytoclastic vasculitis involving medium- and, more often, small-sized blood vessels is the typical pathological finding, easily detectable by means of skin biopsy of recent vasculitic lesions. Differential diagnoses include a wide range of systemic, infectious and neoplastic disorders, mainly autoimmune hepatitis, Sjögren's syndrome, polyarthritis, and B-cell lymphomas. The first-line treatment of MC should focus on eradication of HCV by combined interferon-ribavirin treatment. Pathogenetic treatments (immunosuppressors, corticosteroids, and/or plasmapheresis) should be tailored to each patient according to the progression and severity of the clinical manifestations. Long-term monitoring is recommended in all MC patients to assure timely diagnosis and treatment of the life-threatening complications. The overall prognosis is poorer in patients with renal disease, liver failure, lymphoproliferative disease and malignancies

    SiPM and front-end electronics development for Cherenkov light detection

    Full text link
    The Italian Institute of Nuclear Physics (INFN) is involved in the development of a demonstrator for a SiPM-based camera for the Cherenkov Telescope Array (CTA) experiment, with a pixel size of 6×\times6 mm2^2. The camera houses about two thousands electronics channels and is both light and compact. In this framework, a R&D program for the development of SiPMs suitable for Cherenkov light detection (so called NUV SiPMs) is ongoing. Different photosensors have been produced at Fondazione Bruno Kessler (FBK), with different micro-cell dimensions and fill factors, in different geometrical arrangements. At the same time, INFN is developing front-end electronics based on the waveform sampling technique optimized for the new NUV SiPM. Measurements on 1×\times1 mm2^2, 3×\times3 mm2^2, and 6×\times6 mm2^2 NUV SiPMs coupled to the front-end electronics are presentedComment: In Proceedings of the 34th International Cosmic Ray Conference (ICRC2015), The Hague, The Netherlands. All CTA contributions at arXiv:1508.0589

    Dry matter production and nutritive value of forage of Digitaria eriantha cv. Irene in two locations oft be central semi-arid region of Argentina

    Get PDF
    The aim of this experiment was to compare dry matter (DM) production rates and nutritive value of a warm-season grass, Digitaria erisntha ev. Irene, in two locations of Central Argentina, Santa Rosa (SR) and Villa Mercedes (VM). The plants were established in two identical groups of plots, within a randomized block design DM rates were calculated from serial, out of phase clippings, and in vitro dry matter digestibility (IVDMD) and crude protein (CP) content analyzed on subsamples. The study lasted for three consecutive growing seasons. Results showed that DM production rates were generally higher (P<0.05) in SR than in VM, but IVDMD and CP content showed no clear trends between both locations. DM production tended to lower from year 1 to 3, related to processes of N depletion from soils (VM) and diminishing rainfall (SR). It is concluded that D. eriantha is a very promising warm-season grass to Central Argentina. Data of nutritive value obtained in one location can be used in others, but results of DM production rates should be taken under the conditions where they will be used.Resúmenes de Trabajos presentados en otras publicaciones (por docentes de la UNLPam.)  Publicado en Proceedings of the XVIII international grassland congress. Forage and Management, Session 22: 101-102, 1997
    corecore