396 research outputs found

    Restoration of the Broken D2-Symmetry in the Mean Field Description of Rotating Nuclei

    Get PDF
    Signature effects observed in rotational bands are a consequence of an inherent D2-symmetry. This symmetry is naturally broken by the mean field cranking approximation when a tilted (non-principal) axis orientation of the nuclear spin becomes stable. The possible tunneling forth and back between the two symmetry-related minima in the double-humped potential-energy surface appears as a typical bifurcation of the rotational band. We describe this many-body process in which all nucleons participate by diagonalizing the nuclear Hamiltonian within a selected set of tilted and non-tilted cranking quasiparticle states. This microscopic approach is able to restore the broken D2 symmetry and reproduce the quantum fluctuations between symmetry- related HFB states which emerge as splitting of the band energies and in parallel staggering in intraband M1 transitions.Comment: 9 pages, 4 figure

    Vies moyennes de niveaux de 53Mn excités par la réaction 50Cr (α, pγ)53Mn

    No full text
    Les propriétés électromagnétiques du noyau 53Mn sont étudiées à l'aide de la réaction 50Cr(α, pγ)53Mn à Eα = 14,5 MeV. Les rayonnements γ sont détectés en coïncidence avec les groupes de protons observés à l'aide d'un détecteur annulaire placé à 180° dans l'axe du faisceau. Des rapports d'embranchement de transitions γ sont donnés. La méthode d'atténuation de l'effet Doppler a été utilisée pour déduire les vies moyennes : niveau de 3,42 MeV, τ = 1,0 +0,6-0,4 ps ; niveau de 3,44 MeV, τ = 0,13 +0,05-0,04ps ; niveau de 4,15 MeV, τ = 0,07 ± 0,02 ps. Pour les niveaux à Ex < 3 MeV nos valeurs de τ sont en accord avec des résultats obtenus ailleurs. Pour le niveau de 3,44 MeV nous déduisons Jπ = 15/2- sans ambiguïté. Certaines probabilités de transitions B(M1) et B(E2) sont déterminées et comparées aux prédictions des modèles récents

    Elevated Lipid Oxidation Is Associated with Exceeding Gestational Weight Gain Recommendations and Increased Neonatal Anthropometrics: A Cross-Sectional Analysis

    Get PDF
    BACKGROUND: Deviations from gestational weight gain (GWG) recommendations are associated with unfavorable maternal and neonatal outcomes. There is a need to understand how maternal substrate metabolism, independent of weight status, may contribute to GWG and neonatal outcomes. The purpose of this study was to explore the potential link between maternal lipid oxidation rate, GWG, and neonatal anthropometric outcomes. METHODS: Women (N = 32) with a lean pre-pregnancy BMI were recruited during late pregnancy and substrate metabolism was assessed using indirect calorimetry, before and after consumption of a high-fat meal. GWG was categorized as follows: inadequate, adequate, or excess. Shortly after delivery (within 48 h), neonatal anthropometrics were obtained. RESULTS: Using ANOVA, we found that fasting maternal lipid oxidation rate (grams/minute) was higher (p = 0.003) among women with excess GWG (0.1019 ± 0.0416) compared to women without excess GWG (inadequate = 0.0586 ± 0.0273, adequate = 0.0569 ± 0.0238). Findings were similar when lipid oxidation was assessed post-meal and also when expressed relative to kilograms of fat free mass. Absolute GWG was positively correlated to absolute lipid oxidation expressed in grams/minute at baseline (r = 0.507, p = 0.003), 2 h post-meal (r = 0.531, p = 0.002), and 4 h post-meal (r = 0.546, p = 0.001). Fasting and post-meal lipid oxidation (grams/minute) were positively correlated to neonatal birthweight (fasting r = 0.426, p = 0.015; 2-hour r = 0.393, p = 0.026; 4-hour r = 0.540, p = 0.001) and also to neonatal absolute fat mass (fasting r = 0.493, p = 0.004; 2-hour r = 0.450, p = 0.010; 4-hour r = 0.552, p = 0.001). CONCLUSIONS: A better understanding of the metabolic profile of women during pregnancy may be critical in truly understanding a woman\u27s risk of GWG outside the recommendations. GWG counseling during prenatal care may need to be tailored to women based not just on their weight status, but other metabolic characteristics

    Controlled Release of Doxorubicin Loaded within Magnetic Thermo-responsive Nanocarriers under Magnetic and Thermal Actuation in a Microfluidic Channel

    Get PDF
    We report a procedure to grow thermo-responsive polymer shells at the surface of magnetic nanocarriers made of multiple iron oxide superparamagnetic nanoparticles embedded in poly(maleic anhydride-alt-1-ocatadecene) polymer nanobeads. Depending on the comonomers and on their relative composition, tunable phase transition temperatures in the range between 26 and 47 °C under physiological conditions could be achieved. Using a suitable microfluidic platform combining magnetic nanostructures and channels mimicking capillaries of the circulatory system, we demonstrate that thermo-responsive nanobeads are suitable for localized drug delivery with combined thermal and magnetic activation. Below the critical temperature nanobeads are stable in suspension, retain their cargo, and cannot be easily trapped by magnetic fields. Increasing the temperature above the critical temperature causes the aggregation of nanobeads, forming clusters with a magnetic moment high enough to permit their capture by suitable magnetic g..

    "Nanohybrids" based on pH-responsive hydrogels and inorganic nanoparticles for drug delivery and sensor applications.

    Get PDF
    Allyl-PEG capped inorganic NPs, including magnetic iron oxide (IONPs), fluorescent CdSe/ZnS quantum dots (QDs), and metallic gold (AuNPs of 5 and 10 nm) both individually and in combination, were covalently attached to pH-responsive poly(2-vinylpyridine-co-divinylbenzene) nanogels via a facile and robust one-step surfactant-free emulsion polymerization procedure. Control of the NPs associated to the nanogels was achieved by the late injection of the NPs to the polymerization solution at a stage when just polymeric radicals were present. Remarkably, by varying the total amount of NPs injected, the swelling behavior could be affected. Furthermore, the magnetic response as well as the optical features of the nanogels containing either IONPs or QDs could be modified. In addition, a radical quenching in case of gold nanoparticles was observed, thus affecting the final nanogel geometry

    Calibration test of PET scanners in a multi-centre clinical trial on breast cancer therapy monitoring using 18F-FLT.

    Get PDF
    UNLABELLED: A multi-centre trial using PET requires the analysis of images acquired on different systems We designed a multi-centre trial to estimate the value of 18F-FLT-PET to predict response to neoadjuvant chemotherapy in patients with newly diagnosed breast cancer. A calibration check of each PET-CT and of its peripheral devices was performed to evaluate the reliability of the results. MATERIAL AND METHODS: 11 centres were investigated. Dose calibrators were assessed by repeated measurements of a 68Ge certified source. The differences between the clocks associated with the dose calibrators and inherent to the PET systems were registered. The calibration of PET-CT was assessed with an homogeneous cylindrical phantom by comparing the activities per unit of volume calculated from the dose calibrator measurements with that measured on 15 Regions of Interest (ROIs) drawn on 15 consecutive slices of reconstructed filtered back-projection (FBP) images. Both repeatability of activity concentration based upon the 15 ROIs (ANOVA-test) and its accuracy were evaluated. RESULTS: There was no significant difference for dose calibrator measurements (median of difference -0.04%; min = -4.65%; max = +5.63%). Mismatches between the clocks were less than 2 min in all sites and thus did not require any correction, regarding the half life of 18F. For all the PET systems, ANOVA revealed no significant difference between the activity concentrations estimated from the 15 ROIs (median of difference -0.69%; min = -9.97%; max = +9.60%). CONCLUSION: No major difference between the 11 centres with respect to calibration and cross-calibration was observed. The reliability of our 18F-FLT multi-centre clinical trial was therefore confirmed from the physical point of view. This type of procedure may be useful for any clinical trial involving different PET systems

    High-spin States in \u3csup\u3e191, 193\u3c/sup\u3eAu and \u3csup\u3e192\u3c/sup\u3ePt: Evidence for Oblate Deformation and Triaxial Shapes

    Get PDF
    High-spin states of 191, 193Au and 192Pt have been populated in the 186W(11B, xn) and 186W(11B, p4n) reactions, respectively, at a beam energy of 68 MeV and their Îł decay was studied using the YRAST Ball detector array at the Wright Nuclear Structure Laboratory at Yale University. The level scheme of 193Au has been extended up to IĎ€ = 55/2+. New transitions were observed also in 191Au and 192Pt. Particle-plus-Triaxial-Rotor (PTR) and Total Routhian Surface (TRS) calculations were performed to determine the equilibrium deformations of the Au isotopes. The predictions for oblate deformations in these nuclei are in agreement with the experimental data. Development of nonaxial shapes is discussed within the framework of the PTR model
    • …
    corecore