854 research outputs found

    Semi-inclusive bottom-Higgs production at LHC: The complete one-loop electroweak effect in the MSSM

    Full text link
    We present the first complete calculation of the one-loop electroweak effect in the process of semi-inclusive bottom-Higgs production at LHC in the MSSM. The size of the electroweak contribution depends on the choice of the final produced neutral Higgs boson, and can be relevant, in some range of the input parameters. A comparison of the one-loop results obtained in two different renormalization schemes is also performed, showing a very good NLO scheme independence. We further comment on two possible, simpler, approximations of the full NLO result, and on their reliabilty

    NLO QCD corrections to the production of Higgs plus two jets at the LHC

    Full text link
    We present the calculation of the NLO QCD corrections to the associated production of a Higgs boson and two jets, in the infinite top-mass limit. We discuss the technical details of the computation and we show the numerical impact of the radiative corrections on several observables at the LHC. The results are obtained by using a fully automated framework for fixed order NLO QCD calculations based on the interplay of the packages GoSam and Sherpa. The evaluation of the virtual corrections constitutes an application of the d-dimensional integrand-level reduction to theories with higher dimensional operators. We also present first results for the one-loop matrix elements of the partonic processes with a quark-pair in the final state, which enter the hadronic production of a Higgs boson together with three jets in the infinite top-mass approximation.Comment: 9 pages, 7 figures, references added, published in Phys.Lett.

    Seismic reflection data in the Umbria Marche Region: limits and capabilities to unravel the subsurface structure in a seismically active area

    Get PDF
    Before seismic data were made available, the subsurface setting of the Umbria-Marche area was mainly derived from the extrapolation of surface data and from models resulting from analogies with other mountain chains around the world. During the ‘90s industrial seismic data availability considerably increased, allowing the definition of new, previously unknown features. Beside the industrial seismic data availability, a deep crustal, near vertical seismic section trending E-W was acquired (CROP-03) across the Italian peninsula from the Tyrrhenian to the Adriatic coast. The subsurface data defined the compressional deformation style (thin- Vs thick- skinned) and the extensional deformation style. A set of east-dipping low-angle-normal faults, which dissect the previous compressional structures and which are the dominant features controlling the extension of the Apennines were recognised. The subsequent application of the seismic data interpretation to seismotectonic issues, defined in more detail the subsurface geometries of the active faults and the relationships between upper crust structure and seismicity

    Inflammatory Abdominal Aortic Aneurysm (IAAA)

    Get PDF
    Purpose: The aim of this study is to report our experience about the inflammatory abdominal aortic aneurysm (IAAA). Methods: Between January 1999 and January 2008 we treated 8 cases of IAAA. Two patients underwent surgery in emergency. The preoperative diagnostic procedures were ultrasound (US), computed tomography (CT) and intravenous urography (IVU). In 6 elective patients the diagnosis of IAAA was obtained preoperatively. In one case a left hydroureteronephrosis was demonstrated by intravenous urography (IVU). All patients underwent open surgery with midline incision and transperitoneal access. Results: No 30-days mortality occurred. A case of pancreatitis was treated with conservative therapy. All patients had 60-days corticosteroid therapy. Conclusions: Our data suggest that because IAAA have the same rate of rupture of AAA, they need the same preventive treatment as non inflammatory abdominal aortic aneurysm (AAA) The kind of approach OPEN-EVAR should be chosen with the same criteria as AAA, even if EVAR teatment doesn't allow us to obtain the biopsy. Furthermore there are no sufficient evidences about regression of retroperitoneal fibrosis after EVAR treatment. Also the premature onset should be considered in the choice of treatment

    Adsorption of acrolein, propanal, and allyl alcohol on Pd(111): a combined infrared reflection–absorption spectroscopy and temperature programmed desorption study

    No full text
    Atomistic-level understanding of the interaction of α,β-unsaturated aldehydes and their derivatives with late transition metals is of fundamental importance for the rational design of new catalytic materials with the desired selectivity towards C=C vs. C=O bond partial hydrogenation. In this study, we investigate the interaction of acrolein, and its partial hydrogenation products propanal and allyl alcohol, with Pd(111) as a prototypical system. A combination of infrared reflection–absorption spectroscopy (IRAS) and temperature programmed desorption (TPD) experiments was applied under well-defined ultrahigh vacuum (UHV) conditions to obtain detailed information on the adsorption geometries of acrolein, propanal, and allyl alcohol as a function of coverage. We compare the IR spectra obtained for multilayer coverages, reflecting the molecular structure of unperturbed molecules, with the spectra acquired for sub-monolayer coverages, at which the chemical bonds of the molecules are strongly distorted. Coverage-dependent IR spectra of acrolein on Pd(111) point to the strong changes in the adsorption geometry with increasing acrolein coverage. Acrolein adsorbs with the C=C and C=O bonds lying parallel to the surface in the low coverage regime and changes its geometry to a more upright orientation with increasing coverage. TPD studies indicate decomposition of the species adsorbed in the sub-monolayer regime upon heating. Similar strong coverage dependence of the IR spectra were found for propanal and allyl alcohol. For all investigated molecules a detailed assignment of vibrational bands is reported

    A complete one-loop calculation of electroweak supersymmetric effects in tt-channel single top production at LHC

    Full text link
    We have computed the complete one-loop electroweak effects in the MSSM for single top (and single antitop) production in the tt-channel at hadron colliders, generalizing a previous analysis performed for the dominant dtdt final state and fully including QED effects. The results are quite similar for all processes. The overall Standard Model one-loop effect is small, of the few percent size. This is due to a compensation of weak and QED contributions that are of opposite sign. The genuine SUSY contribution is generally quite modest in the mSUGRA scenario. The experimental observables would therefore only practically depend, in this framework, on the CKM WtbWtb coupling.Comment: 25 pages, several eps figures. Update corresponding to published versio

    Type 1A endoleak detachable coil embolization after endovascular aneurysm sealing: Case report

    Get PDF
    Introduction: Endovascular aneurysm sealing (EVAS) with the Nellix system was introduced to reduce endovascular aneurysm repair (EVAR) perioperative complications, especially endoleaks. Herein we report a case of successful type 1A endoleak managed with detachable coils embolization after EVAS. Presentation of case: A 77-year-old male was referred for abdominal pain. The angio-CT scan confirmed the previous EVAS procedure and showed a type Is2 endoleak below the right renal artery resulting in a 2.5 cm aortic blister with contrast medium filling the space between the aortic wall and the endobags. The patient was considered unfit for conventional open surgery and an endovascular approach with coil embolization Concerto Helix Detachable Coil System was chosen under local anesthesia. After intervention, a complete abdominal pain regression was registered. The 12- month CT follow-up showed endoleak sealing and Nellix system stability. Discussion: EVAS has been associated to a high endoleaks and complications incidence when compared to EVAR. The EVAS different device concept led to a different endoleak classification and management. Endoleak management main options include the Nellix system explantation or the Nellix in Nellix application, however these are nearly always not applicable, respectively, due to the high surgical risk condition and the Nellix system availability, especially in emergent setting. Despite the use of coil embolization is controversial, this tool is off-the-shelf and leads to a disease resolution in most of patients without other surgical options. Conclusion: Proximal type Is2 embolization after EVAS is feasible with limited invasiveness

    Automated one-loop calculations with GoSam 2.0

    Full text link
    We present the version 2.0 of the program GoSam, which is a public program package to compute one-loop corrections to multi-particle processes. The extended version of the "Binoth-Les-Houches-Accord" interface to Monte Carlo programs is also implemented. This allows a large flexibility regarding the combination of the code with various Monte Carlo programs to produce fully differential NLO results, including the possibility of parton showering and hadronisation. We describe the new features of the code and illustrate the wide range of applicability for multi-particle processes at NLO, both within and beyond the Standard Model.Comment: 9 pages, talk given at the conference "Loops and Legs in Quantum Field Theory", Weimar, Germany, April 201

    GoSam-2.0: a tool for automated one-loop calculations within the Standard Model and beyond

    Get PDF
    We present the version 2.0 of the program package GoSam for the automated calculation of one-loop amplitudes. GoSam is devised to compute one-loop QCD and/or electroweak corrections to multi-particle processes within and beyond the Standard Model. The new code contains improvements in the generation and in the reduction of the amplitudes, performs better in computing time and numerical accuracy, and has an extended range of applicability. The extended version of the "Binoth-Les-Houches-Accord" interface to Monte Carlo programs is also implemented. We give a detailed description of installation and usage of the code, and illustrate the new features in dedicated examples.Comment: replaced by published version and reference adde
    • …
    corecore