334 research outputs found

    Coherent phenomena in mesoscopic systems

    Full text link
    A mesoscopic system of cylindrical geometry made of a metal or a semiconductor is shown to exhibit features of a quantum coherent state. It is shown that magnetostatic interaction can play an important role in mesoscopic systems leading to an ordered ground state. The temperature TT^{*} below the system exhibits long-range order is determined. The self-consistent mean field approximation of the magnetostatic interaction is performed giving the effective Hamiltonian from which the self-sustaining currents can be obtained. The relation of quantum coherent state in mesoscopic cylinders to other coherent systems like superconductors is discussed.Comment: REVTeX, 4 figures, in print in Supercond. Sci. Techno

    Possibility of long-range order in clean mesoscopic cylinders

    Full text link
    A microscopic Hamiltonian of the magnetostatic interaction is discussed. This long-range interaction can play an important role in mesoscopic systems leading to an ordered ground state. The self-consistent mean field approximation of the magnetostatic interaction is performed to give an effective Hamiltonian from which the spontaneous, self-sustaining currents can be obtained. To go beyond the mean field approximation the mean square fluctuation of the total momentum is calculated and its influence on self-sustaining currents in mesoscopic cylinders with quasi-1D and quasi-2D conduction is considered. Then, by the use of the microscopic Hamiltonian of the magnetostatic interaction for a set of stacked rings, the problem of long-range order is discussed. The temperature TT^{*} below which the system is in an ordered state is determined.Comment: 14 pages, REVTeX, 5 figures, in print in Phys. Rev.

    Electromagnetic Calorimeter for HADES

    Full text link
    We propose to build the Electromagnetic calorimeter for the HADES di-lepton spectrometer. It will enable to measure the data on neutral meson production from nucleus-nucleus collisions, which are essential for interpretation of dilepton data, but are unknown in the energy range of planned experiments (2-10 GeV per nucleon). The calorimeter will improve the electron-hadron separation, and will be used for detection of photons from strange resonances in elementary and HI reactions. Detailed description of the detector layout, the support structure, the electronic readout and its performance studied via Monte Carlo simulations and series of dedicated test experiments is presented. The device will cover the total area of about 8 m^2 at polar angles between 12 and 45 degrees with almost full azimuthal coverage. The photon and electron energy resolution achieved in test experiments amounts to 5-6%/sqrt(E[GeV]) which is sufficient for the eta meson reconstruction with S/B ratio of 0.4% in Ni+Ni collisions at 8 AGeV. A purity of the identified leptons after the hadron rejection, resulting from simulations based on the test measurements, is better than 80% at momenta above 500 MeV/c, where time-of-flight cannot be used.Comment: 40 pages, 38 figures version2 - the time schedule added, information about PMTs in Sec.III update

    Spin measurements for 147Sm+n resonances: Further evidence for non-statistical effects

    Full text link
    We have determined the spins J of resonances in the 147Sm(n,gamma) reaction by measuring multiplicities of gamma-ray cascades following neutron capture. Using this technique, we were able to determine J values for all but 14 of the 140 known resonances below En = 1 keV, including 41 firm J assignments for resonances whose spins previously were either unknown or tentative. These new spin assignments, together with previously determined resonance parameters, allowed us to extract separate level spacings and neutron strength functions for J = 3 and 4 resonances. Furthermore, several statistical test of the data indicate that very few resonances of either spin have been missed below En = 700eV. Because a non-statistical effect recently was reported near En = 350 eV from an analysis of 147Sm(n,alpha) data, we divided the data into two regions; 0 < En < 350 eV and 350 < En < 700 eV. Using neutron widths from a previous measurement and published techniques for correcting for missed resonances and for testing whether data are consistent with a Porter-Thomas distribution, we found that the reduced-neutron-width distribution for resonances below 350 eV is consistent with the expected Porter-Thomas distribution. On the other hand, we found that reduced-neutron-width data in the 350 < En < 700 eV region are inconsistent with a Porter-Thomas distribution, but in good agreement with a chi-squared distribution having two or more degrees of freedom. We discuss possible explanations for these observed non-statistical effects and their possible relation to similar effects previously observed in other nuclides.Comment: 40 pages, 13 figures, accepted by Phys. Rev.

    Dark resonances as a probe for the motional state of a single ion

    Full text link
    Single, rf-trapped ions find various applications ranging from metrology to quantum computation. High-resolution interrogation of an extremely weak transition under best observation conditions requires an ion almost at rest. To avoid line-broadening effects such as the second order Doppler effect or rf heating in the absence of laser cooling, excess micromotion has to be eliminated as far as possible. In this work the motional state of a confined three-level ion is probed, taking advantage of the high sensitivity of observed dark resonances to the trapped ion's velocity. Excess micromotion is controlled by monitoring the dark resonance contrast with varying laser beam geometry. The influence of different parameters such as the cooling laser intensity has been investigated experimentally and numerically

    Performance of Long Modules of Silicon Microstrip Detectors

    Get PDF
    This note describes the performance of modules assembled with up to twelve silicon microstrip detectors. These modules were built for the instrumented Silicon Target (STAR) that has been installed in the NOMAD spectrometer. Laboratory and test beam results are compared with model predictions. For a module of nine detectors, test beam results indicate a signal--to--noise ratio of 19, a hit finding efficiency of 99.8\% and a spatial resolution of 6.0 μ\mum. Laboratory measurements indicate that modules of twelve detectors exhibit a signal--to--noise ratio of the order of 16

    The s Process: Nuclear Physics, Stellar Models, Observations

    Full text link
    Nucleosynthesis in the s process takes place in the He burning layers of low mass AGB stars and during the He and C burning phases of massive stars. The s process contributes about half of the element abundances between Cu and Bi in solar system material. Depending on stellar mass and metallicity the resulting s-abundance patterns exhibit characteristic features, which provide comprehensive information for our understanding of the stellar life cycle and for the chemical evolution of galaxies. The rapidly growing body of detailed abundance observations, in particular for AGB and post-AGB stars, for objects in binary systems, and for the very faint metal-poor population represents exciting challenges and constraints for stellar model calculations. Based on updated and improved nuclear physics data for the s-process reaction network, current models are aiming at ab initio solution for the stellar physics related to convection and mixing processes. Progress in the intimately related areas of observations, nuclear and atomic physics, and stellar modeling is reviewed and the corresponding interplay is illustrated by the general abundance patterns of the elements beyond iron and by the effect of sensitive branching points along the s-process path. The strong variations of the s-process efficiency with metallicity bear also interesting consequences for Galactic chemical evolution.Comment: 53 pages, 20 figures, 3 tables; Reviews of Modern Physics, accepte

    Verification of electromagnetic calorimeter concept for the HADES spectrometer

    Get PDF
    The HADES spectrometer currently operating on the beam of SIS18 accelerator in GSI will be moved to a new position in the CBM cave of the future FAIR complex. Electromagnetic calorimeter (ECAL) will enable the HADES@FAIR experiment to measure data on neutral meson production in heavy ion collisions at the energy range of 2-10 A GeVon the beam of the new accelerator SIS100. Calorimeter will be based on 978 massive lead glass modules read out by photomultipliers and a novel front-end electronics. Secondary gamma beam with energies ranging from 81 MeV up to 1399 MeV from MAMI-C Mainz facility was used to verify selected technical solutions. Relative energy resolution was measured using modules with three different types of photomultipliers. Two types of developed front-end electronics as well as energy leakage between neighbouring modules under parallel and declined gamma beams were studied in detail

    Gene Expression Analysis in Rats Treated with Experimental Acetyl-Coenzyme A Carboxylase Inhibitors Suggests Interactions with the Peroxisome Proliferator-Activated Receptor ␣ Pathway

    Get PDF
    ABSTRACT Acetyl CoA carboxylase (ACC) 2, which catalyzes the carboxylation of acetyl-CoA to form malonyl-CoA, has been identified as a potential target for type 2 diabetes and obesity. Small-molecule inhibitors of ACC2 would be expected to reduce de novo lipid synthesis and increase lipid oxidation. Treatment of ob/ob mice with compound A-908292 (S) ({(S)-3-[2-(4-isopropoxy-phenoxy)-thiazol-5-yl]-1-methylprop-2-ynyl}-carbamic acid methyl ester), a small-molecule inhibitor with an IC 50 of 23 nM against ACC2, resulted in a reduction of serum glucose and triglyceride levels. However, compound A-875400 (R) ({(R)-3-[2-(4-isopropoxy-phenoxy)-thiazol-5-yl]-1-methyl-prop-2-ynyl}-carbamic acid methyl ester), an inactive enantiomer of A-908292 (S) with approximately 50-fold less activity against ACC2, also caused a similar reduction in glucose and triglycerides, suggesting that the glucose-lowering effects in ob/ob mice may be mediated by other metabolic pathways independent of ACC2 inhibition. To characterize the pharmacological activity of these experimental compounds at a transcriptional level, rats were orally dosed for 3 days with either A-908292 (S) or A-875400 (R), and gene expression analysis was performed. Gene expression analysis of livers showed that treatment with A-908292 (S) or A-875400 (R) resulted in gene expression profiles highly similar to known peroxisome proliferator-activated receptor (PPAR)-␣ activators. The results suggest that, in vivo, both A-908292 (S) and A-875400 (R) stimulated the PPAR-␣-dependent signaling pathway. These results were further supported by both an in vitro genomic evaluation using rat hepatocytes and immunohistochemical evaluation using 70-kDa peroxisomal membrane protein. Overall, the gene expression analysis suggests a plausible mechanism for the similar pharmacological findings with active and inactive enantiomers of an ACC2 inhibitor
    corecore