329 research outputs found
In situ measurement of the electron drift velocity for upcoming directional Dark Matter detectors
Three-dimensional track reconstruction is a key issue for directional Dark
Matter detection and it requires a precise knowledge of the electron drift
velocity. Magboltz simulations are known to give a good evaluation of this
parameter. However, large TPC operated underground on long time scale may be
characterized by an effective electron drift velocity that may differ from the
value evaluated by simulation. In situ measurement of this key parameter is
hence needed as it is a way to avoid bias in the 3D track reconstruction. We
present a dedicated method for the measurement of the electron drift velocity
with the MIMAC detector. It is tested on two gas mixtures: CF4 and CF4 + CHF3.
The latter has been chosen for the MIMAC detector as we expect that adding CHF3
to pure CF4 will lower the electron drift velocity. This is a key point for
directional Dark Matter as the track sampling along the drift field will be
improved while keeping almost the same Fluorine content of the gas mixture. We
show that the drift velocity at 50 mbar is reduced by a factor of about 5 when
adding 30% of CHF3.Comment: 19 pages, 14 figures. Minor corrections, matches published version in
JINS
Measurement of the electron drift velocity for directional dark matter detectors
Three-dimensional track reconstruction is a key issue for directional Dark
Matter detection. It requires a precise knowledge of the electron drift
velocity. Magboltz simulations are known to give a good evaluation of this
parameter. However, large TPC operated underground on long time scale may be
characterized by an effective electron drift velocity that may differ from the
value evaluated by simulation. In situ measurement of this key parameter is
hence a way to avoid bias in the 3D track reconstruction. We present a
dedicated method for the measurement of the electron drift velocity with the
MIMAC detector. It is tested on two gas mixtures : and . We also show that adding allows us to lower the
electron drift velocity while keeping almost the same Fluorine content of the
gas mixture.Comment: Proceedings of the 4th international conference on Directional
Detection of Dark Matter (CYGNUS 2013), 10-12 June 2013, Toyama, Japa
Radio Detection of Cosmic Ray Air Showers with Codalema
Studies of the radio detection of Extensive Air Showers is the goal of the
demonstrative experiment CODALEMA. Previous analysis have demonstrated that
detection around eV was achieved with this set-up. New results
allow for the first time to study the topology of the electric field associated
to EAS events on a event by event basis.Comment: 6 pages, 4 figures Proceedings of the Rencontres de Moriond, Very
High Energy Phenomena in the Universe, La Thuile, Italy (March 12-19, 2005
Radio Detection of Extensive Air Showers with CODALEMA
The principle and performances of the CODALEMA experimental device, set up to
study the possibility of high energy cosmic rays radio detection, are
presented. Radio transient signals associated to cosmic rays have been
identified, for which arrival directions and shower's electric field topologies
have been extracted from the antenna signals. The measured rate, about 1 event
per day, corresponds to an energy threshold around 5.10^16 eV. These results
allow to determine the perspectives offered by the present experimental design
for radiodetection of UHECR at a larger scale.Comment: 4 pages and 3 figures. To appear in the Proceedings of the 29th ICRC,
Pune (2005
MIMAC: MIcro-tpc MAtrix of Chambers for dark matter directional detection
Directional detection of non-baryonic Dark Matter is a promising search
strategy for discriminating WIMP events from neutrons, the ultimate background
for dark matter direct detection. This strategy requires both a precise
measurement of the energy down to a few keV and 3D reconstruction of tracks
down to a few mm. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has
developed in the last years an original prototype detector based on the direct
coupling of large pixelized micromegas with a special developed fast
self-triggered electronics showing the feasibility of a new generation of
directional detectors. The first bi-chamber prototype has been installed at
Modane, underground laboratory in June 2012. The first undergournd background
events, the gain stability and calibration are shown. The first spectrum of
nuclear recoils showing 3D tracks coming from the radon progeny is presented.Comment: Proceedings of the 4th International Conference on Directional Dark
Matter Detection CYGNUS2013, held in Toyoma (Japan), June 201
Radio Detection of Cosmic Ray Extensive Air Showers: present status of the CODALEMA experiment
Data acquisition and analysis for the CODALEMA experiment, in operation for
more than one year, has provided improved knowledge of the characteristics of
this new device. At the same time, an important effort has been made to develop
processing techniques for extracting transient signals from data containing
interference.Comment: september 200
Radiodetection of Cosmic Ray Extensive Air Showers
We present the characteristics and performance of a demonstration experiment
devoted to the observation of ultra high- energy cosmic ray extensive air
showers using a radiodetection technique. In a first step, one antenna narrowed
band filtered acting as trigger, with a 4 threshold above sky
background-level, was used to tag any radio transient in coincidence on the
antenna array. Recently, the addition of 4 particle detectors has allowed us to
observe cosmic ray events in coincidence with antennas
Trigger and readout electronics for the STEREO experiment
The STEREO experiment will search for a sterile neutrino by measuring the
anti-neutrino energy spectrum as a function of the distance from the source,
the ILL nuclear reactor. A dedicated electronic system, hosted in a single
microTCA crate, was designed for this experiment. It performs triggering in two
stages with various selectable conditions, processing and readout via UDP/IPBUS
of 68 photomultiplier signals continuously digitized at 250 MSPS. Additionally,
for detector performance monitoring, the electronics allow on-line calibration
by driving LED synchronously with the data acquisition. This paper describes
the electronics requirements, architecture and the performances achieved.Comment: Topical Workshop on Electronics for Particle Physics (TWEPP) 2015,
Lisboa. 9 pages, 9 figure
- …