209 research outputs found
Is contrast-enhanced US alternative to spiral CT in the assessment of treatment outcome of radiofrequency ablation in hepatocellular carcinoma?
Purpose: The present study was conducted to assess the efficacy of contrast-enhanced ultrasound with low mechanical index in evaluating the response of percutaneous radiofrequency ablation treatment of hepatocellular carcinoma by comparing it with 4-row spiral computed tomography. Materials and Methods: 100 consecutive patients (65 men and 35 women; age range: 62 – 76 years) with solitary hepatocellular carcinomas (mean lesion diameter: 3.7cm± 1.1cm SD) underwent internally cooled radiofrequency ablation. Therapeutic response was evaluated at one month after the treatment with triple-phasic contrast-enhanced spiral CT and low-mechanical index contrast-enhanced ultrasound following bolus injection of 2.4 ml of Sonovue (Bracco, Milan). 60 out of 100 patients were followed up for another 3 months. Contrast-enhanced sonographic studies were reviewed by two blinded radiologists in consensus. Sensitivity, specificity, NPV and PPV of contrast-enhanced ultrasound examination were determined. Results: After treatment, contrast-enhanced ultrasound identified persistent signal enhancement in 24 patients (24%), whereas no intratumoral enhancement was detected in the remaining 76 patients (76%). Using CT imaging as gold standard, the sensitivity, specificity, NPV, and PPV of contrast enhanced ultrasound were 92.3% (95% CI = 75.9 – 97.9%), 100% (95% CI = 95.2 – 100%), 97.4% (95% CI = 91.1 – 99.3%), and 100% (95% CI = 86.2 – 100%). Conclusion: Contrast-enhanced ultrasound with low mechanical index using Sonovue is a feasible tool in evaluating the response of hepatocellular carcinoma to radiofrequency ablation. Accuracy is comparable to 4-row spiral CT
EFSUMB Statement on Medical Student Education in Ultrasound [long version]
Publisher Copyright: © 2016 Georg Thieme Verlag. All rights reserved.The European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) recommends that ultrasound should be used systematically as an easy accessible and instructive educational tool in the curriculum of modern medical schools. Medical students should acquire theoretical knowledge of the modality and hands-on training should be implemented and adhere to evidence-based principles. In this paper we report EFSUMB policy statements on medical student education in ultrasound that in a short version is already published in Ultraschall in der Medizin 1.publishersversionPeer reviewe
Subclinical remodelling of draining lymph node structure in early and established rheumatoid arthritis assessed by power Doppler ultrasonography
OBJECTIVE: To investigate the suitability of power Doppler ultrasonography (PD-US) for the assessment of lymph node (LN) status in RA, evaluating the existence of structural and dynamic modifications in well-characterized stages of the disease.
METHODS:
Ten patients with active disease and five patients in clinical remission underwent complete clinical and PD-US examination of hands, wrists, axillary and cervical LNs on the same day. Synovitis and PD were graded 0-3. LN assessment included maximum short axis, cortical hypertrophy (CH) and PD signal distribution. All patients with active disease were re-evaluated prospectively 3 months after initiation of therapy.
RESULTS:
PD-US signs of axillary LN remodelling were observed in 7 out of 10 patients with active disease despite the absence of clinical lymphoadenopathy. Subclinical alterations were detected in both early untreated RA and in established disease. Characteristic structural changes consisted of hypertrophy of the LN cortex and PD signal amplification in cortical and hilar regions. Cervical LNs in active disease and axillary LNs in clinical remission were unaffected. LN PD amplification returned to normal ranges in patients with baseline alterations re-evaluated 3 months after therapy with TNF-\u3b1 blocking agents and/or MTX.
CONCLUSION:
Draining LNs in RA are subjected to subclinical intra-parenchymal changes and vascular flow modulation detectable by PD-US. Sonographic signs of LN involvement associate with disease activity and are reversible upon treatment. These data point at LN reactivity as a dynamic component of RA inflammatory cascade and an attractive platform to be explored in prognostic and response to therapy evaluation
MR Micro-Neurography and a Segmentation Protocol Applied to Diabetic Neuropathy
The aim of this study was to assess with MRI morphometric ultrastructural changes in nerves affected by diabetic peripheral neuropathy (DPN). We used an MR micro-neurography imaging protocol and a semiautomated technique of tissue segmentation to visualize and measure the volume of internal nerve components, such as the epineurium and nerve fascicles. The tibial nerves of 16 patients affected by DPN and of 15 healthy volunteers were imaged. Nerves volume (NV), fascicles volume (FV), fascicles to nerve ratio (FNR), and nerves cross-sectional areas (CSA) were obtained. In patients with DPN the NV was increased and the FNR was decreased, as a result of an increase of the epineurium (FNR in diabetic neuropathy 0,665; in controls 0,699, p=0,040). CSA was increased in subjects with DPN (12,84 mm2 versus 10,22 mm2, p=0,003). The FV was increased in patients with moderate to severe DPN. We have demonstrated structural changes occurring in nerves affected by DPN, which otherwise are assessable only with an invasive biopsy. MR micro-neurography appears to be suitable for the study of microscopic changes in tibial nerves of diabetic patients
The EFSUMB Guidelines and Recommendations for the Clinical Practice of Elastography in Non-Hepatic Applications: Update 2018
This manuscript describes the use of ultrasound elastography, with the exception of liver applications, and represents an update of the 2013 EFSUMB (European Federation of Societies for Ultrasound in Medicine and Biology) Guidelines and Recommendations on the clinical use of elastography
The EFSUMB Guidelines and Recommendations for the Clinical Practice of Elastography in Non-Hepatic Applications : Update 2018
Funding Information: Odd Helge Gilja: Advisory Board/Consultant fee from: AbbVie, Bracco, GE Healthcare, Samsung, and Takeda Paul S. Sidhu: Speaker honoraria, Bracco, Siemens, Samsung, Hiatchi, GE and Philips Christoph F. Dietrich: Speaker honoraria, Bracco, Hitachi, GE, Mindray, Supersonic, Pentax, Olympus, Fuji, Boston Scientific, AbbVie, Falk Foundation, Novartis, Roche; Advisory, Board Member, Hitachi, Mindray, Siemens; Research grant, GE, Mindray, SuperSonic Vito Cantisani: Speaker honoraria, Canon/Toshiba, Bracco, Samsung Dominique Amy: Speaker honoraria, Hitachi, Supersonic, EpiSonica Marco Brock: Speaker honoraria, Hitachi Fabrizio Calliada: Speaker honoraria, Bracco, Hitachi, Shenshen Mindray Dirk Andre Clevert: Speaker honoraria, Siemens, Samsung, GE, Bracco, Philips; Advisory Board, Siemens, Samsung, Bracco, Philips Jean-Michel Correas: Speaker honoraria, Hitachi-Aloka, Canon/Toshiba, Philips, Supersonic, Bracco, Guerbet; Research collaboration, Bracco Sonocap, Guerbet NsSafe and Secure protocols Mirko D’Onofrio: Speaker honoraria, Siemens, Bracco, Hitachi; Advisory Board Siemens, Bracco Andre Farrokh: Speaker honoraria, Hitachi Pietro Fusaroli: Speaker honoraria, Olympus Roald Flesland Havre: Speaker honoraria, GE Healthcare, Conference participation support from Pharmacosmos, Ultrasound equipment from Samsung Medison André Ignee: Speaker honoraria: Siemens, Canon/Toshiba, Hitachi, Boston Scientific, Bracco, Supersonic, Abbvie Christian Jenssen: Speaker honoraria, Bracco, Hitachi, Canon/Toshiba, Falk Foundation, Covidien; Research grant, Novartis Maija Radzina: Speaker honoraria, Bracco, Canon/Toshiba Luca Sconfienza: Travel grants from Bracco Imaging Italia Srl, Esaote SPA, Abiogen SPA, Fidia Middle East. Speaker honoraria from Fidia Middle East Ioan Sporea: Speaker honoraria, Philips, GE, Canon/Toshiba; Advisory Board Member, Siemens; Congress participation support, Siemens Mickael Tanter: Speaker honoraria, Supersonic; Co Founder and shareholder, Supersonic; Research collaboration, Supersonic Peter Vilmann: Speaker honoraria, Pentax, Norgine; Advisory Board, Boston Scientific; Consultancy MediGlobe The following members declared no conflicts of interest: Adrian Săftoiu, Michael Bachmann Nielsen, Flaviu Bob, Jörg Bojunga, Caroline Ewertsen, Michael Hocke, Andrea Klauser, Christian Kollmann, Kumar V Ramnarine, Carolina Solomon, Daniela Fodor, Horia Ștefănescu Publisher Copyright: © 2019 Georg Thieme Verlag KG Stuttgart New York.This manuscript describes the use of ultrasound elastography, with the exception of liver applications, and represents an update of the 2013 EFSUMB (European Federation of Societies for Ultrasound in Medicine and Biology) Guidelines and Recommendations on the clinical use of elastography.Peer reviewe
How to perform Contrast-Enhanced Ultrasound (CEUS)
"How to perform contrast-enhanced ultrasound (CEUS)" provides general advice on the use of ultrasound contrast agents (UCAs) for clinical decision-making and reviews technical parameters for optimal CEUS performance. CEUS techniques vary between centers, therefore, experts from EFSUMB, WFUMB and from the CEUS LI-RADS working group created a discussion forum to standardize the CEUS examination technique according to published evidence and best personal experience. The goal is to standardise the use and administration of UCAs to facilitate correct diagnoses and ultimately to improve the management and outcomes of patients
- …