70 research outputs found

    TIR-based dynamic liquid-level and flow-rate sensing and its application on centrifugal microfluidic platforms

    Get PDF
    For the first time we present a technique for the spatio-temporally resolved localization of liquid-gas interfaces on centrifugal microfluidic platforms based on total internal reflection (TIR) at the channel wall. The simple setup consists of a line laser and a linear image sensor array mounted in a stationary instrument. Apart from identifying the presence of (usually unwanted) gas bubbles, the here described online meniscus detection allows to measure liquid volumes with a high precision of 1.9%. Additionally, flow rates and viscosities (range: 1-10.7 mPa s) can be sensed even during rotation at frequencies up to 30 Hz with a precision of 4.7% and 4.3%, respectively

    A one-compartment, direct glucose fuel cell for powering long-term medical implants

    Get PDF
    We present the operational concept, microfabrication, and electrical performance of an enzyme-less direct glucose fuel cell for harvesting the chemical energy of glucose from body fluids. The spatial concentrations of glucose and oxygen at the electrodes of the one-compartment setup are established by self-organization, governed by the balance of electro-chemical depletion and membrane diffusion. Compared to less stable enzymatic and immunogenic microbial fuel cells, this robust approach excels with an extended life time, the amenability to sterilization and biocompatibility, showing up a clear route towards an autonomous power supply for long-term medical implants without the need of surgical replacement and external refueling. Operating in physiological phosphate buffer solution containing 0.1 wt% glucose and having a geometrical cathode area of 10 cm2, our prototype already delivers 20 ” W peak power over a period of 7 days

    Aliquoting structure for centrifugal microfluidics based on a new pneumatic valve

    Get PDF
    We present a new microvalve that can be monolithically integrated in centrifugally driven lab-on-a-chip systems. In contrast to existing operation principles that use hydrophobic patches, geometrically defined capillary stops or siphons, here we present a pneumatic principle. It needs neither additional local coatings nor expensive micro sized geometries. The valve is controlled by the spinning frequency and can be switched to be open when the centrifugal pressure overcomes the pneumatic pressure inside an unvented reaction cavity. We designed and characterized valves ranging in centrifugal burst pressure from 6700 Pa to 2100 Pa. Based on this valving principle we present a new structure for aliquoting of liquids. We experimentally demonstrated this by splitting 105 muL volumes into 16 aliquots with a volume CV of 3 %

    A surface mountable glucose fuel cell for medical implants

    Get PDF
    We present an enzymeless, surface mountable glucose fuel cell based on abiotic catalysts. The device is intended as an energy harvesting implantable power supply for low power medical implants and sensors. After 50 days of operation in physiological glucose solution the fuel cell exhibited a stable performance of 1.1 muW/cm2. The demonstrated lifetime of our glucose fuel cell therefore already exceeds the maximum lifetime reported for devices based on enzymatic catalysts. This renders the concept a promising approach for the development of autonomous and sustainable power supply systems for long- term medical implants

    An environmental control box for serial crystallography enables multi-dimensional experiments

    Get PDF
    We present a new environmental enclosure for fixed-target, serial crystallography enabling full control of both the temperature and humidity. While maintaining the relative humidity to within a percent, this enclosure provides access to X-ray diffraction experiments in a wide temperature range from below 10 °C to above 80 °C. Coupled with the LAMA method, time-resolved serial crystallography experiments can now be carried out at truly physiological temperatures, providing fundamentally new insight into protein function. Using the hyperthermophile enzyme xylose isomerase, we demonstrate changes in the electron density as a function of increasing temperature and time. This method provides the necessary tools to successfully carry out multi-dimensional serial crystallography

    Homogeneous batch micro-crystallization of proteins from ammonium sulfate

    Get PDF
    The emergence of X-ray free-electron lasers has led to the development of serial macromolecular crystallography techniques, making it possible to study smaller and more challenging crystal systems and to perform time-resolved studies on fast time scales. For most of these studies the desired crystal size is limited to a few micrometres, and the generation of large amounts of nanocrystals or microcrystals of defined size has become a bottleneck for the wider implementation of these techniques. Despite this, methods to reliably generate microcrystals and fine-tune their size have been poorly explored. Working with three different enzymes, L-aspartate alpha-decarboxylase, copper nitrite reductase and copper amine oxidase, the precipitating properties of ammonium sulfate were exploited to quickly transition from known vapour-diffusion conditions to reproducible, large-scale batch crystallization, circumventing the tedious determination of phase diagrams. Furthermore, the specific ammonium sulfate concentration was used to fine-tune the crystal size and size distribution. Ammonium sulfate is a common precipitant in protein crystallography, making these findings applicable to many crystallization systems to facilitate the production of large amounts of microcrystals for serial macromolecular crystallography experiments.Peer reviewe

    Experimental evidence for fast cluster formation of chain oxygen vacancies in YBa2Cu3O7-d being at the origin of the fishtail anomaly

    Full text link
    We report on three different and complementary measurements, namely magnetisation measurements, positron annihilation spectroscopy and NMR measurements, which give evidence that the formation of oxygen vacancy clusters is on the origin of the fishtail anomaly in YBa2Cu3O7-d. While in the case of YBa2Cu3O7.0 the anomaly is intrinsically absent, it can be suppressed in the optimally doped state where vacancies are present. We therefore conclude that the single vacancies or point defects can not be responsible for this anomaly but that clusters of oxygen vacancies are on its origin.Comment: 10 pages, 4 figures, submitted to PR

    Millisecond cryo-trapping by the spitrobot crystal plunger simplifies time-resolved crystallography

    Get PDF
    We introduce the spitrobot, a protein crystal plunger, enabling reaction quenching via cryo-trapping with millisecond time-resolution. Canonical micromesh loops are mounted on an electropneumatic piston, reactions are initiated via the liquid application method (LAMA), and finally intermediate states are cryo-trapped in liquid nitrogen. We demonstrate binding of several ligands in microcrystals of three enzymes, and trapping of reaction intermediates and conformational changes in macroscopic crystals of tryptophan synthase

    VectorDisk: a microfluidic platform integrating diagnostic markers for evidence-based mosquito control

    Get PDF
    Effective mosquito monitoring relies on the accurate identification and characterization of the target population. Since this process requires specialist knowledge and equipment that is not widely available, automated field-deployable systems are highly desirable. We present a centrifugal microfluidic cartridge, the VectorDisk, which integrates TaqMan PCR assays in two feasibility studies, aiming to assess multiplexing capability, specificity, and reproducibility in detecting disk-integrated vector-related assays. In the first study, pools of 10 mosquitoes were used as samples. We tested 18 disks with 27 DNA and RNA assays each, using a combination of multiple microfluidic chambers and detection wavelengths (geometric and color multiplexing) to identify mosquito and malaria parasite species as well as insecticide resistance mechanisms. In the second study, purified nucleic acids served as samples to test arboviral and malaria infective mosquito assays. Nine disks were tested with 14 assays each. No false positive results were detected on any of the disks. The coe cient of variation in reproducibility tests was <10%. The modular nature of the platform, the easy adaptation of the primer/probe panels, the cold chain independence, the rapid (2-3 h) analysis, and the assay multiplexing capacity are key features, rendering the VectorDisk a potential candidate for automated vector analysis

    A Glucose Fuel Cell for Implantable Brain–Machine Interfaces

    Get PDF
    We have developed an implantable fuel cell that generates power through glucose oxidation, producing steady-state power and up to peak power. The fuel cell is manufactured using a novel approach, employing semiconductor fabrication techniques, and is therefore well suited for manufacture together with integrated circuits on a single silicon wafer. Thus, it can help enable implantable microelectronic systems with long-lifetime power sources that harvest energy from their surrounds. The fuel reactions are mediated by robust, solid state catalysts. Glucose is oxidized at the nanostructured surface of an activated platinum anode. Oxygen is reduced to water at the surface of a self-assembled network of single-walled carbon nanotubes, embedded in a Nafion film that forms the cathode and is exposed to the biological environment. The catalytic electrodes are separated by a Nafion membrane. The availability of fuel cell reactants, oxygen and glucose, only as a mixture in the physiologic environment, has traditionally posed a design challenge: Net current production requires oxidation and reduction to occur separately and selectively at the anode and cathode, respectively, to prevent electrochemical short circuits. Our fuel cell is configured in a half-open geometry that shields the anode while exposing the cathode, resulting in an oxygen gradient that strongly favors oxygen reduction at the cathode. Glucose reaches the shielded anode by diffusing through the nanotube mesh, which does not catalyze glucose oxidation, and the Nafion layers, which are permeable to small neutral and cationic species. We demonstrate computationally that the natural recirculation of cerebrospinal fluid around the human brain theoretically permits glucose energy harvesting at a rate on the order of at least 1 mW with no adverse physiologic effects. Low-power brain–machine interfaces can thus potentially benefit from having their implanted units powered or recharged by glucose fuel cells
    • 

    corecore