39 research outputs found

    Recurrence of primary sclerosing cholangitis after liver transplantation – analysing the European Liver Transplant Registry and beyond

    Get PDF
    Liver transplantation for primary sclerosing cholangitis (PSC) can be complicated by recurrence of PSC (rPSC). This may compromise graft survival but the effect on patient survival is less clear. We investigated the effect of post-transplant rPSC on graft and patient survival in a large European cohort. Registry data from the European Liver Transplant Registry regarding all first transplants for PSC between 1980 and 2015 were supplemented with detailed data on rPSC from 48 out of 138 contributing transplant centres, involving 1,549 patients. Bayesian proportional hazards models were used to investigate the impact of rPSC and other covariates on patient and graft survival. Recurrence of PSC was diagnosed in 259 patients (16.7%) after a median follow-up of 5.0 years (quantile 2.5%-97.5%: 0.4–18.5), with a significant negative impact on both graft (HR 6.7; 95% CI 4.9–9.1) and patient survival (HR 2.3; 95% CI 1.5–3.3). Patients with rPSC underwent significantly more re-transplants than those without rPSC (OR 3.6, 95% CI 2.7–4.8). PSC recurrence has a negative impact on both graft and patient survival, independent of transplant-related covariates. Recurrence of PSC leads to higher number of re-transplantations and a 33% decrease in 10-year graft survival

    Strict selection alone of patients undergoing liver transplantation for hilar cholangiocarcinoma is associated with improved survival

    Get PDF
    Liver transplantation for hilar cholangiocarcinoma (hCCA) has regained attention since the Mayo Clinic reported their favorable results with the use of a neo-adjuvant chemoradiation protocol. However, debate remains whether the success of the protocol should be attributed to the neo-adjuvant therapy or to the strict selection criteria that are being applied. The aim of this study was to investigate the value of patient selection alone on the outcome of liver transplantation for hCCA. In this retrospective study, patients that were transplanted for hCCA between1990 and 2010 in Europe were identified using the European Liver Transplant Registry (ELTR). Twenty-one centers reported 173 patients (69%) of a total of 249 patients in the ELTR. Twenty-six patients were wrongly coded, resulting in a study group of 147 patients. We identified 28 patients (19%) who met the strict selection criteria of the Mayo Clinic protocol, but had not undergone neo-adjuvant chemoradiation therapy. Five-year survival in this subgroup was 59%, which is comparable to patients with pretreatment pathological confirmed hCCA that were transplanted after completion of the chemoradiation protocol at the Mayo Clinic. In conclusion, although the results should be cautiously interpreted, this study suggests that with strict selection alone, improved survival after transplantation can be achieved, approaching the Mayo Clinic experience

    Defining Major Surgery: A Delphi Consensus Among European Surgical Association (ESA) Members

    Get PDF
    Background: Major surgery is a term frequently used but poorly defined. The aim of the present study was to reach a consensus in the definition of major surgery within a panel of expert surgeons from the European Surgical Association (ESA). Methods: A 3-round Delphi process was performed. All ESA members were invited to participate in the expert panel. In round 1, experts were inquired by open- and closed-ended questions on potential criteria to define major surgery. Results were analyzed and presented back anonymously to the panel within next rounds. Closed-ended questions in round 2 and 3 were either binary or statements to be rated on a Likert scale ranging from 1 (strong disagreement) to 5 (strong agreement). Participants were sent 3 reminders at 2-week intervals for each round. 70% of agreement was considered to indicate consensus. Results: Out of 305 ESA members, 67 (22%) answered all the 3 rounds. Significant comorbidities were the only preoperative factor retained to define major surgery (78%). Vascular clampage or organ ischemia (92%), high intraoperative blood loss (90%), high noradrenalin requirements (77%), long operative time (73%) and perioperative blood transfusion (70%) were procedure-related factors that reached consensus. Regarding postoperative factors, systemic inflammatory response (76%) and the need for intensive or intermediate care (88%) reached consensus. Consequences of major surgery were high morbidity (>30% overall) and mortality (>2%). Conclusion: ESA experts defined major surgery according to extent and complexity of the procedure, its pathophysiological consequences and consecutive clinical outcomes

    Navigated laparoscopic microwave ablation of tumour mimics in pig livers: a randomized ex-vivo experimental trial

    No full text
    Background!#!In order to efficiently perform laparoscopic microwave ablation of liver tumours precise positioning of the ablation probe is mandatory. This study evaluates the precision and ablation accuracy using the innovative laparoscopic stereotactic navigation system CAS-One-SPOT in comparison to 2d ultrasound guided laparoscopic ablation procedures.!##!Methods!#!In a pig liver ablation model four surgeons, experienced (n = 2) and inexperienced (n = 2) in laparoscopic ablation procedures, were randomized for 2d ultrasound guided laparoscopic or stereotactic navigated laparoscopic ablation procedures. Each surgeon performed a total of 20 ablations. Total attempts of needle placements, time from tumor localization till beginning of ablation and ablation accuracy were analyzed.!##!Results!#!The use of the laparoscopic stereotactic navigation system led to a significant reduction in total attempts of needle placement. The experienced group of surgeons reduced the mean number of attempts from 2.75 ± 2.291 in the 2d ultrasound guided ablation group to 1.45 ± 1.191 (p = 0.0302) attempts in the stereotactic navigation group. Comparable results could be observed in the inexperienced group with a reduction of 2.5 ± 1.50 to 1.15 ± 0.489 (p = 0.0005). This was accompanied by a significant time saving from 101.3 ± 112.1 s to 48.75 ± 27.76 s (p = 0.0491) in the experienced and 165.5 ± 98.9 s to 66.75 ± 21.96 s (p < 0.0001) in the inexperienced surgeon group. The accuracy of the ablation process was hereby not impaired as postinterventional sectioning of the ablation zone revealed.!##!Conclusion!#!The use of a stereotactic navigation system for laparoscopic microwave ablation procedures of liver tumors significantly reduces the attempts and time of predicted correct needle placement for novices and experienced surgeons without impairing the accuracy of the ablation procedure

    True single-port cholecystectomy with ICG cholangiography through a single 15-mm trocar using the new surgical platform symphonX: first human case study with a commercially available device

    No full text
    Background Minimally invasive single-port surgery is often associated with large incisions up to 2-3 cm, complicated handling due to the lack of triangulation, and instrument crossing. Aim of this prospective study was to perform true single-port surgery (cholecystectomy) without the use of assisting trocars using a new surgical platform that allows for triangulation incorporating robotic features, and to measure the perioperative outcome and cosmetic results. Methods As the first European site after FDA and CE-mark approval, the new device has been introduced to our academic center. In patients with cholecystitis and cholecystolithiasis, the operation was performed through only one 15-mm trocar. For patients safety, intraoperative cholangiography using intravenous ICG and a standard Stryker 1588 system was routinely performed. Results Symphonx was used in n = 12 patients for abdominal surgery (6 females, mean age 42.5 [30-77], mean BMI 26.2 [19.3-38.9]. A total of 8 patients underwent surgery using no additional ports besides the 15-mm trocar; in the remaining patients, one assisting instrument (3-5 mm) was used. Mean OR time was 107 [72-221] minutes. The postoperative course was uneventful in 11 patients; in one patient, a seroma at the surgical site required interventional drainage 1 month postoperatively. No intraoperative complications occurred. Conclusion This is the first human case series using the commercially available symphonX platform for abdominal laparoscopic surgery and the first series using the system without assisting instruments. Laparoscopic cholecystectomy in patients with cholecystitis and cholecystolithiasis using the symphonX platform through only one 15-mm trocar is feasible, safe, and more cost-efficient compared to robotic platforms

    Navigated laparoscopic microwave ablation of tumour mimics in pig livers: a randomized ex-vivo experimental trial

    No full text
    Background In order to efficiently perform laparoscopic microwave ablation of liver tumours precise positioning of the ablation probe is mandatory. This study evaluates the precision and ablation accuracy using the innovative laparoscopic stereotactic navigation system CAS-One-SPOT in comparison to 2d ultrasound guided laparoscopic ablation procedures. Methods In a pig liver ablation model four surgeons, experienced (n = 2) and inexperienced (n = 2) in laparoscopic ablation procedures, were randomized for 2d ultrasound guided laparoscopic or stereotactic navigated laparoscopic ablation procedures. Each surgeon performed a total of 20 ablations. Total attempts of needle placements, time from tumor localization till beginning of ablation and ablation accuracy were analyzed. Results The use of the laparoscopic stereotactic navigation system led to a significant reduction in total attempts of needle placement. The experienced group of surgeons reduced the mean number of attempts from 2.75 +/- 2.291 in the 2d ultrasound guided ablation group to 1.45 +/- 1.191 (p = 0.0302) attempts in the stereotactic navigation group. Comparable results could be observed in the inexperienced group with a reduction of 2.5 +/- 1.50 to 1.15 +/- 0.489 (p = 0.0005). This was accompanied by a significant time saving from 101.3 +/- 112.1 s to 48.75 +/- 27.76 s (p = 0.0491) in the experienced and 165.5 +/- 98.9 s to 66.75 +/- 21.96 s (p < 0.0001) in the inexperienced surgeon group. The accuracy of the ablation process was hereby not impaired as postinterventional sectioning of the ablation zone revealed. Conclusion The use of a stereotactic navigation system for laparoscopic microwave ablation procedures of liver tumors significantly reduces the attempts and time of predicted correct needle placement for novices and experienced surgeons without impairing the accuracy of the ablation procedure
    corecore