369 research outputs found

    Export destination and the skill premium: Evidence from Chinese manufacturing industries

    Get PDF
    This paper examines the relationship between average income of export destinations and the skill premium using data of Chinese manufacturing industries from 1995 to 2008. To do so, we construct weighted average GDP per capita across destinations employing within-industry export share to each destination as weights, and then link it with industry-level wages and the skill premium. We find that industries that export more to high-income destinations tend to pay a higher skill premium, suggesting that, on average, skilled workers benefit more from high-income exports than unskilled workers. Our IV estimates confirm a causal relationship, and the results are robust to various specifications. Further results based on firm-level data show consistent evidence. Our paper highlights the role of high-income destination exports in shaping the uneven distributional effects of globalization for different types of workers

    Sampling techniques for and interpretation of milk urea nitrogen concentration

    Get PDF
    Representative MUN values can be obtained by testing a milk sample before milking, at AM or PM milking, or with an in-line siphon sampling device. MUN values obtained from homogenous milking strings are as accurate as an average MUN value obtained by sampling each cow in the string. Bulk tank sampling is not advisable because of the variation in MUN caused by stage of lactation. Small herds that feed a single TMR should use the average MUN from cows between 60 and 200 days in milk. Monthly sampling is recommended to build a database. The effect of diet changes on MUN can be assessed within 7 days

    Loss of HDAC6, a novel CHIP substrate, alleviates abnormal tau accumulation

    Get PDF
    The abnormal accumulation of the microtubule-binding protein tau is associated with a number of neurodegenerative conditions, and correlates with cognitive decline in Alzheimer's disease. The ubiquitin ligase carboxy terminus of Hsp70-interacting protein (CHIP) and the molecular chaperone Hsp90 are implicated in protein triage decisions involving tau, and have consequently been targeted for therapeutic approaches aimed at decreasing tau burden. Here, we present evidence that CHIP binds, ubiquitinates and regulates expression of histone deacetylase 6 (HDAC6). As the deacetylase for Hsp90, HDAC6 modulates Hsp90 function and determines the favorability of refolding versus degradation of Hsp90 client proteins. Moreover, we demonstrate that HDAC6 levels positively correlate with tau burden, while a decrease in HDAC6 activity or expression promotes tau clearance. Consistent with previous research on Hsp90 clients in cancer, we provide evidence that a loss of HDAC6 activity augments the efficacy of an Hsp90 inhibitor and drives client degradation, in this case tau. Therefore, our current findings not only identify HDAC6 as a critical factor for the regulation of tau levels, but also indicate that a multi-faceted treatment approach could more effectively arrest tau accumulation in disease

    Dual-source computed tomography coronary angiography: influence of obesity, calcium load, and heart rate on diagnostic accuracy

    Get PDF
    Aims To prospectively investigate the diagnostic accuracy of dual-source computed tomography coronary angiography (CTCA) to diagnose coronary stenoses in relation to body mass index (BMI), Agatston score (AS), and heart rate (HR) as compared with catheter coronary angiography (CCA). Methods and results Hundred and fifty consecutive patients (47 female, mean age 62.9 ± 12.1 years) underwent dual-source CTCA without HR control. Patients were divided into subgroups depending on the median of their BMI (26.0 kg/m2), AS (194), and HR (66 b.p.m.). CCA was considered the standard of reference. Mean BMI was 26.5 ± 4.2 kg/m2 (range 18.3-39.1 kg/m2), mean AS was 309 ± 408 (range 0-4387), and HR was 68.5 ± 12.6 b.p.m. (range 35-102 b.p.m.). Diagnostic image quality was found in 98.1% of all segments (2020/2059). Considering not-evaluative segments at CTCA as false-positive, overall per-patient sensitivity, specificity, positive, and negative predictive value were 96.6%, 86.8%, 82.6%, and 97.5%, respectively. High HR did not deteriorate diagnostic accuracy of CTCA. High BMI and AS were associated with a decrease in per-patient specificity to 84.1% and 77.8%, respectively, while sensitivity and negative predictive value remained high. Conclusion Dual-source CTCA provides high diagnostic accuracy irrespective of the HR and serves as a modality to rule-out coronary artery stenoses even in patients with high BMI and A

    Integration of Runtime Verification into Metamodeling

    Get PDF
    Domain Specific Modeling Languages (DSMLs) Modeling is a well-established practice in the development of big and complex software systems. Domain Specific Modeling Languages (DSMLs) are a technique used for specifying such systems in an abstract way. These languages define the structure, semantics and constraints for models related to the same application domain. The models created with DSMLs are then interconnected or related to one another. Among the reasons for tailoring a language to the problem space is their better understandability by domain experts, capacity for high-level abstraction, and user friendliness. However, the use of DSMLs (like the use of types in general) does not shield the produced software from bugs or man-made mistakes. Software failures may still occur on complex systems due to a variety of reasons such as design errors, hardware breakdown or network problems. Ruling out these failures requires that verification methods that guarantee correct execution even in corner cases are integrated into the development process. We previously presented our ideas for integrating specifications tighter with the mode

    Sirolimus and kidney growth in autosomal dominant polycystic kidney disease

    Full text link
    BACKGROUND: In autosomal dominant polycystic kidney disease (ADPKD), aberrant activation of the mammalian target of rapamycin (mTOR) pathway is associated with progressive kidney enlargement. The drug sirolimus suppresses mTOR signaling. METHODS: In this 18-month, open-label, randomized, controlled trial, we sought to determine whether sirolimus halts the growth in kidney volume among patients with ADPKD. We randomly assigned 100 patients between the ages of 18 and 40 years to receive either sirolimus (target dose, 2 mg daily) or standard care. All patients had an estimated creatinine clearance of at least 70 ml per minute. Serial magnetic resonance imaging was performed to measure the volume of polycystic kidneys. The primary outcome was total kidney volume at 18 months on blinded assessment. Secondary outcomes were the glomerular filtration rate and urinary albumin excretion rate at 18 months. RESULTS: At randomization, the median total kidney volume was 907 cm(3) (interquartile range, 577 to 1330) in the sirolimus group and 1003 cm(3) (interquartile range, 574 to 1422) in the control group. The median increase over the 18-month period was 99 cm(3) (interquartile range, 43 to 173) in the sirolimus group and 97 cm(3) (interquartile range, 37 to 181) in the control group. At 18 months, the median total kidney volume in the sirolimus group was 102% of that in the control group (95% confidence interval, 99 to 105; P=0.26). The glomerular filtration rate did not differ significantly between the two groups; however, the urinary albumin excretion rate was higher in the sirolimus group. CONCLUSIONS: In adults with ADPKD and early chronic kidney disease, 18 months of treatment with sirolimus did not halt polycystic kidney growth. (ClinicalTrials.gov number, NCT00346918.

    Dual-source CT for chest pain assessment

    Get PDF
    Comprehensive CT angiography protocols offering a simultaneous evaluation of pulmonary embolism, coronary stenoses and aortic disease are gaining attractiveness with recent CT technology. The aim of this study was to assess the diagnostic accuracy of a specific dual-source CT protocol for chest pain assessment. One hundred nine patients suffering from acute chest pain were examined on a dual-source CT scanner with ECG gating at a temporal resolution of 83 ms using a body-weight-adapted contrast material injection regimen. The images were evaluated for the cause of chest pain, and the coronary findings were correlated to invasive coronary angiography in 29 patients (27%). The files of patients with negative CT examinations were reviewed for further diagnoses. Technical limitations were insufficient contrast opacification in six and artifacts from respiration in three patients. The most frequent diagnoses were coronary stenoses, valvular and myocardial disease, pulmonary embolism, aortic aneurysm and dissection. Overall sensitivity for the identification of the cause of chest pain was 98%. Correlation to invasive coronary angiography showed 100% sensitivity and negative predictive value for coronary stenoses. Dual-source CT offers a comprehensive, robust and fast chest pain assessment

    Diagnostic accuracy of computed tomography coronary angiography in patients with a zero calcium score

    Get PDF
    To evaluate the diagnostic accuracy of 64-slice CT coronary angiography (CT-CA) for the detection of significant coronary artery stenosis in patients with zero on the Agatston Calcium Score (CACS). We enrolled 279 consecutive patients (96 male, mean age 48±12 years) with suspected coronary artery disease. Patients were symptomatic (n=208) or asymptomatic (n=71), and underwent conventional coronary angiography (CAG). For CT-CA we administered an IV bolus of 100 ml of iodinated contrast material. CT-CA was compared to CAG using a threshold for significant stenosis of ≤50%. The prevalence of disease demonstrated at CAG was 15% (1.4% in asymptomatic). The population at CAG showed no or non-significant disease in 85% (238/279), single vessel disease in 9% (25/279), and multi-vessel disease in 6% (16/279). Sensitivity, specificity, and positive and negative predictive values of CT-CA vs. CAG on the patient level were 100%, 95%, 76%, and 100% in the overall population and 100%, 100%, 100%, and 100% in asymptomatic patients, respectively. CT-CA proves high diagnostic performance in patients with or without symptoms and with zero CACS. The prevalence of significant disease detected by CT-CA was not negligible in asymptomatic patients. The role of CT-CA in asymptomatic patients remains uncertain
    corecore