9 research outputs found

    322. Evaluation of the BioFire® Bone and Joint Infection (BJI) Panel for the Detection of Microorganisms and Antimicrobial Resistance Genes in Synovial Fluid Specimens

    Get PDF
    Background Bone and Joint Infections (BJIs) present with non-specific symptoms that may include pain, swelling, and fever and are associated with high morbidity and significant risk of mortality. BJIs can be caused by a variety of bacteria and fungi, including anaerobes and microorganisms that can be challenging to culture or identify by traditional microbiological methods. Clinicians primarily rely on culture to identify the pathogen(s) responsible for infection. The BioFire® Bone and Joint Infection (BJI) Panel (BioFire Diagnostics, Salt Lake City, UT) is designed to detect 15 gram-positive bacteria (including seven anaerobes), 14 gram-negative bacteria (including one anaerobe), two yeast, and eight antimicrobial resistance (AMR) genes from synovial fluid specimens in about an hour. The objective of this study was to evaluate the performance of an Investigational Use Only (IUO) version of the BioFire BJI Panel compared to various reference methods. Methods Remnant synovial fluid specimens, which were collected for routine clinical care at 13 study sites in the US and Europe, underwent testing using an IUO version of the BioFire BJI Panel. Performance of this test was determined by comparison to Standard of Care (SoC) consisting of bacterial culture performed at each study site according to their routine procedures. Results A total of 1544 synovial fluid specimens were collected and tested with the BioFire BJI Panel. The majority of specimens were from knee joints (77.9%) and arthrocentesis (79.4%) was the most common collection method. Compared to SoC culture, overall sensitivity was 90.2% and specificity was 99.8%. The BioFire BJI Panel yielded a total of 268 Detected results, whereas SoC yielded a total of 215 positive results for on-panel analytes. Conclusion The BioFire BJI Panel is a sensitive, specific, and robust test for rapid detection of a wide range of analytes in synovial fluid specimens. The number of microorganisms and resistance genes included in the BioFire BJI Panel, together with a reduced time-to-result and increased diagnostic yield compared to culture, is expected to aid in the timely diagnosis and appropriate management of BJIs

    Multicenter Evaluation of BioFire FilmArray Meningitis/Encephalitis Panel for Detection of Bacteria, Viruses, and Yeast in Cerebrospinal Fluid Specimens.

    No full text
    Rapid diagnosis and treatment of infectious meningitis and encephalitis are critical to minimize morbidity and mortality. Comprehensive testing of cerebrospinal fluid (CSF) often includes Gram stain, culture, antigen detection, and molecular methods, paired with chemical and cellular analyses. These methods may lack sensitivity or specificity, can take several days, and require significant volume for complete analysis. The FilmArray Meningitis/Encephalitis (ME) Panel is a multiplexed in vitro diagnostic test for the simultaneous, rapid (∼1-h) detection of 14 pathogens directly from CSF specimens: Escherichia coli K1, Haemophilus influenzae, Listeria monocytogenes, Neisseria meningitidis, Streptococcus pneumoniae, Streptococcus agalactiae, cytomegalovirus, enterovirus, herpes simplex virus 1 and 2, human herpesvirus 6, human parechovirus, varicella-zoster virus, and Cryptococcus neoformans/Cryptococcus gattii We describe a multicenter evaluation of 1,560 prospectively collected CSF specimens with performance compared to culture (bacterial analytes) and PCR (all other analytes). The FilmArray ME Panel demonstrated a sensitivity or positive percentage of agreement of 100% for 9 of 14 analytes. Enterovirus and human herpesvirus type 6 had agreements of 95.7% and 85.7%, and L. monocytogenes and N. meningitidis were not observed in the study. For S. agalactiae, there was a single false-positive and false-negative result each, for a sensitivity and specificity of 0 and 99.9%, respectively. The specificity or negative percentage of agreement was 99.2% or greater for all other analytes. The FilmArray ME Panel is a sensitive and specific test to aid in diagnosis of ME. With use of this comprehensive and rapid test, improved patient outcomes and antimicrobial stewardship are anticipated

    Practical Comparison of the BioFire FilmArray Pneumonia Panel to Routine Diagnostic Methods and Potential Impact on Antimicrobial Stewardship in Adult Hospitalized Patients with Lower Respiratory Tract Infections.

    No full text
    Lower respiratory tract infections, including hospital-acquired and ventilator-associated pneumonia, are common in hospitalized patient populations. Standard methods frequently fail to identify the infectious etiology due to the polymicrobial nature of respiratory specimens and the necessity of ordering specific tests to identify viral agents. The potential severity of these infections combined with a failure to clearly identify the causative pathogen results in administration of empirical antibiotic agents based on clinical presentation and other risk factors. We examined the impact of the multiplexed, semiquantitative BioFire FilmArray Pneumonia panel (PN panel) test on laboratory reporting for 259 adult inpatients submitting bronchoalveolar lavage (BAL) specimens for laboratory analysis. The PN panel demonstrated a combined 96.2% positive percent agreement (PPA) and 98.1% negative percent agreement (NPA) for the qualitative identification of 15 bacterial targets compared to routine bacterial culture. Semiquantitative values reported by the PN panel were frequently higher than values reported by culture, resulting in semiquantitative agreement (within the same lo

    Multicenter Evaluation of the BioFire FilmArray Pneumonia/Pneumonia Plus Panel for Detection and Quantification of Agents of Lower Respiratory Tract Infection.

    No full text
    The ability to provide timely identification of the causative agents of lower respiratory tract infections can promote better patient outcomes and support antimicrobial stewardship efforts. Current diagnostic testing options include culture, molecular testing, and antigen detection. These methods may require collection of various specimens, involve extensive sample treatment, and can suffer from low sensitivity and long turnaround times. This study assessed the performance of the BioFire FilmArray Pneumonia Panel (PN panel) and Pneumonia Plus Panel (PNplus panel), an FDA-cleared sample-to-answer assay that enables the detection of viruses, atypical bacteria, bacteria, and antimicrobial resistance marker genes from lower respiratory tract specimens (sputum and bronchoalveolar lavage [BAL] fluid). Semiquantitative results are also provided for the bacterial targets. This paper describes selected analytical and clinical studies that were conducted to evaluate performance of the panel for regulatory clearance. Prospectively collected respiratory specimens (846 BAL and 836 sputum specimens) evaluated with the PN panel were also tested by quantitative reference culture and molecular methods for comparison. The PN panel showed a sensitivity of 100% for 15/22 etiologic targets using BAL specimens and for 10/24 using sputum specimens. All other targets had sensitivities of ≥75% or were unable to be calculated due to low prevalence in the study population. Specificity for all targets was ≥87.2%, with many false-positive results compared to culture that were confirmed by alternative molecular methods. Appropriate adoption of this test could provide actionable diagnostic information that is anticipated to impact patient care and antimicrobial stewardship decisions

    Diabetes and risk of pancreatic cancer: a pooled analysis from the pancreatic cancer cohort consortium

    No full text
    PURPOSE: Diabetes is a suspected risk factor for pancreatic cancer, but questions remain about whether it is a risk factor or a result of the disease. This study prospectively examined the association between diabetes and the risk of pancreatic adenocarcinoma in pooled data from the NCI pancreatic cancer cohort consortium (PanScan). METHODS: The pooled data included 1,621 pancreatic adenocarcinoma cases and 1,719 matched controls from twelve cohorts using a nested case-control study design. Subjects who were diagnosed with diabetes near the time (<2 years) of pancreatic cancer diagnosis were excluded from all analyses. All analyses were adjusted for age, race, gender, study, alcohol use, smoking, BMI, and family history of pancreatic cancer. RESULTS: Self-reported diabetes was associated with a forty percent increased risk of pancreatic cancer (OR = 1.40, 95 % CI: 1.07, 1.84). The association differed by duration of diabetes; risk was highest for those with a duration of 2-8 years (OR = 1.79, 95 % CI: 1.25, 2.55); there was no association for those with 9+ years of diabetes (OR = 1.02, 95 % CI: 0.68, 1.52). CONCLUSIONS: These findings provide support for a relationship between diabetes and pancreatic cancer risk. The absence of association in those with the longest duration of diabetes may reflect hypoinsulinemia and warrants further investigation

    Progression of Geographic Atrophy in Age-related Macular Degeneration

    No full text
    corecore