11,640 research outputs found

    Support varieties for selfinjective algebras

    Full text link
    Support varieties for any finite dimensional algebra over a field were introduced by Snashall-Solberg using graded subalgebras of the Hochschild cohomology. We mainly study these varieties for selfinjective algebras under appropriate finite generation hypotheses. Then many of the standard results from the theory of support varieties for finite groups generalize to this situation. In particular, the complexity of the module equals the dimension of its corresponding variety, all closed homogeneous varieties occur as the variety of some module, the variety of an indecomposable module is connected, periodic modules are lines and for symmetric algebras a generalization of Webb's theorem is true

    Collective motion of active Brownian particles in one dimension

    Full text link
    We analyze a model of active Brownian particles with non-linear friction and velocity coupling in one spatial dimension. The model exhibits two modes of motion observed in biological swarms: A disordered phase with vanishing mean velocity and an ordered phase with finite mean velocity. Starting from the microscopic Langevin equations, we derive mean-field equations of the collective dynamics. We identify the fixed points of the mean-field equations corresponding to the two modes and analyze their stability with respect to the model parameters. Finally, we compare our analytical findings with numerical simulations of the microscopic model.Comment: submitted to Eur. Phys J. Special Topic

    Radiation hardness of CMS pixel barrel modules

    Get PDF
    Pixel detectors are used in the innermost part of the multi purpose experiments at LHC and are therefore exposed to the highest fluences of ionising radiation, which in this part of the detectors consists mainly of charged pions. The radiation hardness of all detector components has thoroughly been tested up to the fluences expected at the LHC. In case of an LHC upgrade, the fluence will be much higher and it is not yet clear how long the present pixel modules will stay operative in such a harsh environment. The aim of this study was to establish such a limit as a benchmark for other possible detector concepts considered for the upgrade. As the sensors and the readout chip are the parts most sensitive to radiation damage, samples consisting of a small pixel sensor bump-bonded to a CMS-readout chip (PSI46V2.1) have been irradiated with positive 200 MeV pions at PSI up to 6E14 Neq and with 21 GeV protons at CERN up to 5E15 Neq. After irradiation the response of the system to beta particles from a Sr-90 source was measured to characterise the charge collection efficiency of the sensor. Radiation induced changes in the readout chip were also measured. The results show that the present pixel modules can be expected to be still operational after a fluence of 2.8E15 Neq. Samples irradiated up to 5E15 Neq still see the beta particles. However, further tests are needed to confirm whether a stable operation with high particle detection efficiency is possible after such a high fluence.Comment: Contribution to the 11th European Symposium on Semiconductor Detectors June 7-11, 2009 Wildbad Kreuth, German

    Requirement for beta-catenin in anterior-posterior axis formation in mice

    Get PDF
    The anterior-posterior axis of the mouse embryo is defined before formation of the primitive streak, and axis specification and subsequent anterior development involves signaling from both embryonic ectoderm and visceral endoderm. Tauhe Wnt signaling pathway is essential for various developmental processes, but a role in anterior-posterior axis formation in the mouse has not been previously established. Beta-catenin is a central player in the Wnt pathway and in cadherin-mediated cell adhesion. We generated beta-catenin-deficient mouse embryos and observed a defect in anterior-posterior axis formation at embryonic day 5.5, as visualized by the absence of Hex and Hesx1 and the mislocation of cerberus-like and Lim1 expression. Subsequently, no mesoderm and head structures are generated. Intercellular adhesion is maintained since plakoglobin substitutes for beta-catenin. Our data demonstrate that beta-catenin function is essential in anterior-posterior axis formation in the mouse, and experiments with chimeric embryos show that this function is required..

    An operational measure of physician lifelong learning: its development, components and preliminary psychometric data

    Get PDF
    Despite the emphasis placed on physicians’ lifelong learning, no psychometrically sound instrument has been developed to provide an operational measure of the concept and its components among physicians. The authors designed this study to develop a tool for measuring physician lifelong learning, to identify its underlying components and to assess its psychometric properties. A 37-item questionnaire was developed, based on a review of literature and the results of two pilot studies. Psychometric analyses of the responses of 160 physicians identified 19 items that were included in the Jefferson Scale of Physician Lifelong Learning. Factor analysis of the 19 items showed five meaningful factors that were consistent with the definition and major features of lifelong learning. They were ‘need recognition’, ‘research endeavor’, ‘self-initiation’, ‘technical skills’ and ‘personal motivation’. The method of contrasted groups provided evidence in support of the validity of the five factors. The factors’ reliability was assessed by coefficient alpha. It is concluded that lifelong learning is a multifaceted concept, and its operational measure is feasible for evaluating different educational programs and for studying group differences among physicians

    Dithienosilole-based all-conjugated block copolymers synthesized by a combination of quasiliving Kumada and Negishi catalyst-transfer polycondensations

    Get PDF
    Herein, we present a quasi-living Negishi-type catalyst-transfer polycondensation of a zinc–organic DTSbased monomer which provides an access to narrowly distributed poly(4,4-bis(2-ethylhexyl)dithieno[3,2-b:20,30-d]silole (PDTS) with controlled molecular weight. The synthesis of well-defined all-conjugated diblock copolymers containing a PDTS block was accomplished by a combination of Kumada and Negishi catalyst-transfer polycondensations (KCTP and NCTP, respectively). Particularly, it was shown that living P3HT chains obtained by KCTP of magnesium–organic thiophene-based monomer efficiently initiate NCTP of zinc–organic DTS-based monomer. The purity of the DTS-based monomer was found to be a crucial factor for achieving a clean chain-growth polymerization process. A combination of physico-chemical methods was used to prove the success of the block copolymerization

    Advanced cryo-tomography workflow developments - correlative microscopy, milling automation and cryo-lift-out

    No full text
    Cryo-electron tomography (cryo-ET) is a groundbreaking technology for 3D visualisation and analysis of biomolecules in the context of cellular structures. It allows structural investigations of single proteins as well as their spatial arrangements within the cell. Cryo-tomograms provide a snapshot of the complex, heterogeneous and transient subcellular environment. Due to the excellent structure preservation in amorphous ice, it is possible to study interactions and spatial relationships of proteins in their native state without interference caused by chemical fixatives or contrasting agents. With the introduction of focused ion beam (FIB) technology, the preparation of cellular samples for electron tomography has become much easier and faster. The latest generation of integrated FIB and scanning electron microscopy (SEM) instruments (dual beam microscopes), specifically designed for cryo-applications, provides advances in automation, imaging and the preparation of high-pressure frozen bulk samples using cryo-lift-out technology. In addition, correlative cryo-fluorescence microscopy provides cellular targeting information through integrated software and hardware interfaces. The rapid advances, based on the combination of correlative cryo-microscopy, cryo-FIB and cryo-ET, have already led to a wealth of new insights into cellular processes and provided new 3D image data of the cell. Here we introduce our recent developments within the cryo-tomography workflow, and we discuss the challenges that lie ahead. Lay Description This article describes our recent developments for the cryo-electron tomography (cryo-ET) workflow. Cryo-ET offers superior structural preservation and provides 3D snapshots of the interior of vitrified cells at molecular resolution. Before a cellular sample can be imaged by cryo-ET, it must be made accessible for transmission electron microscopy. This is achieved by preparing a 200-300 nm thin cryo-lamella from the cellular sample using a cryo-focused ion beam (cryo-FIB) microscope. Cryo-correlative light and electron microscopy (cryo-CLEM) is used within the workflow to guide the cryo-lamella preparation to the cellular areas of interest. We cover a basic introduction of the cryo-ET workflow and show new developments for cryo-CLEM, which facilitate the connection between the cryo-light microscope and the cryo-FIB. Next, we present our progress in cryo-FIB software automation to streamline cryo-lamella preparation. In the final section we demonstrate how the cryo-FIB can be used for 3D imaging and how bulk-frozen cellular samples (obtained by high-pressure freezing) can be processed using the newly developed cryo-lift-out technology
    • …
    corecore