580 research outputs found
Mapping the Evolution of Optically-Generated Rotational Wavepackets in a Room Temperature Ensemble of D
A coherent superposition of rotational states in D has been excited by
nonresonant ultrafast (12 femtosecond) intense (2 10
Wcm) 800 nm laser pulses leading to impulsive dynamic alignment.
Field-free evolution of this rotational wavepacket has been mapped to high
temporal resolution by a time-delayed pulse, initiating rapid double
ionization, which is highly sensitive to the angle of orientation of the
molecular axis with respect to the polarization direction, . The
detailed fractional revivals of the neutral D wavepacket as a function of
and evolution time have been observed and modelled theoretically.Comment: 4 pages, 3 figures. Accepted for publication in Phys. Rev. A. Full
reference to follow.
Recommended from our members
Power spectral density specifications for high-power laser systems
This paper describes the use of Fourier techniques to characterize the transmitted and reflected wavefront of optical components. Specifically, a power spectral density, (PSD), approach is used. High power solid-state lasers exhibit non-linear amplification of specific spatial frequencies. Thus, specifications that limit the amplitude of these spatial frequencies are necessary in the design of these systems. Further, NIF optical components have square, rectangular or irregularly shaped apertures with major dimensions up-to 800 mm. Components with non-circular apertures can not be analyzed correctly with Zernicke polynomials since these functions are an orthogonal set for circular apertures only. A more complete and powerful representation of the optical wavefront can be obtained by Fourier analysis in 1 or 2 dimensions. The PSD is obtained from the amplitude of frequency components present in the Fourier spectrum. The shape of a resultant wavefront or the focal spot of a complex multicomponent laser system can be calculated and optimized using PSDs of the individual optical components which comprise the system. Surface roughness can be calculated over a range of spatial scale-lengths by integrating the PSD. Finally, since the optical transfer function (OTF) of the instruments used to measure the wavefront degrades at high spatial frequencies, the PSD of an optical component is underestimated. We can correct for this error by modifying the PSD function to restore high spatial frequency information. The strengths of PSD analysis are leading us to develop optical specifications incorporating this function for the planned National Ignition Facility (NIF)
Recommended from our members
The use of an intermediate wavelength laser for alignment to inertial confinement fusion targets
The conceptual design of the National Ignition Facility (NIF) 192 beam laser incorporates a low-power alignment beam injected in the pinhole plane of the final spatial filter with a wave length intermediate between the 1053 mn laser output and the 351 mn frequency-converted beam that illuminates the target Choosing the specific wavelength for which the spatial filter plane is reimaged in the same target chamber plane as the frequency-converted main laser pulse, achieves optimum accuracy without the need for additional means to insure precise overlap between the two beams. Insertion of the alignment beam after the last laser amplifier also allows alignment to the target while the amplifiers are still cooling from a previous shot
Advanced power sources for space missions
Approaches to satisfying the power requirements of space-based Strategic Defense Initiative (SDI) missions are studied. The power requirements for non-SDI military space missions and for civil space missions of the National Aeronautics and Space Administration (NASA) are also considered. The more demanding SDI power requirements appear to encompass many, if not all, of the power requirements for those missions. Study results indicate that practical fulfillment of SDI requirements will necessitate substantial advances in the state of the art of power technology. SDI goals include the capability to operate space-based beam weapons, sometimes referred to as directed-energy weapons. Such weapons pose unprecedented power requirements, both during preparation for battle and during battle conditions. The power regimes for these two sets of applications are referred to as alert mode and burst mode, respectively. Alert-mode power requirements are presently stated to range from about 100 kW to a few megawatts for cumulative durations of about a year or more. Burst-mode power requirements are roughly estimated to range from tens to hundreds of megawatts for durations of a few hundred to a few thousand seconds. There are two likely energy sources, chemical and nuclear, for powering SDI directed-energy weapons during the alert and burst modes. The choice between chemical and nuclear space power systems depends in large part on the total duration during which power must be provided. Complete study findings, conclusions, and eight recommendations are reported
Evaluation of marking of peer marking in oral presentation.
BACKGROUND: Peer marking is an important skill for students, helping them to understand the process of learning and assessment. This method is increasingly used in medical education, particularly in formative assessment. However, the use of peer marking in summative assessment is not widely adopted because many teachers are concerned about biased marking by students of their peers. OBJECTIVE: The aim of this study was to investigate whether marking of summative peer assessment can improve the reliability of peer marking. METHODS: In a retrospective analysis, the peer-marking results of a summative assessment of oral presentations of two cohorts of students were compared. One group of students was told that their peer marks would be assessed against a benchmark consisting of the average of examiner marks and that these scores together with the peer and examiner marks would form their final exam results. The other group of students were just informed that their final exam results would be determined based on the examiner and peer marks. RESULTS: Based on examiner marks, both groups of students performed similarly in their summative assessment, agreement between student markers was less consistent and more polar than the examiners. When compared with the examiners, students who were told that their peer marking would be scored were more generous markers (their average peer mark was 2.4 % points higher than the average examiner mark) while students who were not being scored on their marking were rather harsh markers (their average peer mark was 4.2 % points lower than the average examiner mark), with scoring of the top-performing students most affected. CONCLUSIONS: Marking of peer marking had a small effect on the marking conduct of students in summative assessment of oral presentation but possibly indicated a more balanced marking performance
Recommended from our members
Specification of optical components using the power spectral density function
This paper describes the use of Fourier techniques to characterize the wavefront of optical components, specifically, the use of the power spectral density, (PSD), function. The PSDs of several precision optical components will be shown. Many of the optical components of interest to us have square, rectangular or irregularly shaped apertures with major dimensions up-to 800 mm. The wavefronts of components with non-circular apertures cannot be analyzed with Zernicke polynomials since these functions are an orthogonal set for circular apertures only. Furthermore, Zernicke analysis is limited to treating low frequency wavefront aberrations; mid-spatial scale and high frequency error are expressed only as ``residuals.`` A more complete and powerful representation of the optical wavefront can be obtained by Fourier analysis in 1 or 2 dimensions. The PSD is obtained from the amplitude of frequency components present in the Fourier spectrum. The PSD corresponds to the scattered intensity as a function of scattering angle in the wavefront and can be used to describe the intensity distribution at focus. The shape of a resultant wavefront or the focal spot of a complex multi-component laser system can be calculated and optimized using the PSDs of individual optical components which comprise it
Development of paediatric quality of inpatient care indicators for low-income countries - A Delphi study
BACKGROUND: Indicators of quality of care for children in hospitals in low-income countries have been proposed, but information on their perceived validity and acceptability is lacking. METHODS: Potential indicators representing structural and process aspects of care for six common conditions were selected from existing, largely qualitative WHO assessment tools and guidelines. We employed the Delphi technique, which combines expert opinion and existing scientific information, to assess their perceived validity and acceptability. Panels of experts, one representing an international panel and one a national (Kenyan) panel, were asked to rate the indicators over 3 rounds and 2 rounds respectively according to a variety of attributes. RESULTS: Based on a pre-specified consensus criteria most of the indicators presented to the experts were accepted: 112/137(82%) and 94/133(71%) for the international and local panels respectively. For the other indicators there was no consensus; none were rejected. Most indicators were rated highly on link to outcomes, reliability, relevance, actionability and priority but rated more poorly on feasibility of data collection under routine conditions. There was moderate to substantial agreement between the two panels of experts. CONCLUSIONS: This Delphi study provided evidence for the perceived usefulness of most of a set of measures of quality of hospital care for children proposed for use in low-income countries. However, both international and local experts expressed concerns that data for many process-based indicators may not currently be available. The feasibility of widespread quality assessment and responsiveness of indicators to intervention should be examined as part of continued efforts to improve approaches to informative hospital quality assessment
Genetic diversity of Brazilian isolates of feline immunodeficiency virus
We isolated Feline immunodeficiency virus (FIV) from three adult domestic cats, originating from two open shelters in Brazil. Viruses were isolated from PBMC following co-cultivation with the feline T-lymphoblastoid cell line MYA-1. All amplified env gene products were cloned directly into pGL8MYA. The nucleic acid sequences of seven clones were determined and then compared with those of previously described isolates. The sequences of all of the Brazilian virus clones were distinct and phylogenetic analysis revealed that all belong to subtype B. Three variants isolated from one cat and two variants were isolated from each of the two other cats, indicating that intrahost diversity has the potential to pose problems for the treatment and diagnosis of FIV infection
- …