339 research outputs found

    Orchestrators of coordination:Towards a new role of the state in coordinated capitalism?

    Get PDF
    Liberalization poses significant challenges for the continued provision of collective goods within coordinated market economies (CME). Extant scholarship suggests two dominant sets of responses. Either CMEs continue to rely on employer coordination, but only for a privileged core, leading to dualization. Or, in cases where the state enjoys high capacity, the state instead compensates for liberalization but ends up crowding out employer coordination. In both cases, the result is decreasing employer coordination. We argue that in CMEs, the state may also play the role of “orchestrator” by supporting the revitalization of employer coordination. It does so through the deployment of ideational and institutional resources that mobilize employers’ associations on a voluntary basis. Applying our framework to a core area of coordinated capitalism, vocational education and training, we show that in both Germany and Switzerland, this indirect and soft form of state intervention was instrumental for turning around their crisis-stricken vocational training systems.publishe

    Versatile multipass cell for laser spectroscopic trace gas analysis

    Get PDF
    The design, construction and characterization of a novel circular multipass cell for sensitive trace gas analysis are presented. This cell allows for easy modification of the optical path length without any changes of its physical parameters. Furthermore, it is suited for three different detection techniques: direct absorption, wavelength modulation and photoacoustics. To demonstrate its performance, mixing ratios of 13CO2 and N2O were measured from ambient air, using a quantum cascade laser. With the direct absorption method, noise equivalent 1-s precisions of 2.7ppb and 0.2ppb are achieved for 13CO2 and N2O, respectively. The wavelength modulation technique resulted in 4.3ppb precision with 1-s averaging for the 13CO2 measurements. AQ-factor of 190 and a normalized noise equivalent minimum absorption of 1.3×10−8cm−1 W Hz−1/2 are achieved using the photoacoustic techniqu

    Continuous isotopic composition measurements of tropospheric CO<sub>2</sub> at Jungfraujoch (3580 m a.s.l.), Switzerland: real-time observation of regional pollution events

    Get PDF
    A quantum cascade laser based absorption spectrometer (QCLAS) is applied for the first time to perform in situ, continuous and high precision isotope ratio measurements of CO<sub>2</sub> in the free troposphere. Time series of the three main CO<sub>2</sub> isotopologue mixing ratios (<sup>12</sup>C<sup>16</sup>CO<sub>2</sub>, <sup>13</sup>C<sup>16</sup>CO<sub>2</sub> and <sup>12</sup>C<sup>18</sup>O<sup>16</sup>O) have simultaneously been measured at one second time resolution over two years (from August 2008 to present) at the High Altitude Research Station Jungfraujoch (3580 m a.s.l., Switzerland). This work focuses on periods in February 2009 only, when sudden and pronounced enhancements in the tropospheric CO<sub>2</sub> were observed. These short-term changes were closely correlated with variations in CO mixing ratios measured at the same site, indicating combustion related emissions as potential source. The analytical precision of 0.046&permil; (at 50 s integration time) for both &delta;<sup>13</sup>C and &delta;<sup>18</sup>O and the high temporal resolution allowed the application of the Keeling plot method for source signature identification. The spatial origin of these CO<sub>2</sub> emission sources was then determined by backward Lagrangian particle dispersion simulations

    Tackling the Root Cause of Surface-Induced Coagulation: Inhibition of FXII Activation to Mitigate Coagulation Propagation and Prevent Clotting

    Get PDF
    Factor XII (FXII) is a zymogen present in blood that tends to adsorb onto the surfaces of blood-contacting medical devices. Once adsorbed, it becomes activated, initiating a cascade of enzymatic reactions that lead to surface-induced coagulation. This process is characterized by multiple redundancies, making it extremely challenging to prevent clot formation and preserve the properties of the surface. In this study, a novel modulatory coating system based on C1-esterase inhibitor (C1INH) functionalized polymer brushes, which effectively regulates the activation of FXII is proposed. Using surface plasmon resonance it is demonstrated that this coating system effectively repels blood plasma proteins, including FXII, while exhibiting high activity against activated FXII and plasma kallikrein under physiological conditions. This unique property enables the modulation of FXII activation without interfering with the overall hemostasis process. Furthermore, through dynamic Chandler loop studies, it is shown that this coating significantly improves the hemocompatibility of polymeric surfaces commonly used in medical devices. By addressing the root cause of contact activation, the synergistic interplay between the antifouling polymer brushes and the modulatory C1INH is expected to lay the foundation to enhance the hemocompatibility of medical device surfaces.© 2023 The Authors. Macromolecular Bioscience published by Wiley-VCH GmbH

    High precision and continuous field measurements of δ 13C and δ 18O in carbon dioxide with a cryogen-free QCLAS

    Get PDF
    The present paper describes a compact and cryogen-free, quantum cascade laser based absorption spectrometer (QCLAS) designed for in situ, continuous and high precision isotope ratio measurements of atmospheric CO2. The mobile instrument incorporates several new features including a novel astigmatic multi-pass cell assembly, a quasi-room temperature quantum cascade laser, thermoelectrically cooled detectors as well as a new retrieval approach. The combination of these features now makes it possible to measure isotope ratios of ambient CO2 with a precision of 0.03 and 0.05‰ for δ13C and δ18O, respectively, using a 100s integration time. A robust and optimized calibration procedure was developed to bring the retrieved isotope ratios on an absolute scale. This assures an accuracy better than 0.1‰ under laboratory conditions. The instrument performance was also assessed in a field campaign in which the spectrometer operated autonomously and provided mixing ratio values for the main three CO2 isotopologues at one second time resolution. An accuracy of 0.2‰ was routinely obtained for both isotope ratios during the entire period. The results were in excellent agreement with the standard laboratory-based isotope ratio mass spectrometer measurements made on field-collected flask samples. A few illustrative examples are used to depict the potential of this optical method in atmosphere-biosphere researc

    Towards Business-to-IT Alignment in the Cloud

    Get PDF
    Cloud computing offers a great opportunity for business process (BP) flexibility, adaptability and reduced costs. This leads to realising the notion of business process as a service (BPaaS), i.e., BPs offered on-demand in the cloud. This paper introduces a novel architecture focusing on BPaaS design that includes the integration of existing state-of-the-art components as well as new ones which take the form of a business and a syntactic matchmaker. The end result is an environment enabling to transform domain-specific BPs into executable workflows which can then be made deployable in the cloud so as to become real BPaaSes

    Assessment of recent advances in measurement techniques for atmospheric carbon dioxide and methane observations

    Get PDF
    This is the final version. Available from European Geosciences Union via the DOI in this record. Until recently, atmospheric carbon dioxide (CO2) and methane (CH4) measurements were made almost exclusively using nondispersive infrared (NDIR) absorption and gas chromatography with flame ionisation detection (GC/FID) techniques, respectively. Recently, commercially available instruments based on spectroscopic techniques such as cavity ring-down spectroscopy (CRDS), off-axis integrated cavity output spectroscopy (OA-ICOS) and Fourier transform infrared (FTIR) spectroscopy have become more widely available and affordable. This resulted in a widespread use of these techniques at many measurement stations. This paper is focused on the comparison between a CRDS "travelling instrument" that has been used during performance audits within the Global Atmosphere Watch (GAW) programme of the World Meteorological Organization (WMO) with instruments incorporating other, more traditional techniques for measuring CO2 and CH4 (NDIR and GC/FID). We demonstrate that CRDS instruments and likely other spectroscopic techniques are suitable for WMO/GAW stations and allow a smooth continuation of historic CO2 and CH4 time series. Moreover, the analysis of the audit results indicates that the spectroscopic techniques have a number of advantages over the traditional methods which will lead to the improved accuracy of atmospheric CO2 and CH4 measurements

    Breath acetone as a marker of energy balance: an exploratory study in healthy humans.

    Get PDF
    An exploratory study was performed on eight healthy volunteers to assess how short-term changes in energy balance and dietary carbohydrate content impact breath acetone concentrations. Participants were studied on three occasions: on each occasion, they remained fasted and in resting conditions during the first 2 h to assess basal breath acetone and blood beta-hydroxybutyrate (BOHB). During the next 6 h, they remained fasted on one occasion (F), or were fed hourly high carbohydrate (HC) or low-carbohydrate (LC) meals to induce a positive energy balance on the other two occasions. They remained in resting conditions during 4 h, then performed a 2-hour low intensity exercise (25 W) inducing a negative energy balance. In resting conditions, breath acetone and blood BOHB concentrations increased progressively compared to basal values in F, but decreased and remained low throughout the test in HC. With LC, breath acetone increased progressively, while blood BOHB decreased. This exploratory study indicates that breath acetone reliably detects a stimulation of ketogenesis during a short-term fast. It also suggests that LC and HC differentially impact BOHB and acetone production and utilization, and reveals possible limitations to the use of breath acetone as a marker of energy balance

    The Design of the n2EDM Experiment

    Get PDF
    We present the design of a next-generation experiment, n2EDM, currently under construction at the ultracold neutron source at the Paul Scherrer Institute (PSI) with the aim of carrying out a high-precision search for an electric dipole moment of the neutron. The project builds on experience gained with the previous apparatus operated at PSI until 2017, and is expected to deliver an order of magnitude better sensitivity with provision for further substantial improvements. An overview is of the experimental method and setup is given, the sensitivity requirements for the apparatus are derived, and its technical design is described
    corecore