37 research outputs found

    Spectral analysis of the blood flow in the foot microvascular bed during thermal testing in patients with diabetes mellitus

    Get PDF
    Timely diagnostics of microcirculatory system abnormalities, which are the most severe diabetic complications, is one of the major problems facing modern health care. Functional abnormalities manifest themselves earlier than the structural ones, and therefore their assessment is the issue of primary importance. In this study Laser Doppler flowmetry, a noninvasive technique for the cutaneous blood flow monitoring, was utilized together with local temperature tests and wavelet analysis. The study of the blood flow in the microvascular bed of toes was carried out in the control group of 40 healthy subjects and in two groups of 17 type 1 and 23 type 2 diabetic patients. The local temperature tests demonstrated that the diabetic patients have impaired vasodilation in response to local heating. The tendency for impaired low frequency pulsations of the blood flow associated with endothelial and neurogenic activities in both diabetes groups was observed. Local thermal tests induced variations in perfusion and its spectral characteristics, which were different in the groups under study. In our opinion, the obtained preliminary results can be a basis for further research and provide a deeper understanding of pathological processes that drive microvascular abnormalities caused by diabetes mellitus

    Blood flow oscillations as a signature of microvascular abnormalities

    Get PDF
    Laser Doppler flowmetry (LDF) was utilized for blood ow measurements. Wavelet analysis was used to identify spectral characteristics of the LDF signal in patients with rheumatic diseases and diabetes mellitus. Baseline measurements were applied for both pathological groups. Blood flow oscillations analyses were performed by means of the wavelet transform. Higher baseline perfusion was observed in both pathological groups in comparison to controls. Differences in the spectral properties between the groups studied were revealed. The results obtained demonstrated that spectral properties of the LDF signal collected in basal conditions may be the signature of microvasculature functional state

    Peculiarities of local blood microcirculation in patients with psoriasis

    Get PDF
    Local hemodynamic parameters were studied by means of laser Doppler flowmetry in 15 patients with psoriasis in the stationary stage, who have plaques on the inner surface of the forearm. LDF signals recorded at the site of psoriatic lesions of the tissue as well as in the intact tissue at a distance of 1-2 cm from the affected area were analysed. LDF signals were postprocessed by continuous wavelet transform using the Morlet wavelet

    Pilot studies of age-related changes in blood perfusion in two different types of skin

    Get PDF
    Laser Doppler flowmetry (LDF) was utilized to assess age-related changes in the blood microcirculation at the skin sites with different morphology and regulation. The LDF signals obtained from the glabrous skin of the middle finger pad and nonglabrous skin on the dorsal wrist surface were analyzed. Statistically higher baseline perfusion was observed in the zone with glabrous skin in the older group of volunteers compared to younger participants. Observed site-specific and age-related differences in perfusion can be used in the future experimental design for the studies of the blood microcirculation system in patients with different pathologies

    Laser doppler spectrum decomposition applied in diagnostics of microcirculatory disturbances

    Get PDF
    Laser Doppler flowmetry (LDF) is widely used to study blood microcirculation in the skin. However, during tradition signal processing based on the integral estimations of the power spectrum of detector photocurrent, the significant part of the information about the skin blood ow is lost. In this study, we propose to analyse the distribution of the blood perfusion over the Doppler shift frequencies, which correlate with the RBC velocity. This approach provides localisation of the blood ow oscillations in different subranges of the Doppler shift. The method applied together with the wavelet analysis has been tested in healthy volunteers and patients with psoriasis on the unaffected surface of the skin. It was revealed, that the significant difference in the amplitude of myogenic oscillations is allocated in the region of the low frequency Doppler shift (1-200 Hz). This frequency region can be associated with the signal from slow components of the skin microcirculation, that can point out on a different state of the lymphatic system of the skin in psoriasis

    Incremental residual polarization of human skin caused by aging

    Get PDF
    Significance The study of the effect of aging on the optical properties of biological tissues, in particular polarization, is important in the development of new diagnostic approaches. Aim This work aims to provide a comprehensive analysis of the factors and mechanisms that contribute to the alteration of skin polarization properties caused by aging, using polarization-sensitive hyperspectral imaging measurements and Monte Carlo simulation. Approach Our investigation involved both experimental studies of in vivo human skin of volunteers of different ages and computational modeling that accounted for changes in the absorption and scattering properties of the skin model. Specifically, we analyzed alterations in the degree of linear polarization (DOLP) to better understand the impact of aging on skin polarization properties. Results A statistically significant increase in the DOLP was found for the elderly group. At the same time, there was no correlation between changes in polarization and the calculated blood volume fraction parameter for different ages. According to the simulation results, it was also found that a change in the scattering properties of biological tissues has a more significant effect on the change in polarizing light compared to the change in absorption. Conclusions The results of the work prove that the sensitivity of polarization imaging to age- or pathological-related skin changes may be primarily due to changes in scattering, which in turn is associated with changes in the collagen fibers of the dermis. The proposed technique shows promise for in vivo non-invasive real-time assessment of age-associated skin changes and can also be extended to monitor changes associated with the development of age-related pathologies

    Fibre-optic probe for fluorescence diagnostics with blood influence compensation

    Get PDF
    To minimise the influence of blood content on the fluorescence measurements in vivo, a fibre optical probe combining fluorescence and diffuse reflectance measurements was developed. For the inverse solution of the blood content recovery, a set of neural networks trained by the Monte Carlo generated learning set was used. An approach of fluorescence measurements triggered by simultaneous real-time measurements of blood content in living tissue during moderate changes in contact pressure of the optic probe is proposed. The method allows one to decrease the necessary pressure on the probe as well as increase the repeatability of the measurements. The developed approach was verified in a series of experiments on volunteers with fluorescence excitation at 365 nm and 450 nm. The proposed technology is of particular interest in the development of new fluorescence-based optical biopsy systems

    Wearable laser Doppler sensors for evaluating the nutritive and shunt blood flow

    Get PDF
    This study is devoted to the trials of wearable diagnostic system that implements the laser Doppler flowmetry technique to analyse the blood microcirculation. We do preliminary test with involvement of limited group of healthy volunteers of different age and in patients with type 2 diabetes. During the series of measurements, the microcirculation parameters was measured for 10 minutes in the palmar surfaces of the big toes and in the inner sides of the upper thirds of the shins. A statistically significant differences was found in bypass index, nutritive and shunt blood ow in shins between older group of volunteers and patients' group as well as in shunt blood flow in fingers between younger and older groups of volunteers

    Studies of age-related changes in blood perfusion coherence using wearable blood perfusion sensor system

    Get PDF
    Laser Doppler flowmetry (LDF) was used for detection of age-related changes in the blood microcirculation. The LDF signal was simultaneously recorded from the 3rd fingers' pads of both hands. Amplitudes of the blood flow oscillations and wavelet coherence of the signals were used for the data analysis. A statistical difference in the synchronisation of myogenic oscillations was found between the two studied age groups. Myogenic oscillations of blood perfusion in the younger group had a higher wavelet coherence parameter than in the older group. Observed site-specific and age-related differences in blood perfusion can be used in the future in the design of experimental studies of the blood microcirculation system in patients with different pathologies

    Wearable sensor system for multipoint measurements of blood perfusion: pilot studies in patients with diabetes mellitus

    Get PDF
    The growing interest in the development of new wearable electronic devices for mobile healthcare provides great opportunities for the development of methods for assessing blood perfusion in this direction. Laser Doppler flowmetry (LDF) is one of the promising methods. A fine analysis of capillary blood ow structure and rhythm in the time and frequency domains, coupled with a new possibility of round-the-clock monitoring can provide valuable diagnostic information about the state of microvascular blood ow. In this study, wearable implementation of laser Doppler flowmetry was utilised for microcirculatory function assessment in patients with diabetes and healthy controls of two distinct age groups. Four wearable laser Doppler flowmetry monitors were used for the analysis of blood microcirculation. Thirty-seven healthy volunteers and 18 patients with type 2 diabetes mellitus participated in the study. The results of the studies have shown that the average perfusion differs between healthy volunteers of distinct age groups and between healthy volunteers of the younger age group and patients with diabetes mellitus. It was noted that the average level of perfusion measured on the wrist in the two groups of healthy volunteers has no statistically significant differences found in similar measurements on the fingertips. The wearable implementation of LDF can become a truly new diagnostic interface to monitor cardiovascular parameters, which could be of interest for diagnostics of conditions associated with microvascular disorders
    corecore