689 research outputs found
Emittance growth in linear induction accelerators
The Dual-Axis Radiographic Hydrotest (DARHT) facility uses bremsstrahlung
radiation source spots produced by the focused electron beams from two linear
induction accelerators (LIAs) to radiograph large hydrodynamic experiments
driven by high explosives. Radiographic resolution is determined by the size of
the source spot, and beam emittance is the ultimate limitation to spot size. On
the DARHT Axis-II LIA we measure an emittance higher than predicted by
theoretical simulations, and even though this axis produces sub-millimeter
source spots, we are exploring ways to improve the emittance. Some of the
possible causes for the discrepancy have been investigated using
particle-in-cell (PIC) codes, although most of these are discounted based on
beam measurements. The most likely source of emittance growth is a mismatch of
the beam to the magnetic transport, which can cause beam halo.Comment: 20th Int. Conf. on High-Power Particle Beams, Washington, DC, May,
201
Recommended from our members
Modern electron accelerators for radiography
Over the past dozen years or so there have been significant advances in electron accelerators designed specifically for radiography of hydrodynamic experiments. Accelerator technology has evolved to accomodate the radiographers' contitiuing quest for multiple images in t h e and space:, improvements in electron beam quality have resulted in smaller radiographic spot sizes for better resolution, while higher radiation do% now provides imprcwed penetration of large, dense objects. Inductive isolation and acceleration techniques have played a ley rob in these advances
Recommended from our members
Ka-band microwave generation using the Smith-Purcell effect
The CERETRON microwave generator concept relies on the conversion of intense relativistic electron beam (REB) energy into highpower microwave emission through the Smith-Purcell effect. We report initial results from experiments with the production of Ka-band Smith-Purcell radiation generated by a 50-kA, 2.8-MeV beam propagated through a cylindrical transmission grating with lambda/sub 0/ = 1 cm. These experiments were performed without a quasi-optical resonator, and the output was limited by breakdown of the grating and by limited access through the 90-kG magnet coil. Nevertheless, the measured power output from these initial experiments was about 7 kW in the Ka band
Millennial-Scale Climate Variability during the Last Glacial Period in the Tropical Andes
Millennial-scale climate variation during the Last Glacial period is evident in many locations worldwide, but it is unclear if such variation occurred in the interior of tropical South America, and, if so, how the low-latitude variation was related to its high-latitude counterpart. A high-resolution record, derived from the deep drilling of sediments on the floor of Lake Titicaca in the southern tropical Andes, is presented that shows clear evidence of millennial-scale climate variation between ~60 and 20 ka BP. This variation is manifested by alternations of two interbedded sedimentary units. The two units have distinctive sedimentary, geochemical, and paleobiotic properties that are controlled by the relative abundance of terrigenous or nearshore components versus pelagic components. The sediments of more terrigenous or nearshore nature likely were deposited during regionally wetter climates when river transport of water and sediment was higher, whereas the sediments of more pelagic character were deposited during somewhat drier climates regionally. The majority of the wet periods inferred from the Lake Titicaca sediment record are correlated with the cold events in the Greenland ice cores and North Atlantic sediment cores, indicating that increased intensity of the South American summer monsoon was part of near-global scale climate excursions
Recommended from our members
Development of Imploding Liners With Kinetic Energies {Gt} 100 MJ and Their Applications
The Los Alamos program in High Energy Density Physics is developing high performance imploding liners as sources of high energy density environments for experimental physics applications. High performance liners are, for these purposes, liners with high velocity, 100 MJ or more kinetic energy at 20-50 MJ/cm of height. They must have sufficient azimuthal symmetry, axial uniformity and density to perform as high quality impactors on central, cylindrical targets. Scientific applications of such liners are numerous and varied. For example, the properties of materials at extreme energy densities can be assessed in such an experimental environment. The physics of plasmas near solid density can be studied and hydrodynamics experiments at high Mach number (above 5?) in materials that are near solid density and significantly ionized can be conducted. In addition, liners with substantial kinetic energy and good integrity at velocities of one to a few cm/microsec make good implosion drivers for fusion plasmas in the context of magnetized target fusion and MAGO
Recommended from our members
Conceptual Design for High Mass Imploding Liner Experiments
We have summarized some of the motivation behind high energy liner experiments. We have identified the 100-cm-diameter Disk Explosive-Magnetic Gene promising candidate for powering such experiments and described a phenomenological modeling approach used to understand the limits of DEMG operation. We have explored the liner implosion parameter space that can be addressed by such systems and have selected a design point from which to develop a conceptual experiment. We have applied the phenomenological model to the point design parameters and used 1 D MHD tools to assess the behavior of the liner for parameters at the design point. We have not to optimized the choice of pulse power or liner parameters. We conclude that operating in the velocity range of 10-20 km/s, kinetic energies around 100 MJ are practical with currents approaching 200 MA in the liner. Higher velocities (up to almost 40 km/s) are achieved on the inner surface of a thick liner when the liner collapses to I -cm radius. At 6-cm radius the non- optimized liners explored here are attractive drivers for experiments exploring the compression of magnetized plasmas and at 1 cm they are equally attractive drivers for shock wave experiments in the pressure range of 30-100 Mbar. An experiment based on this design concept is scheduled to be conducted in VNIIEF in August 1996
Hearing the voices of older adult patients: processes and findings to inform health services research
Background
Clinical academic research and service improvement is planned using Patient and Public Involvement and Engagement (PPIE) but older PPIE participants are consulted less often due to the perception that they are vulnerable or hard to engage.
Objectives
To consult frail older adults about a recently adopted service, discharge to assess (D2A), and to prioritise services improvements and research topics associated with the design and delivery of discharge from hospital. To use successive PPIE processes to enable a permanent PPIE panel to be established.
Participants
Following guidance from an established hospital PPI panel 27 older adult participants were recruited. Participants from Black, Asian and Minority Ethnic (BAME) communities, affluent and non-affluent areas and varied social circumstances were included.
Methods
Focus groups and individual interviews were conducted in participants own homes or nearby social venues.
Results
Priorities for discharge included remaining independent despite often feeling lonely at home; to remain in hospital if needed; and for services to ensure effective communication with families. The main research priority identified was facilitating independence, whilst establishing a permanent PPIE panel involving older adults was viewed favourably.
Conclusions
Taking a structured approach to PPIE enabled varied older peoples’ voices to express their priorities and concerns into early discharge from hospital, as well as enabling the development of health services research into hospital discharge planning and management. Older people as participants identified research priorities after reflecting on their experiences. Listening and reflection enabled researchers to develop a new “Community PPIE Elders Panel” to create an enduring PPIE infrastructure for frail older housebound people to engage in research design, development and dissemination
The occurrence and characterization of Campylobacter jejuni and C. coli in organic pigs and their outdoor environment
The occurrence and species distribution of thermophilic Campylobacter was investigated in organic outdoor pigs. An increased exposure of outdoor pigs to C. jejuni from the environment may cause a shift from a normal dominance of C. coli to more C. jejuni, which may imply a concern of reduced food safety.
Bacteriological methods for determination of Campylobacter excretion level were combined with colony-blot hybridization and real-time PCR for specific detection of C. jejuni in pigs. Campylobacter was isolated from pigs (n = 47), paddock environment (n = 126) and wildlife (n = 44), identified to species by real-time PCR and sub-typed by serotyping (Penner) and pulse-field gel electrophorsis (PFGE) genotyping.
All pigs excreted Campylobacter (103–107 CFU g1 faeces) from the age of 8–13-weeks old. C. jejuni was found in 29% of pigs in three consecutive trials and always in minority to C. coli (0.3–46%). C. jejuni and C. coli were isolated from 10% and 29% of the environmental samples, respectively, while crow-birds and rats harboured C. jejuni. Individual pigs hosted several strains (up to nine serotypes). The paddock environment was contaminated with C. coli serotypes similar to pig isolates, while most of the C. jejuni serotypes differed. C. jejuni isolates of different origin comprised few similar serotypes, just one identical genotype was common between pigs, environment and birds.
In conclusion, the occurrence of C. jejuni varied considerably between the three groups of outdoor pigs. Furthermore, transfer of C. jejuni to the outdoor pigs from the nearby environment was not predominant according to the subtype dissimilarities of the obtained isolates
Heparin molecularly imprinted surfaces for the attenuation of complement activation in blood
Heparin-imprinted synthetic polymer surfaces with the ability to attenuate activation of both the complement and the coagulation system in whole blood were successfully produced. Imprinting was achieved using a template coated with heparin, a highly sulfated glycosaminoglycan known for its anticoagulant properties. The N,N'-diacryloylpiperazine-methacrylic acid copolymers were characterized using goniometry, AFM and XPS. The influence of the molecular imprinting process on morphology and template rebinding was demonstrated by radioligand binding assays. Surface hemocompatibility was evaluated using human whole blood without anticoagulants followed by measurement of complement activation markers C3a and sC5b-9 and platelet consumption as a surrogate coagulation activation marker. The observed low thrombogenicity of this copolymer combined with the attenuation of complement activation induced by the molecular imprint offer potential for the development of self-regulating surfaces with important potential clinical applications. We propose a mechanism for the observed phenomena based upon the recruitment of endogenous sulfated glycosaminoglycans with heparin-like activities
- …