28 research outputs found

    Inter- and intra-observer variability in Sonographic measurements of the cross-sectional diameters and area of the umbilical cord and its vessels during pregnancy

    Get PDF
    Background. The purpose of the study was to evaluate inter- and intra-observer variability in sonographic measurements of the cross-sectional area of the umbilical cord and the diameters of its vessels in low-risk pregnancies of 12 to 40 weeks of gestation. Methods. A prospective cross sectional study was performed in 221 pregnant women at different gestational ages. Measurements were carried out also by a second observer to evaluate inter-observer variability and repeated once again by the first observer to assess intra-observer variability. The linear correlation between the measurements (Spearman's coefficient of correlation) and their reliability through the intraclass correlation coefficient (ICC), the Cronbach's alpha coefficient and the limits of agreement proposed by Bland and Altman were evaluated. Results. The results showed that inter-observer and intra-observer variability did not show any significant difference between examiners. A good linear correlation between the measurements and reliability was obtained, with values of R, ICC and Cronbach's alpha all above the standard limits. Conclusion. It is possible to conclude that inter- and intra-observer variability in the measurements of the umbilical cord and its vessels was small; their reliability and agreement were good. © 2008 Barbieri et al; licensee BioMed Central Ltd

    Fetal Movement Counting Improved Identification of Fetal Growth Restriction and Perinatal Outcomes – a Multi-Centre, Randomized, Controlled Trial

    Get PDF
    Background Fetal movement counting is a method used by the mother to quantify her baby's movements, and may prevent adverse pregnancy outcome by a timely evaluation of fetal health when the woman reports decreased fetal movements. We aimed to assess effects of fetal movement counting on identification of fetal pathology and pregnancy outcome. Methodology In a multicentre, randomized, controlled trial, 1076 pregnant women with singleton pregnancies from an unselected population were assigned to either perform fetal movement counting from gestational week 28, or to receive standard antenatal care not including fetal movement counting (controls). Women were recruited from nine Norwegian hospitals during September 2007 through November 2009. Main outcome was a compound measure of fetal pathology and adverse pregnancy outcomes. Analysis was performed by intention-to-treat. Principal Findings The frequency of the main outcome was equal in the groups; 63 of 433 (11.6%) in the intervention group, versus 53 of 532 (10.7%) in the control group [RR: 1.1 95% CI 0.7–1.5)]. The growth-restricted fetuses were more often identified prior to birth in the intervention group than in the control group; 20 of 23 fetuses (87.0%) versus 12 of 20 fetuses (60.0%), respectively, [RR: 1.5 (95% CI 1.0–2.1)]. In the intervention group two babies (0.4%) had Apgar scores <4 at 1 minute, versus 12 (2.3%) in the control group [RR: 0.2 (95% CI 0.04–0.7)]. The frequency of consultations for decreased fetal movement was 71 (13.1%) and 57 (10.7%) in the intervention and control groups, respectively [RR: 1.2 (95% CI 0.9–1.7)]. The frequency of interventions was similar in the groups. Conclusions Maternal ability to detect clinically important changes in fetal activity seemed to be improved by fetal movement counting; there was an increased identification of fetal growth restriction and improved perinatal outcome, without inducing more consultations or obstetric intervention

    Dopplerfluxometria no estudo da circulação fetal: revisão do aspecto segurança Doppler velocimetry in the study of the fetal circulation: review on safety

    No full text
    Os autores apresentam os métodos Doppler e sua evolução no estudo da circulação fetal, dando ênfase à segurança e aos bioefeitos. Os aparelhos de ultra-sonografia utilizados correntemente funcionam com índice térmico máximo e índice mecânico automaticamente mantidos em níveis inferiores a 1,0. Até os dias atuais, não foi descrita lesão biológica em fetos humanos submetidos ao Doppler diagnóstico. Portanto, o Doppler pulsado, o colorido e o "power" Doppler são seguros na exposição ultra-sonográfica do pré-natal.<br>The authors review the Doppler imaging methods and their evolution for the study of the fetal circulation emphasizing safety and bioeffects. Ultrasound machines work with thermal and mechanical indexes that are automatically kept under 1.0. Up to date, there have been no reports on biological lesions in human fetuses caused by diagnostic Doppler. Consequently, color, pulsed and power Doppler sonography are considered safe in prenatal exposure
    corecore