17 research outputs found

    Challenges in coupled on-line-on-mine-real time mineralogical and chemical analyses on drill cores

    Get PDF
    The SOLSA project aims to develop an innovative on-line-on-mine-real-time expert system, combining sonic drilling, mineralogical and chemical characterization and data treatment. Ideally, this combination, highly demanded by mining and metallurgical companies, will speed up exploration, mining and processing. In order to evaluate the instrumental parameters for the SOLSA expert system, portable and laboratory analyses have been performed on four samples with contrasting lithologies: siliceous breccia, serpentinized harzburgite, sandstone and granite. More precisely, we evaluated the influence of the surface state of the sample on the signals obtained by portable X-Ray Fluorescence (pXRF) for chemistry and portable Infra-Red spectroscopy (pIR) for mineralogy. In addition, laboratory Raman spectroscopy, X-Ray Diffraction (XRD), XRF and ICP-OES laboratory analyses were performed to compare surface bulk mineralogical and chemical analyses. This presentation highlights (1) the importance of coupling chemical and mineralogical analytical technologies to obtain most complete information on samples, (2) the effect of the sample surface state on the XRF and IR signals from portable instruments. The last point is crucial for combined instrumental on-line sensor design and the calibration of the different instruments, especially in the case of pXRF

    3D Imaging on heterogeneous surfaces on laterite drill core materials

    Get PDF
    The SOLSA project aims to construct an analytical expert system for on-line-on-mine-real-time mineralogical and geochemical analyses on sonic drilled cores. A profilometer is indispensable to obtain reliable and quantitative data from RGB and hyperspectral cameras, and to get 3D definition of close-to-surface objects such as rheology (grain shape, grain size, fractures and vein systems), material hardness and porosities. Optical properties of minerals can be analyzed by focusing on the reflectance. Preliminary analyses were performed with the commercial scan control profilometer MI-CRO-EPSILON equipped with a blue 405 nm laser on a conveyor belt (depth resolution: 10 μm; surface resolution: 30x30 μm2 (maximum resolution; 1m drill core/4 min). Drill core parts and rocks with 4 different surface roughness states: (1) sonic drilled, (2) diamond saw-cut, polished at (3) 6 mm and (4) 0.25 μm were measured (see also abstract Duée et al. this volume). The ΜICRO- EPSILON scanning does not detect such small differences of surface roughness states. Profilometer data can also be used to access rough mineralogical identification of some mineral groups like Fe-Mg silicates, quartz and feldspars). Drill core parts from a siliceous mineralized breccia and laterite with high and deep porosity and fractures were analyzed. The determination of holes’ convexity and fractures) is limited by the surface/depth ratio. Depending on end-user’s needs, parameters such as fracture densities and mineral content should be combined, and depth and surface resolutions should be optimized, to speed up “on-line-on-mine-real- time” mineral and chemical analyses in order to reach the target of about 80 m/day of drilled core

    Efficient long-term open-access data archiving in mining industries

    Get PDF
    Efficient data collection, analysis and preservation are needed to accomplish adequate business decision making. Long-lasting and sustainable business operations, such as mining, add extra requirements to this process: data must be reliably preserved over periods that are longer than that of a typical software life-cycle. These concerns are of special importance for the combined on-line-on-mine-real-time expert system SOLSA (http://www.solsa-mining.eu/) that will produce data not only for immediate industrial utilization, but also for the possible scientific reuse. We thus applied the experience of scientific data publishing to provide efficient, reliable, long term archival data storage. Crystallography, a field covering one of the methods used in the SOLSA expert system, has long traditions of archiving and disseminating crystallographic data. To that end, the Crystallographic Interchange Framework (CIF, [1]) was developed and is maintained by the International Union of Crystallography (IUCr). This framework provides rich means for describing crystal structures and crystallographic experiments in an unambiguous, human- and machine- readable way, in a standard that is independent of the underlying data storage technology. The Crystallography Open Database (COD, [2]) has been successfully using the CIF framework to maintain its open-access crystallographic data collection for over a decade [3,4]. Since the CIF framework is extensible it is possible to use it for other branches of knowledge. The SOLSA system will generate data using different methods of material identification: XRF, XRD, Raman, IR and DRIFT spectroscopy. For XRD, the CIF is usable out-of-the-box, since we can rely on extensive data definition dictionaries (ontologies) developed by the IUCr and the crystallographic community. For spectroscopic techniques such dictionaries, to our best knowledge, do not exist; thus, the SOLSA team is developing CIF dictionaries for spectroscopic techniques to be used in the SOLSA expert system. All dictionaries will be published under liberal license and communities are encourage to join the development, reuse and extend the dictionaries where necessary. These dictionaries will enable access to open data generated by SOLSA by all interested parties. The use of the common CIF framework will ensure smooth data exchange among SOLSA partners and seamless data publication from the SOLSA project

    Challenges in coupled on-line-on-mine-real time mineralogical and chemical analyses on drill cores

    No full text
    International audienceThe SOLSA project aims to develop an innovative on-line-on-mine-real-time expert system, combining sonic drilling, mineralogical and chemical characterization and data treatment. Ideally, this combination, highly demanded by mining and metallurgical companies, will speed up exploration, mining and processing. In order to evaluate the instrumental parameters for the SOLSA expert system, portable and laboratory analyses have been performed on four samples with contrasting lithologies: siliceous breccia, serpentinized harzburgite, sandstone and granite. More precisely, we evaluated the influence of the surface state of the sample on the signals obtained by portable X-Ray Fluorescence (pXRF) for chemistry and portable Infra-Red spectroscopy (pIR) for mineralogy. In addition, laboratory Raman spectroscopy, X-Ray Diffraction (XRD), XRF and ICP-OES laboratory analyses were performed to compare surface bulk mineralogical and chemical analyses. This presentation highlights (1) the importance of coupling chemical and mineralogical analytical technologies to obtain most complete information on samples, (2) the effect of the sample surface state on the XRF and IR signals from portable instruments. The last point is crucial for combined instrumental on-line sensor design and the calibration of the different instruments, especially in the case of pXRF

    Challenges in coupled on-line-on-mine-real time mineralogical and chemical analyses on drill cores

    Get PDF
    International audienceThe SOLSA project aims to develop an innovative on-line-on-mine-real-time expert system, combining sonic drilling, mineralogical and chemical characterization and data treatment. Ideally, this combination, highly demanded by mining and metallurgical companies, will speed up exploration, mining and processing. In order to evaluate the instrumental parameters for the SOLSA expert system, portable and laboratory analyses have been performed on four samples with contrasting lithologies: siliceous breccia, serpentinized harzburgite, sandstone and granite. More precisely, we evaluated the influence of the surface state of the sample on the signals obtained by portable X-Ray Fluorescence (pXRF) for chemistry and portable Infra-Red spectroscopy (pIR) for mineralogy. In addition, laboratory Raman spectroscopy, X-Ray Diffraction (XRD), XRF and ICP-OES laboratory analyses were performed to compare surface bulk mineralogical and chemical analyses. This presentation highlights (1) the importance of coupling chemical and mineralogical analytical technologies to obtain most complete information on samples, (2) the effect of the sample surface state on the XRF and IR signals from portable instruments. The last point is crucial for combined instrumental on-line sensor design and the calibration of the different instruments, especially in the case of pXRF

    Challenges in coupled on-line-on-mine-real time mineralogical and chemical analyses on drill cores

    No full text
    The SOLSA project aims to develop an innovative on-line-on-mine-real-time expert system, combining sonic drilling, mineralogical and chemical characterization and data treatment. Ideally, this combination, highly demanded by mining and metallurgical companies, will speed up exploration, mining and processing. In order to evaluate the instrumental parameters for the SOLSA expert system, portable and laboratory analyses have been performed on four samples with contrasting lithologies: siliceous breccia, serpentinized harzburgite, sandstone and granite. More precisely, we evaluated the influence of the surface state of the sample on the signals obtained by portable X-Ray Fluorescence (pXRF) for chemistry and portable Infra-Red spectroscopy (pIR) for mineralogy. In addition, laboratory Raman spectroscopy, X-Ray Diffraction (XRD), XRF and ICP-OES laboratory analyses were performed to compare surface bulk mineralogical and chemical analyses. This presentation highlights (1) the importance of coupling chemical and mineralogical analytical technologies to obtain most complete information on samples, (2) the effect of the sample surface state on the XRF and IR signals from portable instruments. The last point is crucial for combined instrumental on-line sensor design and the calibration of the different instruments, especially in the case of pXRF

    Impact of heterogeneities and surface roughness on pXRF, pIR, XRD and Raman analyses: Challenges for on-line, real-time combined mineralogical and chemical analyses on drill cores and implication for “high speed” Ni-laterite exploration

    No full text
    International audienceOn-line, real-time chemical and mineralogical analyses on drill cores are highly demanded by mining companies. However, they are a challenge because of drill core surface state and sample heterogeneities. We selected four rock samples: highly porous, siliceous breccia and serpentinized harzburgite coming from the base of a nickel laterite profile in New Caledonia which were sonic drilled, and fine grained, homogeneous sandstone and coarse grained granite which were diamond drilled and provided by Eijkelkamp Sonic Drill with unknown origin. The samples were analysed at five surface states (diamond or sonic drilled, cut as squares, polished at 6 and 0.25 μm, powdered <80 μm) by portable XRF spectroscopy (pXRF) in mining and soil modes and portable infrared spectroscopy (pIR, Visible and Near Infrared-Short Wave Infrared range (VNIR-SWIR)). A total of 52 pXRF and 200 pIR analyses were performed per sample at each surface state. This study shows that the surface state has minor influence on the results of the portable instruments. By comparing pIR and pXRF results with laboratory devices (Raman spectroscopy, XRD with Rietveld refinement, XRF spectroscopy and ICP-AES), we evidence the lower and less accurate information obtained from handheld instruments in terms of chemistry and mineralogy. The porosity and grain size effect on the measurement need to be taken into consideration for on-line drill core analyses. We show that the combination of complementary analytical techniques helps to overcome the drawbacks of the core texture and of the precision of portable instruments in order to define the regions of interest (ROI) for mining companies. We also demonstrate that a precise pXRF calibration is mandatory and that the concentration of light elements (Si, Mg), even if not accurate, shows sufficient contrast along the lateritic profile for ROI definition
    corecore