2,894 research outputs found

    Rapid temporal evolution of radiation from non-thermal electrons in solar flares

    Get PDF
    Solutions of the time dependent Fokker-Planck equation was found for accelerated electrons undergoing Coulomb collisions in a magnetized, fully ionized plasma. An exact solution was found for arbitrary pitch angle and energy distribution in a uniform background plasma. Then, for an inhomogeneous plasma, a solution was found for particles with small pitch angles. These solutions were used to calculate the temporal evolution of bremsstrahlung x-rays from short bursts of nonthermal electron beams, and these spectra were compared with observed high time resolution spectra of short timescale solar hard x-ray bursts. It is shown that the observed softening in time of the spectra rules out a homogeneous background and therefore the possibility of electrons being confined to the corona either because of converging magnetic field or high densities. The inhomogeneous solution was also applied to a model with constant coronal density and exponentially rising chromospheric density. The spectra are shown to be consistent with that produced by a collimated beam of electrons accelerated in the corona with certain given conditions. These conditions could be violated if large pitch angle electrons are present

    Development of a numerical solution to the time dependent kinetic equation

    Get PDF
    A numerical solution was developed for the time dependent Fokker-Planck equation for arbitrary distributions of electrons injected into a magnetized plasma. The code which includes energy loss and pitch angle scattering due to Coulomb collisions and changes in pitch angle due to inhomogeneous magnetic fields was calibrated and tested. The numerical method is versatile so that other scattering or radiation terms can be easily included. Using this code many processes associated with the impulsive phase of solar flares will be investigated

    Dynamic optical filtration

    Get PDF
    A dynamic optical filtration system and method effectively blocks bright light sources without impairing view of the remainder of the scene. A sensor measures light intensity and position so that selected cells of a shading matrix may interrupt the view of the bright light source by a receptor. A beamsplitter may be used so that the sensor may be located away from the receptor. The shading matrix may also be replaced by a digital micromirror device, which selectively sends image data to the receptor

    The ratio of microwaves to X-rays in solar flares: The case for the thick target model

    Get PDF
    The expected ratio of synchrotron microwave radiation to bremsstrahlung X-rays for thick target, thin target, and multithermal solar flare models is calculated. The calculations take into account the variation of the microwave to X-ray ratio with X-ray spectral index. The theoretical results are compared with observed ratios of a sample of 51 solar flares with well known spectral index. From this it is concluded that the nonthermal thick target model with a loop length of and order of 10 to the 9th power cm and a magnetic field of 500 + or - 200 G provides the best fit to the data. The thin target and multithermal models require unreasonably large density or pressure and/or low magnetic field to match the data

    Organic vapor discrimination with chemiresistor arrays of temperature modulated tin-oxide nanowires and thiolate-monolayer-protected gold nanoparticles

    Full text link
    This paper explores the discrimination of organic vapors with arrays of chemiresistors (CRs) employing interface layers of tin-oxide nanowires (NWs) and thiolate-monolayer-protected gold nanoparticles (MPNs). The former devices use contact-printed mats of NWs on micro-hotplate membranes to bridge a pair of metal electrodes. Oxidation at the NW surface causes changes in charge transport, the temperature dependence of which differs among different vapors, permitting vapor discrimination. The latter devices use solvent cast films of MPNs on interdigital electrodes operated at room temperature. Sorption into the organic monolayers causes changes in film tunneling resistance that differ among different vapors and MPN structures, permitting vapor discrimination. Here, we compare the performance and assess the 'complementarity' of these two types of sensors. Calibrated responses from an NW CR operated at two different temperatures and from a set of four different MPN CRs were generated for three test vapors: n-hexane, toluene, and nitromethane. This pooled data set was then analyzed using principal components regression classification models with varying degrees of random error superimposed on the responses via Monte Carlo simulation in order to estimate the rates of recognition/discrimination for arrays comprising different combinations of sensors. Results indicate that the diversity of most of the dual MPN-CR arrays exceeds that of the dual NW-CR array. Additionally, in assessing all possible arrays of 4–6 CR sensors, the recognition rates of the hybrid arrays(i.e. MPN + NW) were no better than that of the 4-sensor array containing only MPN CRs.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/90786/1/0957-4484_22_12_125501.pd

    Herschel SPIRE Fourier Transform Spectrometer: Calibration of its Bright-source Mode

    Get PDF
    The Fourier Transform Spectrometer (FTS) of the Spectral and Photometric Imaging REceiver (SPIRE) on board the ESA Herschel Space Observatory has two detector setting modes: (a) a nominal mode, which is optimized for observing moderately bright to faint astronomical targets, and (b) a bright-source mode recommended for sources significantly brighter than 500 Jy, within the SPIRE FTS bandwidth of 446.7-1544 GHz (or 194-671 microns in wavelength), which employs a reduced detector responsivity and out-of-phase analog signal amplifier/demodulator. We address in detail the calibration issues unique to the bright-source mode, describe the integration of the bright-mode data processing into the existing pipeline for the nominal mode, and show that the flux calibration accuracy of the bright-source mode is generally within 2% of that of the nominal mode, and that the bright-source mode is 3 to 4 times less sensitive than the nominal mode.Comment: 15 pages, 16 figures, accepted for publication in Experimental Astronom

    The effect of HCl and steam on cyclic CO2 capture performance in calcium looping systems

    Get PDF
    Calcium looping is CO2 capture technology that is considered to be technically feasible at an industrial scale using a variety of fuels such as natural gas, coals, biomass, refuse derived fuels, and biofuels. Unfortunately, many of these fuels contain significant quantities of chlorine which principally converts to gaseous HCl during combustion or gasification. To date, very few studies have examined the effect of HCl on sorbent CO2 capture performance using calcium-based sorbents under realistic carbonation and calcination conditions. In this work, experiments were conducted using thermogravimetric analysis and fixed bed reactor testing to determine the effect of HCl addition during carbonation and calcination over repeated cycles using a Canadian limestone. The presence of HCl was found to increase sorbent reactivity towards CO2 capture when steam was injected during calcination. The resulting decomposition of CaCl2 to CaO during calcination caused changes in the particle morphology, which in turn decreased the CO2 diffusional resistance during carbonation. Fixed bed test results provided confirmation of full sorbent dechlorination under typical oxy-fuel calcination conditions. It was shown that both particle surface area and pore volume were higher during tests where HCl was present during carbonation and that greater than 99% HCl capture could be achieved without adversely affecting sorbent CO2 capture performance when steam was present during both carbonation and calcination

    Combined calcium looping and chemical looping combustion for post‐combustion carbon dioxide capture: process simulation and sensitivity analysis

    Get PDF
    In this work, a combined calcium looping and chemical looping combustion (CaL--CLC) technology is simulated at thermodynamic equilibrium conditions and the results in terms of efficiency, power production, and solids circulation rates are compared with the case of using CaL alone. In addition, a new solids looping configuration in the CaL--CLC process is proposed with the purpose of mitigating the loss of calcium oxide conversion after high cycle numbers. Simulations show an improved process efficiency of the CaL--CLC method compared with CaL alone (34.2 vs. 31.2 % higher heat value) and an increased power output (136 vs. 110 MWe additional power) due to the higher energy requirement to preheat the reactants. A sensitivity analysis of the process operating parameters highlights the particular importance of the temperature difference between reactors, which has a strong impact on the required mass of solids circulating in the loops. Finally, partial carbon dioxide capture scenarios are considered and indicate that lower capture levels are suitable to match regulation targets

    A Gravitational Tractor for Towing Asteroids

    Full text link
    We present a concept for a spacecraft that can controllably alter the trajectory of an Earth threatening asteroid using gravity as a towline. The spacecraft hovers near the asteroid with thrusters angled outward so the exhaust does not impinge on the surface. This deflection method is insensitive to the structure, surface properties, and rotation state of the asteroid.Comment: 4 pages, 1 figure - to be published in Natur

    Increased lymphangiogenesis in joints of mice with inflammatory arthritis

    Get PDF
    Angiogenesis is involved in the pathogenesis of inflammatory arthritis, but little is known about the role of lymphangiogenesis in this setting. Here, we examined whether tumor necrosis factor (TNF) stimulates osteoclast precursors (OCPs) to produce the lymphatic growth factor, vascular endothelial growth factor-C (VEGF-C), and induce lymphangiogenesis. We used TNF-transgenic (Tg) mice and mice with serum-induced arthritis. OCPs were purified by fluorescence-activated cell sorting of CD11b+/Gr-1-/lo blood or bone marrow cells and subjected to microarray analysis or were generated from spleen or joint cells and treated with TNF. Expression of VEGFs was analyzed and examined by real-time reverse transcription-polymerase chain reaction and Western blotting. Immunostaining and magnetic resonance imaging were used to quantify lymphatic vessels and volumes of synovium and draining lymph nodes. TNF stimulated VEGF-C expression by OCPs and increased nuclear factor-kappa B (NF-ÎșB) binding to an NF-ÎșB sequence in the VEGF-C promoter. OCPs from joints of TNF-Tg mice express high levels of VEGF-C. Lymphatic vessel numbers and size were markedly increased in joint sections of TNF-Tg mice and mice with serum-induced arthritis. The severity of synovitis correlated with draining lymph node size. In summary, TNF induces OCPs to produce VEGF-C through NF-ÎșB, leading to significantly increased lymphangiogenesis in joints of arthritic mice. The lymphatic system may play an important role in the pathogenesis of inflammatory arthritis
    • 

    corecore