63 research outputs found

    Cryogenic silicon surface ion trap

    Full text link
    Trapped ions are pre-eminent candidates for building quantum information processors and quantum simulators. They have been used to demonstrate quantum gates and algorithms, quantum error correction, and basic quantum simulations. However, to realise the full potential of such systems and make scalable trapped-ion quantum computing a reality, there exist a number of practical problems which must be solved. These include tackling the observed high ion-heating rates and creating scalable trap structures which can be simply and reliably produced. Here, we report on cryogenically operated silicon ion traps which can be rapidly and easily fabricated using standard semiconductor technologies. Single 40^{40}Ca+^+ ions have been trapped and used to characterize the trap operation. Long ion lifetimes were observed with the traps exhibiting heating rates as low as nˉ˙=\dot{\bar{n}}= 0.33 phonons/s at an ion-electrode distance of 230 μ\mum. These results open many new avenues to arrays of micro-fabricated ion traps.Comment: 12 pages, 4 figures, 1 tabl

    A frequency-tunable nanomembrane mechanical oscillator with embedded quantum dots

    Get PDF
    Hybrid systems consisting of a quantum emitter coupled to a mechanical oscillator are receiving increasing attention for fundamental science and potential applications in quantum technologies. In contrast to most of the presented works, in which the oscillator eigenfrequencies are irreversibly determined by the fabrication process, we present here a simple approach to obtain frequency-tunable mechanical resonators based on suspended nanomembranes. The method relies on a micromachined piezoelectric actuator, which we use both to drive resonant oscillations of a suspended Ga(Al)As membrane with embedded quantum dots and to fine tune their mechanical eigenfrequencies. Specifically, we excite oscillations with frequencies of at least 60 MHz by applying an AC voltage to the actuator and tune the eigenfrequencies by at least 25 times their linewidth by continuously varying the elastic stress state in the membranes through a DC voltage. The light emitted by optically excited quantum dots is used as sensitive local strain gauge to monitor the oscillation frequency and amplitude. We expect that our method has the potential to be applicable to other optomechanical systems based on dielectric and semiconductor membranes possibly operating in the quantum regime.Comment: 17 pages, 4 figure

    External validation and extension of a diagnostic model for obstructive coronary artery disease: A cross-sectional predictive evaluation in 4888 patients of the Austrian Coronary Artery disease Risk Determination in Innsbruck by diaGnostic ANgiography (CARDIIGAN) cohort

    Get PDF
    __Objective__ To externally validate and extend a recently proposed prediction model to diagnose obstructive coronary artery disease (CAD), with the ultimate aim to better select patients for coronary angiography. __Design__ Analysis of individual baseline data of a prospective cardiology cohort. __Setting__ Single-centre secondary and tertiary cardiology clinic. __Participants__ 4888 patients with suspected CAD, without known previous CAD or other heart diseases, who underwent an elective coronary angiography between 2004 and 2008 as part of the prospective Coronary Artery disease Risk Determination In Innsbruck by diaGnostic ANgiography (CARDIIGAN) cohort. Relevant data were recorded as in routine clinical practice. __Main outcome measures__ The probability of obstructive CAD, defined as a stenosis of minimally 50% diameter in at least one of the main coronary arteries, estimated with the predictors age, sex, type of chest pain, diabetes status, hypertension, dyslipidaemia, smoking status and laboratory data. Missing predictor data were multiply imputed. Performance of the suggested models was evaluated according to discrimination (area under the receiver operating characteristic curve, depicted by the c statistic) and calibration. Logistic regression modelling was applied for model updating. __Results__ Among the 4888 participants (38% women and 62% men), 2127 (44%) had an obstructive CAD. The previously proposed model had a c statistic of 0.69 (95% CI 0.67 to 0.70), which was lower than the expected c statistic while correcting for case mix (c=0.80). Regarding calibration, there was overprediction of risk for high-risk patients. All logistic regression coefficients were smaller than expected, especially for the predictor â € chest pain'. Ext

    Direct Flow Medical vs. Edwards Sapien 3 Prosthesis: A Propensity Matched Comparison on Intermediate Safety and Mortality

    Get PDF
    Aims: To compare intermediate performance and mortality rates in patients, who underwent transcatheter aortic valve implantation (TAVI) with two different types of prostheses: Edwards Sapien 3 (ES3) and Direct Flow Medical (DFM).Methods and Results: 42 consecutive patients implanted with a DFM prosthesis for severe aortic stenosis were matched 1:1 with an equal number of patients, who received an ES3 during the same period. Primary endpoint was mortality. MACE, as a composite of all-cause death, stroke, and re-do-procedure (valve-in-valve), was defined as secondary endpoint. Moreover, we compared NYHA class, NT-proBNP-levels and the extent of restenosis. Patients were followed for 2 years. DFM patients showed echocardiographic elevated mean pressure gradients compared to ES3 patients before discharge (11.2 mmHg ± 5.3 vs. 3.5 mmHg ± 2.7; p < 0.001) and upon 6-months follow-up (20.3 mmHg ± 8.8 vs. 12.3 mmHg ± 4.4; p < 0.001). ES3 candidates showed superior NYHA class at follow-up (p = 0.001). Kaplan-Meier analysis revealed significantly worse survival in patients receiving a DFM prosthesis compared to ES3 (Breslow p = 0.020). MACE occurred more often in DFM patients compared to ES3 (Breslow p = 0.006).Conclusions: Patients receiving DFM valve prostheses showed worse survival and higher rates in MACE compared to ES3. Prosthesis performance regarding mean pressure gradients and patients' NYHA class also favored ES3

    Farmer surveys in Europe suggest that specialized, intensive farms were more likely to perceive negative impacts from COVID-19.

    Get PDF
    It has been shown that the COVID-19 pandemic affected some agricultural systems more than others, and even within geographic regions, not all farms were affected to the same extent. To build resilience of agricultural systems to future shocks, it is key to understand which farms were affected and why. In this study, we examined farmers' perceived robustness to COVID-19, a key resilience capacity. We conducted standardized farmer interviews (n = 257) in 15 case study areas across Europe, covering a large range of socio-ecological contexts and farm types. Interviews targeted perceived livelihood impacts of the COVID-19 pandemic on productivity, sales, price, labor availability, and supply chains in 2020, as well as farm(er) characteristics and farm management. Our study corroborates earlier evidence that most farms were not or only slightly affected by the first wave(s) of the pandemic in 2020, and that impacts varied widely by study region. However, a significant minority of farmers across Europe reported that the pandemic was "the worst crisis in a lifetime" (3%) or "the worst crisis in a decade" (7%). Statistical analysis showed that more specialized and intensive farms were more likely to have perceived negative impacts. From a societal perspective, this suggests that highly specialized, intensive farms face higher vulnerability to shocks that affect regional to global supply chains. Supporting farmers in the diversification of their production systems while decreasing dependence on service suppliers and supply chain actors may increase their robustness to future disruptions. Supplementary Information The online version contains supplementary material available at 10.1007/s13593-022-00820-5

    Burden of onchocerciasis-associated epilepsy: First estimates and research priorities

    Get PDF
    __Background:__ Since the 1990s, evidence has accumulated of an increased prevalence of epilepsy in onchocerciasis-endemic areas in Africa as compared to onchocerciasis-free areas. Although the causal relationship between onchocerciasis and epilepsy has yet to be proven, there is likely an association.

    Visualizing Knowledge: A Decision Matrix for Choosing Visualization Techniques

    No full text
    Knowledge workers who want to apply knowledge visualization have to determine which visual representation and thereupon which visualization tool is suitable for their needs. To support knowledge workers in this sophisticated problem a systematic approach is presented that matches typical tasks in knowledge management to visualizationtechniques that support these tasks. Knowledge workers are provided with a three-dimensional decision matrix that enables them to identify a suitable visualization technique for a certain knowledge problem. To be able to systematically evaluate and identify adequate visualization techniques a set of evaluation criteria is introduced.Informationstechnologie und Informationsmanagemen

    Single-mode interband cascade lasers emitting below 2.8 ÎĽm

    Get PDF
    Financial support by the European Commission within the WideLase Seventh Framework Programme Project (Grant Agreement No.: 318798) is gratefully acknowledged.In this work, single-mode distributed feedback (DFB) interband cascade laser (ICL) devices with record short wavelength emission below 2.8 μm are presented. Pulsed measurements based on broad area laser devices with a cavity of 2 mm length and 150 μm width showed threshold current densities of 383 A/cm2 at T = 20 °C and a characteristic temperature T0 of 67 K. Fabricated DFB devices were operated in continuous wave mode at room temperature, with threshold currents of 57 mA and demonstrated side mode suppression ratios of larger than 25 dB. The devices showed current tuning ranges of 7 nm and total (including drive current and temperature) tuning ranges of 12 nm, with respective tuning rates of 21 nm/W, 0.13 nm/mA and 0.29 nm/K. Using the full spectral gain bandwidth of the underlying ICL material, single-mode DFB emission was observed within a wavelength range of 150 nm utilizing different DFB grating periods.Publisher PDFPeer reviewe
    • …
    corecore