    Incidental finding of a giant intracardiac angioma infiltrating both ventricles in a 35-year-old woman: a case report

    Get PDF
    Background: Primary cardiac tumors are rare and often asymptomatic or present with unspecific symptoms. Benign cardiac tumors of vascular origin are especially rare, with only few existing data in the literature. Case presentation: A 35-year-old Caucasian female patient presented to our department with an asymptomatic giant intracardiac angioma infiltrating both ventricles. Evaluation of this tumor involved electrocardiography, echocardiography, cardiac magnetic resonance imaging, coronary angiography, an open myocardial biopsy, and histological examination of the resected specimen. Because our patient was asymptomatic, she was managed conservatively with regular follow-up. We discuss the treatment options available in comparison with similar cases. Conclusion: Diagnosis and therapy of benign cardiac tumors, especially of asymptomatic lesions, can be a challenge. There is no evidence available to help in the management of such patients. An extensive evaluation is needed with different imaging modalities, and case-specific decisions should be made that involve experts in cardiology, cardio-oncology, and heart surgery

    Fully digital data processing during cardiovascular implantable electronic device follow-up in a high-volume tertiary center

    Get PDF
    Background Increasing numbers of patients with cardiovascular implantable electronic devices (CIEDs) and limited follow-up capacities highlight unmet challenges in clinical electrophysiology. Integrated software (MediConnect®) enabling fully digital processing of device interrogation data has been commercially developed to facilitate follow-up visits. We sought to assess feasibility of fully digital data processing (FDDP) during ambulatory device follow-up in a high-volume tertiary hospital to provide guidance for future users of FDDP software. Methods A total of 391 patients (mean age, 70 years) presenting to the outpatient department for routine device follow-up were analyzed (pacemaker, 44%; implantable cardioverter defibrillator, 39%; cardiac resynchronization therapy device, 16%). Results Quality of data transfer and follow-up duration were compared between digital (n = 265) and manual processing of device data (n = 126). Digital data import was successful, complete and correct in 82% of cases when early software versions were used. When using the most recent software version the rate of successful digital data import increased to 100%. Software-based import of interrogation data was complete and without failure in 97% of cases. The mean duration of a follow-up visit did not differ between the two groups (digital 18.7 min vs. manual data transfer 18.2 min). Conclusions FDDP software was successfully implemented into the ambulatory follow-up of patients with implanted pacemakers and defibrillators. Digital data import into electronic patient management software was feasible and supported the physician’s workflow. The total duration of follow-up visits comprising technical device interrogation and clinical actions was not affected in the present tertiary center outpatient cohort

    Postcardiac injury syndrome after cardiac implantable electronic device implantation

    No full text
    Background!#!Postcardiac injury syndrome (PCIS) is an inflammatory complication that derives from injury to the epicardium, myocardium, or endocardium. It occurs after trauma, myocardial infarction, percutaneous coronary intervention, cardiac surgery, intracardiac ablation, and implantation of cardiac implantable electronic device (CIED). In this study we assessed the incidence of PCIS after CIED implantation and its possible risk factors.!##!Material and methods!#!All patients who received CIED implantation at Heidelberg University Hospital between 2000 and 2014 were evaluated (n = 4989 patients). Clinical data including age, sex, underlying cardiac disease, type of implanted CIED, location of electrode implantation, clinical symptoms, time of symptom onset of PCIS, therapy, and outcome were extracted and analyzed.!##!Results!#!We identified 19 cases of PCIS in 4989 patients, yielding an incidence of 0.38%. The age of patients with PCIS ranged from 39 to 86 years. Dilated cardiomyopathy (DCM) as underlying cardiac disease and right atrial (RA) lead implantation had a significant association with occurrence of PCIS (p = 0.045 in DCM and p < 0.001 in RA lead implantation). Dyspnea, chest pain, dry cough, and fever were the most frequently reported symptoms in patients with PCIS. Pericardial and pleura effusion as well as elevated C‑reactive protein (CRP), increased erythrocyte sedimentation rate (ESR), and leukocytosis were the most common findings.!##!Conclusion!#!To the best of our knowledge, this is the largest cohort evaluating the incidence of PCIS after CIED implantation. The data show that PCIS is a rare complication after CIED implantation and occurs more frequently in patients with DCM and those with RA lead implantation. Although rare and mostly benign, PCIS can lead to potentially lethal complications and physicians must be aware of its symptoms

    Economic evaluation of remote monitoring of patients with an implantable cardiac defibrillator (REMOTE-CIED study)

    No full text
    INTRODUCTION: Remote patient monitoring (RPM) of heart failure patients has the potential to reduce healthcare resource use and costs, but current evidence has been inconclusive. This study aims assess the impact of RPM of heart failure patients with an implantable cardioverter defibrillator on medical resource use, direct medical costs, quality-adjusted life years (QALYs), and travel time of patients, and to estimate its commercial headroom in the Netherlands and Germany. METHODS: Data from the REMOTE-CIED randomized controlled trial were used to calculate differences in length of hospital stay, outpatient clinic visits, telephone consults, emergency room visits, and travel time between patients on in-clinic follow-up and RPM in the Netherlands, Germany, and France. Incremental cardiac-related healthcare costs and QALYs were calculated and used to calculate the commercial headroom of RPM in the Netherlands and Germany. The impact of imputation, parameter, and case-mix uncertainty on these outcomes was explored using probabilistic analysis. RESULTS: Length of hospitalization, number of unscheduled admissions, and number of outpatient visits were lower in the remote monitoring group in all three countries. Number of hospital admissions was higher, and number of calls was lower in the Netherlands and Germany but not in France. Costs were lower in both the Netherlands (-€1041, 95% confidence interval (CI): -€3308, €1005) and Germany (-€2865, 95% CI: -€7619, €1105), while incremental effectiveness differed: -0.003 (95% CI: -0.114, 0.107) QALY in the Netherlands and +0.086 (95% CI: -0.083, 0.256) in Germany. Commercial headroom was estimated at €881 (95% CI: -€5430, €7208) in the Netherlands and €5005 (95% CI: -€1339, €11,960) in Germany. DISCUSSION: RPM was found to result in reduced medical resource use and travel time. Whether it is cost saving or cost effective strongly depends on the costs of remote monitoring. TRIAL REGISTRATION NUMBER AND TRIAL REGISTER: ClinicalTrials.gov: NCT01691586

    Novel Endothelial Cell-Specific AQP1 Knockout Mice Confirm the Crucial Role of Endothelial AQP1 in Ultrafiltration during Peritoneal Dialysis.

    No full text
    The water channel aquaporin-1 (AQP1) mediates about 50% ultrafiltration during a 2-hour hypertonic dwell in global AQP1 knockout (AQP1-/-) mice. Although AQP1 is widely expressed in various cell types including mesothelial cells, the ultrafiltration has been assumed to be mediated via endothelial AQP1 of the peritoneum. The partial embryonic lethality and reduced body weight in AQP1-/- mice may reflect potential confounding phenotypic effects evoked by ubiquitous AQP1 deletion, which may interfere with functional analysis of endothelial AQP1. Using a Cre/loxP approach, we generated and characterised endothelial cell- and time-specific AQP1 knockout (AQP1fl/fl; Cdh5-Cre+) mice. Compared to controls, AQP1fl/fl; Cdh5-Cre+ mice showed no difference in an initial clinical and biological analysis at baseline, including body weight and survival. During a 1-hour 3.86% mini-peritoneal equilibration test (mini-PET), AQP1fl/fl; Cdh5-Cre+ mice exhibited strongly decreased indices for AQP1-related transcellular water transport (43.0% in net ultrafiltration, 93.0% in sodium sieving and 57.9% in free water transport) compared to controls. The transport rates for small solutes of urea and glucose were not significantly altered. Our data provide the first direct experimental evidence for the functional relevance of endothelial AQP1 to the fluid transport in peritoneal dialysis and thereby further validate essential predictions of the three-pore model of peritoneal transport

    Remote monitoring of implantable cardioverter defibrillators : Patient experiences and preferences for follow-up

    Get PDF
    Background: Patient satisfaction with remote patient monitoring (RPM) of implantable cardioverter defibrillators (ICDs) seems to be high, yet knowledge on long-term patient experiences is limited. The European REMOTE-CIED study explored patients' experiences with RPM, examined patient's preferences for ICD follow-up, and identified determinants of patient's preferences in the first 2 years postimplantation. Methods: European heart failure patients (N = 300; median age = 66 years [interquartile range (IQR) = 59-73], and 22% female) with a first-time ICD received a Boston Scientific LATITUDE RPM system (Marlborough, MA, USA) and had scheduled in-clinic follow-ups once a year. Patients completed questionnaires at 1-2 weeks and also at 3, 6, 12, and 24 months postimplantation and clinical data were obtained from their medical records. Patient evaluation data were analyzed descriptively, and Student's t-tests/Man-Whitney U tests or Chi-square tests/Fisher's exact tests were performed to examine determinants of patient preferences. Results: At 2 years postimplantation, the median patient satisfaction score with the RPM system was 9 out of 10 (IQR = 8-10), despite 53% of the patients experiencing issues (eg, failure to transmit data). Of the 221 patients who reported their follow-up preferences, 43% preferred RPM and 19% preferred in-clinic follow-up. Patients with a preference for RPM were more likely to be higher educated (P = 0.04), employed (P = 0.04), and equipped with a new LATITUDE model (P = 0.04), but less likely to suffer from chronic obstructive pulmonary disease (P = 0.009). Conclusion: In general, patients were highly satisfied with RPM, but a subgroup preferred in-clinic follow-up. Therefore, physicians should include patients’ concerns and preferences in the decision-making process, to tailor device follow-up to individual patients’ needs and preferences

    Effect of remote monitoring on patient-reported outcomes in European heart failure patients with an implantable cardioverter-defibrillator : primary results of the REMOTE-CIED randomized trial

    No full text
    AIMS: The European REMOTE-CIED study is the first randomized trial primarily designed to evaluate the effect of remote patient monitoring (RPM) on patient-reported outcomes in the first 2 years after implantation of an implantable cardioverter-defibrillator (ICD). METHODS AND RESULTS: The sample consisted of 595 European heart failure patients implanted with an ICD compatible with the Boston Scientific LATITUDE® RPM system. Patients were randomized to RPM plus a yearly in-clinic ICD check-up vs. 3-6-month in-clinic check-ups alone. At five points during the 2-year follow-up, patients completed questionnaires including the Kansas City Cardiomyopathy Questionnaire and Florida Patient Acceptance Survey (FPAS) to assess their heart failure-specific health status and ICD acceptance, respectively. Information on clinical status was obtained from patients' medical records. Linear regression models were used to compare scores between groups over time. Intention-to-treat and per-protocol analyses showed no significant group differences in patients' health status and ICD acceptance (subscale) scores (all Ps > 0.05). Exploratory subgroup analyses indicated a temporary improvement in device acceptance (FPAS total score) at 6-month follow-up for secondary prophylactic in-clinic patients only (P < 0.001). No other significant subgroup differences were observed. CONCLUSION: Large clinical trials have indicated that RPM can safely and effectively replace most in-clinic check-ups of ICD patients. The REMOTE-CIED trial results show that patient-reported health status and ICD acceptance do not differ between patients on RPM and patients receiving in-clinic check-ups alone in the first 2 years after ICD implantation.ClinicalTrials.gov Identifier: NCT01691586

    Effect of remote monitoring on patient-reported outcomes in European heart failure patients with an implantable cardioverter-defibrillator:Primary results of the REMOTE-CIED randomized trial

    No full text
    Aims The European REMOTE-CIED study is the first randomized trial primarily designed to evaluate the effect of remote patient monitoring (RPM) on patient-reported outcomes in the first 2 years after implantation of an implantable cardioverter-defibrillator (ICD). Methods and results The sample consisted of 595 European heart failure patients implanted with an ICD compatible with the Boston Scientific LATITUDE® RPM system. Patients were randomized to RPM plus a yearly in-clinic ICD check-up vs. 3–6-month in-clinic check-ups alone. At five points during the 2-year follow-up, patients completed questionnaires including the Kansas City Cardiomyopathy Questionnaire and Florida Patient Acceptance Survey (FPAS) to assess their heart failure-specific health status and ICD acceptance, respectively. Information on clinical status was obtained from patients’ medical records. Linear regression models were used to compare scores between groups over time. Intention-to-treat and per-protocol analyses showed no significant group differences in patients’ health status and ICD acceptance (subscale) scores (all Ps > 0.05). Exploratory subgroup analyses indicated a temporary improvement in device acceptance (FPAS total score) at 6-month follow-up for secondary prophylactic in-clinic patients only (P < 0.001). No other significant subgroup differences were observed. Conclusion Large clinical trials have indicated that RPM can safely and effectively replace most in-clinic check-ups of ICD patients. The REMOTE-CIED trial results show that patient-reported health status and ICD acceptance do not differ between patients on RPM and patients receiving in-clinic check-ups alone in the first 2 years after ICD implantation
    • …