293 research outputs found

    Time-elapsed synchrotron-light microstructural imaging of femoral neck fracture

    Get PDF
    Time-elapsed micro-computed-tomography (μCT) imaging allows studying bone micromechanics. However, no study has yet performed time-elapsed μCT imaging of human femoral neck fractures. We developed a protocol for time-elapsed synchrotron μCT imaging of the microstructure in the entire proximal femur, while inducing clinically-relevant femoral neck fractures. Three human cadaver femora (females, age: 75-80 years) were used. The specimen-specific force to be applied at each load step was based on the specimens' strength estimated a priori using finite-element analysis of clinical CT images. A radio-transparent compressive stage was designed for loading the specimens while recording the applied load during synchrotron μCT scanning. The total μCT scanning field of view was 146 mm wide and 131 mm high, at 29.81 µm isotropic pixel size. Specimens were first scanned unloaded, then under incremental load steps, each equal to 25% of the estimated specimens' strength, and ultimately after fracture. Fracture occurred after 4-5 time-elapsed load steps, displaying sub-capital fracturing of the femoral neck, in agreement with finite-element predictions. Time-elapsed μCT images, co-registered to those of the intact specimen, displayed the proximal femur microstructure under progressive deformation up to fracture. The images showed (1) a spatially heterogeneous deformation localized in the proximal femoral head; (2) a predominantly elastic recovery, after load removal, of the diaphyseal and trochanteric regions and; (3) post-fracture residual displacements, mainly localized in the fractured region. The time-elapsed μCT imaging protocol developed and the high resolution images generated, made publicly available, may spur further research into human femur micromechanics and fracture.Saulo Martelli, Egon Perill

    PV Cell Characteristic Extraction to Verify Power Transfer Efficiency in Indoor Harvesting System

    Get PDF
    A method is proposed to verify the efficiency of low-power harvesting systems based on Photovoltaic (PV) cells for indoor applications and a Fractional Open-Circuit Voltage (FOCV) technique to track the Maximum Power Point (MPP). It relies on an algorithm to reconstruct the PV cell Power versus Voltage (P-V) characteristic measuring the open circuit voltage and the voltage/current operating point but not the short-circuit current as required by state-of-the-art algorithms. This way the characteristic is reconstructed starting from the two values corresponding to standard operation modes of dc-dc converters implementing the FOCV Maximum Power Point Tracking (MPPT) technique. The method is applied to a prototype system: an external board is connected between the transducer and the dc-dc converter to measure the open circuit voltage and the voltage/current operating values. Experimental comparisons between the reconstructed and the measured P-V characteristics validate the reconstruction algorithm. Experimental results show the method is able to clearly identify the error between the transducer operating point and the one corresponding to the maximum power transfer, whilst also suggesting corrective action on the programmable factor of the FOCV technique. The proposed technique therefore provides a possible way of estimating MPPT efficiency without sampling the full P-V characteristic

    Body anthropometry and bone strength conjointly determine the risk of hip fracture in a sideways fall

    Get PDF
    We hypothesize that variations of body anthropometry, conjointly with the bone strength, determine the risk of hip fracture. To test the hypothesis, we compared, in a simulated sideways fall, the hip impact energy to the energy needed to fracture the femur. Ten femurs from elderly donors were tested using a novel drop-tower protocol for replicating the hip fracture dynamics during a fall on the side. The impact energy was varied for each femur according to the donor’s body weight, height and soft-tissue thickness, by adjusting the drop height and mass. The fracture pattern, force, energy, strain in the superior femoral neck, bone morphology and microarchitecture were evaluated. Fracture patterns were consistent with clinically relevant hip fractures, and the superior neck strains and timings were comparable with the literature. The hip impact energy (11 – 95 J) and the fracture energy (11 – 39 J) ranges overlapped and showed comparable variance (CV = 69 and 61%, respectively). The aBMD-based definition of osteoporosis correctly classified 7 (70%) fracture/non-fracture cases. The incorrectly classified cases presented large impact energy variations, morphology variations and large subcortical voids as seen in microcomputed tomography. In conclusion, the risk of osteoporotic hip fracture in a sideways fall depends on both body anthropometry and bone strength

    A gated oscillator clock and data recovery circuit for nanowatt wake-up and data receivers

    Get PDF
    This article presents a data-startable baseband logic featuring a gated oscillator clock and data recovery (GO-CDR) circuit for nanowatt wake-up and data receivers (WuRxs). At each data transition, the phase misalignment between the data coming from the analog front-end (AFE) and the clock is cleared by the GO-CDR circuit, thus allowing the reception of long data streams. Any free-running frequency mismatch between the GO and the bitrate does not limit the number of receivable bits, but only the maximum number of equal consecutive bits (Nm). To overcome this limitation, the proposed system includes a frequency calibration circuit, which reduces the frequency mismatch to ±0.5%, thus enabling the WuRx to be used with different encoding techniques up to Nm = 100. A full WuRx prototype, including an always-on clockless AFE operating in subthreshold, was fabricated with STMicroelectronics 90 nm BCD technology. The WuRx is supplied with 0.6 V, and the power consumption, excluding the calibration circuit, is 12.8 nW during the rest state and 17 nW at a 1 kbps data rate. With a 1 kbps On-Off Keying (OOK) modulated input and −35 dBm of input RF power after the input matching network (IMN), a 10^(−3) missed detection rate with a 0 bit error tolerance is measured, transmitting 63 bit packets with the Nm ranging from 1 to 63. The total sensitivity, including the estimated IMN gain at 100 MHz and 433 MHz, is −59.8 dBm and −52.3 dBm, respectively. In comparison with an ideal CDR, the degradation of the sensitivity due to the GO-CDR is 1.25 dBm. False alarm rate measurements lasting 24 h revealed zero overall false wake-ups

    Damage tolerance and toughness of elderly human femora

    Get PDF
    Observations of elastic instability of trabecular bone cores supported the analysis of cortical thickness for predicting bone fragility of the hip in people over 60 years of age. Here, we falsified the hypothesis that elastic instability causes minimal energy fracture by analyzing, with a micrometric resolution, the deformation and fracture behavior of entire femora. Femur specimens were obtained from elderly women aged between 66 – 80 years. Microstructural images of the proximal femur were obtained under 3 – 5 progressively increased loading steps and after fracture. Bone displacements, strain, load bearing and energy absorption capacity were analyzed. Elastic instability of the cortex appeared at early loading stages in regions of peak compression. No elastic instability of trabecular bone was observed. The subchondral bone displayed local crushing in compression at early loading steps and progressed to 8 – 16% compression before fracture. The energy absorption capacity was proportional to the displacement. Stiffness decreased to near-zero values before fracture. Three-fourth of the fracture energy (10.2 – 20.2 J) was dissipated in the final 25% force increment. Fracture occurred in regions of peak tension and shear, adjacent to the location of peak compression, appearing immediately before fracture. Minimal permanent deformation was visible along the fracture surface. Elastic instability modulates the interaction between cortical and trabecular bone promoting an elastically stable fracture behavior of the femur organ, load bearing capacity, toughness, and damage tolerance. These findings will advance current methods for predicting hip fragility

    A Novel Approach for an Integrated Straw tube-Microstrip Detector

    Full text link
    We report on a novel concept of silicon microstrips and straw tubes detector, where integration is accomplished by a straw module with straws not subjected to mechanical tension in a Rohacell ®^{\circledR} lattice and carbon fiber reinforced plastic shell. Results on mechanical and test beam performances are reported on as well.Comment: Accepted by Transactions on Nuclear Science (2005). 11 pages, 9 figures, uses lnfprep.st

    Assessing the effects of parthenolide on inflammation, bone loss, and glial cells within a collagen antibody-Induced arthritis mouse model

    Get PDF
    Rheumatoid arthritis is characterised by a chronic inflammatory response resulting in destruction of the joint and significant pain. Although a range of treatments are available to control disease activity in RA, bone destruction and joint pain exist despite suppression of inflammation. This study is aimed at assessing the effects of parthenolide (PAR) on paw inflammation, bone destruction, and pain-like behaviour in a mild collagen antibody-induced arthritis (CAIA) mouse model. CAIA was induced in BALB/c mice and treated daily with 1 mg/kg or 4 mg/kg PAR. Clinical paw inflammation was scored daily, and mechanical hypersensitivity was assessed on alternate days. At end point, bone volume and swelling in the paws were assessed using micro-CT. Paw tissue sections were assessed for inflammation and pre-/osteoclast-like cells. The lumbar spinal cord and the periaqueductal grey (PAG) and rostral ventromedulla (RVM) regions of the brain were stained for glial fibrillary acidic protein (GFAP) and ionised calcium-binding adaptor molecule 1 (IBA1) to assess for glial reactivity. Paw scores increased in CAIA mice from days 5-10 and were reduced with 1 mg/kg and 4 mg/kg PAR on days 8-10. Osteoclast-like cells on the bone surface of the radiocarpal joint and within the soft tissue of the hind paw were significantly lower following PAR treatment (p < 0.005). GFAP- and IBA1-positive cells in the PAG and RVM were significantly lower following treatment with 1 mg/kg (p < 0.0001 and p = 0.0004, respectively) and 4 mg/kg PAR (p < 0.0001 and p = 0.001, respectively). In the lumbar spinal cord, IBA1-positive cells were significantly lower in CAIA mice treated with 4 mg/kg PAR (p = 0.001). The findings indicate a suppressive effect of both low- and moderate-dose PAR on paw inflammation, osteoclast presence, and glial cell reactivity in a mild CAIA mouse model.B. Williams, F. Lees, H. Tsangari, M. R. Hutchinson, E. Perilli and T. N. Crott

    Quantifying not only bone loss, but also soft tissue swelling, in a murine inflammatory arthritis model using micro-computed tomography

    Get PDF
    In rodent models of inflammatory arthritis, bone erosion has been non-invasively assessed by micro-computed tomography (micro-CT). However, non-invasive assessments of paw swelling (oedema) are still based on clinical grading by visual evaluation, or measurements by callipers, not always reliable for the tiny mouse paws. The aim of this work was to demonstrate a novel straightforward 3D micro-CT analysis protocol capable of quantifying not only joint bone erosion, but also soft tissue swelling, from the same scans, in a rodent inflammatory arthritis model. Balb/c mice were divided into two groups: collagen antibody-induced arthritis (CAIA) and CAIA treated with prednisolone, the latter reflecting an established treatment in human rheumatoid arthritis. Clinical paw scores were recorded. On day 10, front paws were assessed by micro-CT and histology. Micro-CT measurements included paw volume (bone and soft tissue together) and bone volume at the radiocarpal joint, and bone volume from the radiocarpal to the metacarpophalangeal joint. Micro-CT analysis revealed significantly lower paw volume (−36%, P 0.5, P < 0.01). Untreated CAIA mice showed significantly higher clinical scores, higher inflammation levels histologically, cartilage and bone degradation, and pannus formation, compared with treated mice (P < 0.01). The presented novel micro-CT analysis protocol enables 3D-quantification of paw swelling at the micrometre level, along with the typically assessed bone erosion, using the same images/scans, without altering the scanning procedure or using contrast agents.E. Perilli, M. Cantley, V. Marino, T. N. Crotti, M. D. Smith, D. R. Haynes and A. A. S. S. K. Dharmapatn
    • …
    corecore