892 research outputs found

    Thermoreflectance investigation of the antiferromagnetic and paramagnetic phases of Cr

    Get PDF
    Thermoreflectance measurements have been performed on Cr single crystals at several temperatures above and below the Néel temperature. We observe dramatic changes induced by the magnetic phase transition. In contrast, static optical data fail to show appreciable differences in the (0.5-5.0)-eV photon-energy range. Magnetic ordering gives rise to the disappearance of transitions involving specific regions of the Fermi surface. New critical-point absorptions appear at the boundaries of the new Brillouin zone in antiferromagnetic Cr. Most of the observed experimental features have been identified by comparison with recent band-structure calculations

    Fine needle cytology of complex thyroid nodules.

    Get PDF
    OBJECTIVE: To evaluate whether a preliminary aspiration (ASP) of the cystic component and/or using spinal needles in complex thyroid nodules (CTN) could improve the adequacy of cytological sampling. METHODS: Between January 2004 and December 2006, 386 consecutive patients with CTN were enrolled in this prospective investigation. Ultrasound (US) fine needle aspiration cytology (FNAC) of the solid component of the nodule (one nodule per patient) was performed using two different 25 gauge needles, with (Yale Spinal, YS) or without (Neolus, NS) a stylet, in alternate sequence on consecutive patients. In addition, a subgroup of patients presenting larger cystic component (approximately 50%) was submitted to total aspiration of the cystic component (ASP+) or not submitted (ASP-) before US-FNAC, in alternate sequence within each needle type group. All the samplings were performed by a single endocrinologist. RESULTS: Adequate specimens were observed in 163 (84.5%) and 183 (94.8%) nodules investigated by NS and YS respectively. Sampling with the stylet needle was associated with an overall significant reduction of non-diagnostic specimens (15.5% vs 5.2% by NS and YS respectively, P < 0.001). The favourable result obtained with YS was independent from preliminary aspiration of the cystic component (ASP+: 14.8% vs 5.7% by NS and YS; ASP-: 16.2% vs 4.8%, not significant). A logistic regression analysis, taking into account nodule size and presence of intranodal vascularity at eco-colour evaluation of the solid component, confirmed that needle type was the only significant predictor of successful sampling (odds ratio 3.6 (95% confidence interval 1.7-7.6), P < 0.001). CONCLUSIONS: Our data show that adopting stylet needles to perform FNAC in CTN may significantly improve the percentage of adequate sampling. On the other hand, preliminary aspiration of CTN with large cystic component does not add any advantage

    Modified percutaneous ethanol injection of parathyroid adenoma in primary hyperparathyroidism.

    Get PDF
    Surgery is the treatment of choice for symptomatic primary hyperparathyroidism; unlikely few patients do not meet established surgical criteria or have comorbid conditions that prohibit surgery. In these subjects, medical therapy alone offers little hope for a sustained long normocalcemic period. However percutaneous ethanol injection (PEI) may represent an alternative therapeutic procedure. It is currently in use for the treatment of secondary or tertiary hyperparathyroidism, however, few studies or case reports suggest it for the treatment of primary hyperparathyroidism. Moreover, little information is available about the long-term follow-up, where incomplete necrosis or the spreading of ethanol in the surrounding tissues is often reported. We believe that many of the side effects could be correlated to procedure itself. Taking these experiences into account, we have reasoned that in order to limit these side effects, we had to modify the standard PEI procedure. We reported this preliminary experience describing our modified PEI procedure

    Prognostic value of thyrotropin receptor antibodies (TRAb) in Graves' disease: a 120 months prospective study

    Get PDF
    In most trials, at least 30-60% of patients with Graves' disease treated with antithyroid drugs relapse within 2 years after therapy withdrawal. At present, there are no prognostic parameters available early in treatment to indicate patients likely to achieve long-term remission. Because thyrotropin receptor autoantibodies (TRAb) are specific for Graves' disease, we evaluated the ability of their levels and of their rate of change to predict long-term prognosis. In our study 216 consecutive patients with newly diagnosed Graves' disease started a therapy with methimazole. Patients were treated until they achieved euthyroidism and TRAb were measured at 6-month intervals throughout a follow up of 120 months. Our study demonstrated that at the onset of hyperthyroidism patients' age, sex, fT4 levels and goiter size had no prognostic value in predicting long-term prognosis (respectively p = 0.79; p = 0.98; p = 0.83; p = 0.89). On the contrary, at the time of diagnosis TRAb titer was a good predictor of the final outcome (p<0.001); a titer equal to (or) more than 46.5 UI/L could identify patients who had never achieved long-term remission with a sensitivity of 52% and a specificity of 78%. Also fall rate of TRAb at 6 months of follow up and after therapy withdrawal were useful to predict the final outcome (p<0.001). At 6 months of follow up the time of therapy withdrawal, a decrease of TRAb lower than 52.3% or even its increase could identify patients who had never achieved permanent remission with a sensitivity of 55% and a specificity of 79.1%. No single parameter among TRAb, satisfactory identified a sub-set of patients who achieved long remission. Accordingly to our data, the best result in predicting long term remission is probably given by the presence of at least one of the two features evaluated at 6 months (TRAb titer and/or percentage of TRAb fall rate), with a sensitivity of 63% and specificity of 88%. TRAb titers evaluated both at the onset of hyperthyroidism that at 6 months of therapy or their rate of fall at 6 months and at ATD withdrawal are predictors of outcome. However, the presence of at least one, between titers of TRAb or their rate of fall at six months, resulted to be the best predictor of remission with the higher sensitivity and specificity

    Electronic structure of Nb-Mo alloys

    Get PDF
    Thermoreflectance measurements on NbxMo1−x alloys (x=0.2, 0.5, 0.8) have been carried out in the 0.5-5.0 eV energy region. Augmented-plane-wave (APW) calculations for Nb at two different lattice parameters and for Mo, as well as coherent-potential-approximation calculations (CPA), have been carried out and have been used in the interpretation of the experimental results. Several optical transitions [Σ1(EF)→Σ3, G4(EF)→G1,N2→N′1], have been identified, and their concentration dependence followed. These results contribute significantly toward putting the interpretation of the optical properties of Nb, Mo, and their alloys on a much more secure footing. In particular, it has been confirmed that while the lower conduction bands behave roughly as predicted by the rigid-band model, the higher-lying conduction bands show distinctly non-rigid-band-like behavior

    Central blood pressure assessment using 24-hour brachial pulse wave analysis

    Get PDF
    Maria Lorenza Muiesan, Massimo Salvetti, Fabio Bertacchini, Claudia Agabiti-Rosei, Giulia Maruelli, Efrem Colonetti, Anna Paini Clinica Medica, Department of Clinical and Experimental Sciences, University of Brescia, Brescia, Italy Abstract: This review describes the use of central blood pressure (BP) measurements during ambulatory monitoring, using noninvasive devices. The principles of measuring central BP by applanation tonometry and by oscillometry are reported, and information on device validation studies is described. The pathophysiological basis for the differences between brachial and aortic pressure is discussed. The currently available methods for central aortic pressure measurement are relatively accurate, and their use has important clinical implications, such as improving diagnostic and prognostic stratification of hypertension and providing a more accurate assessment of the effect of treatment on BP. Keywords: aortic blood pressure measurements, ambulatory monitoring, pulse wave analysi

    Blood pressure control in Italy: analysis of clinical data from 2005-2011 surveys on hypertension

    Get PDF
    Introduction: Blood pressure (BP) control is poorly achieved in hypertensive patients, worldwide. Aim: We evaluated clinic BP levels and the rate of BP control in hypertensive patients included in observational studies and clinical surveys published between 2005 and 2011 in Italy. Methods: We reviewed the medical literature to identify observational studies and clinical surveys on hypertension between January 2005 and June 2011, which clearly reported information on clinic BP levels, rates of BP control, proportions of treated and untreated patients, who were followed in different clinical settings (mostly in general practice, and also in outpatient clinics and hypertension centres). Results: The overall sample included 158 876 hypertensive patients (94 907 women, mean age 56.6 +/- 9.6 years, BMI 27.2 +/- 4.2 kg/m(2), known duration of hypertension 90.2 +/- 12.4 months). In the selected studies, average SBP and DBP levels were 145.7 +/- 15.9 and 87.5 +/- 9.7 mmHg, respectively; BP levels were higher in patients followed in hypertension centres (n = 10 724, 6.7%; 146.5 +/- 17.3/88.5 +/- 10.3 mmHg) than in those followed by general practitioners (n = 148 152, 93.3%; 143.5 +/- 13.9/84.8 +/- 8.9 mmHg; P < 0.01). More than half of the patients were treated (n = 91 318, 57.5%); among treated hypertensive patients, only 31 727 (37.0%) had controlled BP levels. Conclusion: The present analysis confirmed inadequate control of BP in Italy, independently of the clinical setting. Although some improvement was noted compared with a similar analysis performed between 1995 and 2005, these findings highlight the need for a more effective clinical management of hypertension

    Core level shifts of undercoordinated Pt atoms

    Get PDF
    We present the results of high-energy resolution core level photoelectron spectroscopy experiments paralleled by density functional theory calculations to investigate the electronic structure of highly undercoordinated Pt atoms adsorbed on Pt(111) and its correlation with chemical activity. Pt4f(7/2) core level binding energies corresponding to atoms in different configurations are shown to be very sensitive not only to the local atomic coordination number but also to the interatomic bond lengths. Our results are rationalized by introducing an indicator, the effective coordination, which includes both contributions. The calculated energy center of the valence 5d-band density of states, which is a well known depicter of the surface chemical reactivity, shows a noteworthy correlation with the Pt4f(7/2) core level shifts and with the effective coordination

    Encapsulation of dual emitting giant quantum dots in silica nanoparticles for optical ratiometric temperature nanosensors

    Get PDF
    Accurate temperature measurements with a high spatial resolution for application in the biomedical fields demand novel nanosized thermometers with new advanced properties. Here, a water dispersible ratiometric temperature sensor is fabricated by encapsulating in silica nanoparticles, organic capped PbS@CdS@CdS "giant" quantum dots (GQDs), characterized by dual emission in the visible and near infrared spectral range, already assessed as efficient fluorescent nanothermometers. The chemical stability, easy surface functionalization, limited toxicity and transparency of the silica coating represent advantageous features for the realization of a nanoscale heterostructure suitable for temperature sensing. However, the strong dependence of the optical properties on the morphology of the final core-shell nanoparticle requires an accurate control of the encapsulation process. We carried out a systematic investigation of the synthetic conditions to achieve, by the microemulsion method, uniform and single core silica coated GQD (GQD@SiO2) nanoparticles and subsequently recorded temperature-dependent fluorescent spectra in the 281-313 K temperature range, suited for biological systems. The ratiometric response-the ratio between the two integrated PbS and CdS emission bands-is found to monotonically decrease with the temperature, showing a sensitivity comparable to bare GQDs, and thus confirming the effectiveness of the functionalization strategy and the potential of GQD@SiO2 in future biomedical applications
    • …