1,478 research outputs found

    Interferometric length metrology for the dimensional control of ultra-stable Ring Laser Gyroscopes

    Full text link
    We present the experimental test of a method for controlling the absolute length of the diagonals of square ring laser gyroscopes. The purpose is to actively stabilize the ring cavity geometry and to enhance the rotation sensor stability in order to reach the requirements for the detection of the relativistic Lense-Thirring effect with a ground-based array of optical gyroscopes. The test apparatus consists of two optical cavities 1.32 m in length, reproducing the features of the ring cavity diagonal resonators of large frame He-Ne ring laser gyroscopes. The proposed measurement technique is based on the use of a single diode laser, injection locked to a frequency stabilized He-Ne/Iodine frequency standard, and a single electro-optic modulator. The laser is modulated with a combination of three frequencies allowing to lock the two cavities to the same resonance frequency and, at the same time, to determine the cavity Free Spectral Range (FSR). We obtain a stable lock of the two cavities to the same optical frequency reference, providing a length stabilization at the level of 1 part in 101110^{11}, and the determination of the two FSRs with a relative precision of 0.2 ppm. This is equivalent to an error of 500 nm on the absolute length difference between the two cavities

    Rotational sensitivity of the "G-Pisa" gyrolaser

    Full text link
    G-Pisa is an experiment investigating the possibility to operate a high sensitivity laser gyroscope with area less than 1m21 \rm m^2 for improving the performances of the mirrors suspensions of the gravitational wave antenna Virgo. The experimental set-up consists in a He-Ne ring laser with a 4 mirrors square cavity. The laser is pumped by an RF discharge where the RF oscillator includes the laser plasma in order to reach a better stability. The contrast of the Sagnac fringes is typically above 50% and a stable regime has been reached with the laser operating both single mode or multimode. The effect of hydrogen contamination on the laser was also checked. A low-frequency sensitivity, below 1Hz1 \rm Hz, in the range of 10−8(rad/s)/Hz10^{-8} \rm {(rad / s)/ \sqrt{Hz}} has been measured.Comment: 6 pages, 6 figures, presented at the EFTF-IFCS joint conference 200

    A 1.82 m^2 ring laser gyroscope for nano-rotational motion sensing

    Full text link
    We present a fully active-controlled He-Ne ring laser gyroscope, operating in square cavity 1.35 m in side. The apparatus is designed to provide a very low mechanical and thermal drift of the ring cavity geometry and is conceived to be operative in two different orientations of the laser plane, in order to detect rotations around the vertical or the horizontal direction. Since June 2010 the system is active inside the Virgo interferometer central area with the aim of performing high sensitivity measurements of environmental rotational noise. So far, continuous not attempted operation of the gyroscope has been longer than 30 days. The main characteristics of the laser, the active remote-controlled stabilization systems and the data acquisition techniques are presented. An off-line data processing, supported by a simple model of the sensor, is shown to improve the effective long term stability. A rotational sensitivity at the level of ten nanoradiants per squareroot of Hz below 1 Hz, very close to the required specification for the improvement of the Virgo suspension control system, is demonstrated for the configuration where the laser plane is horizontal

    A high sensitivity tool for geophysical applications: A geometrically locked Ring Laser Gyroscope

    Full text link
    This work demonstrates that a middle size ring laser gyroscope (RLG) can be a very sensitive and robust instrument for rotational seismology, even if it operates in a quite noisy environment. The RLG has a square cavity, 1.60×1.601.60\times 1.60 m2^2, and it lies in a plane orthogonal to the Earth rotational axis. The Fabry-Perot optical cavities along the diagonals of the square were accessed and their lengths were locked to a reference laser. Through a quite simple locking circuit, we were able to keep the sensor fully operative for 14 days. The obtained long term stability is of the order of 3~nanorad/s and the short term sensitivity close is to 2~nanorad/s⋅\cdotHz−1/2^{-1/2}. These results are limited only by the noisy environment, our laboratory is located in a building downtown.Comment: 9 pages, 4 figures, 25 reference

    DNA repair and antibody diversification: the 53BP1 paradigm

    Get PDF
    The DNA double-strand break (DSB) repair factor 53BP1 has long been implicated in V(D)J and class switch recombination (CSR) of mammalian lymphocyte receptors. However, the dissection of the underlying molecular activities is hampered by a paucity of studies [V(D)J] and plurality of phenotypes (CSR) associated with 53BP1 deficiency. Here, we revisit the currently accepted roles of 53BP1 in antibody diversification in view of the recent identification of its downstream effectors in DSB protection and latest advances in genome architecture. We propose that, in addition to end protection, 53BP1-mediated end-tethering stabilization is essential for CSR. Furthermore, we support a pre-DSB role during V(D)J recombination. Our perspective underscores the importance of evaluating repair of DSBs in relation to their dynamic architectural contexts

    Macrophage Activation in Follicular Conjunctivitis during the COVID-19 Pandemic

    Get PDF
    Among the symptoms of SARS-CoV-2, follicular conjunctivitis has become relevant. The conjunctiva acts as an open lymph node, reacting to the viral antigen that binds the epithelial cells, forming follicles of B cells with activated T cells and NK cells on its surface, which, in turn, talk to monocyte-derived inflammatory infected macrophages. Here, the NLRP3 inflammasome is a major driver in releasing pro-inflammatory factors such as IL-6 and caspase-1, leading to follicular conjunctivitis and bulbar congestion, even as isolated signs in the ‘asymptomatic’ patient

    Geometrical scale-factor stabilization of square cavity ring laser gyroscopes

    Get PDF
    Large frame ring laser gyros performances are ultimately limited by the instabilities of their geometrical parameters. We present the experimental activity on the GP2 ring laser gyro. GP2 is a ring laser gyro devoted to develop advanced stabilization techniques of the ring cavity geometrical scale-factor. A method based on optical interferometry has been developed for canceling the deformations of the resonator. The method is based on the measurement and stabilization of the absolute length of the cavity perimeter and of the resonators formed by the opposite cavity mirrors. The optical frequency reference in the experiment is an iodine-stabilized He-Ne laser, with a relative frequency stability of 10-11. The measurement of the absolute length of the two resonators has been demonstrated up to now on a test bench. We discuss the experimental results on GP2: the present performances as a ring laser gyro and the stabilization scheme to be implemented in the near future

    Length measurement and stabilization of the diagonals of a square area laser gyroscope

    Get PDF
    Large frame ring laser gyroscopes are top sensitivity inertial sensors able to measure absolute angular rotation rate below prad s-1 in few seconds. The GINGER project is aiming at directly measuring the Lense-Thirring effect with an 1% precision on an Earth based experiment. GINGER is based on an array of large frame ring laser gyroscopes. The mechanical design of this apparatus requires a micrometric precision in the construction and the geometry must be stabilized in order to keep constant the scale factor of the instrument. The proposed control is based on square cavities, and relies on the length stabilization of the two diagonals, which must be equal at micrometric level. GP2 is the prototype devoted to the scale factor control test. As a first step, the lengths of the diagonals of the ring cavity have been measured through an interferometric technique with a statistical accuracy of some tens of nanometers, and they have been locked to the wavelength of a reference optical standard. Continuous operation has been obtained over more than 12 h, without loss of sensitivity. GP2 is located in a laboratory with standard temperature stabilization, with residual fluctuations of the order of 1 C. Besides the demonstration of the control effectiveness, the analysis of the Sagnac frequency demonstrates that relative small and low-cost ring lasers (around one meter of side) can also achieve a sensitivity of the order of nrad s-1 in the range 0.01-10 Hz in a standard environment, which is the target sensitivity in many different applications, such as rotational seismology and next generation gravitational waves detectors

    The P2X7 Receptor 489C>T Gain of Function Polymorphism Favors HHV-6A Infection and Associates With Female Idiopathic Infertility

    Get PDF
    The P2X7 receptor (P2X7R) is an ATP-gated ion channel known for its proinflammatory activity. Despite its participation in host defense against pathogens, the role played in viral infections, notably those caused by herpes viruses, has been seldom studied. Here we investigated the effect of P2X7R expression on human herpes virus 6 A (HHV-6A) infection of P2X7R-expressing HEK293 cells. We show that functional P2X7R increases while its blockade decreases viral load. Interestingly, HHV-6A infection was enhanced in HEK293 cells transfected with P2X7R cDNA bearing the gain of function 489C>T SNP (rs208294, replacing a histidine for tyrosine at position 155). The P2X7R 489C>T polymorphism correlated with HHV-6A infection also in a cohort of 50 women affected with idiopathic infertility, a condition previously shown to correlate with HHV-6A infection. None of the infertile women infected by HHV-6A was homozygote for 489CC genotype, while on the contrary HHV-6A infection significantly associated with the presence of the rs208294 allele. Levels of soluble human leukocyte antigen G (sHLA-G), a factor promoting embryo implant, measured in uterine flushings negatively correlated with the 489TT genotype and HHV-6A infection, while proinflammatory cytokines interleukins 1α (IL-1α), 1β (IL-1β), and 8 (IL-8) positively correlated with both the 489T allele presence and viral infection. Taken together these data point to the P2X7R as a new therapeutic target to prevent HHV-6A infection and the associated infertility
    • …
    corecore