120 research outputs found

    Observational and Numerical Simulation Study of a Sequence of Eight Atmospheric Density Currents in Northern Spain

    Get PDF
    A sequence of eight atmospheric density current fronts occurred in consecutive days are identified and analyzed using micrometeorological time series and numerical simulations. Observations were collected in the context of the INTERCLE project, which took place from September 2002 to November 2003 at the CIBA (Research Centre for the Lower Atmosphere) site located over the northern Spanish plateau. Numerical simulations used the Weather Research and Forecast (WRF) model with fine horizontal resolution (1 km). Both observations and simulations agree that the arrival of the density currents are characterized by a sharp change in temperature, wind velocity, wind direction and specific humidity and a source of intermittent turbulence. However, comparison between model and observations shows that the model predicts the intrusion of the density currents earlier than is observed. In addition, wavelet techniques applied to the data help distinguish the different scales present in the events, and therefore can reveal traces of gravity waves induced by the arrival of the density currents

    Schwann cells and mesenchymal stem cells in laminin- or fibronectin-aligned matrices and regeneration across a critical size defect of 15 mm in the rat sciatic nerve

    Get PDF
    OBJECTIVE Artificial nerve guides are being developed to substitute for autograft repair after peripheral nerve injuries. However, the use of conduits is limited by the length of the gap that needs to be bridged, with the success of regeneration highly compromised in long gaps. Addition of aligned proregenerative cells and extracellular matrix (ECM) components inside the conduit can be a good strategy to achieve artificial grafts that recreate the natural environment offered by a nerve graft. The purpose of this study was to functionalize chitosan devices with different cell types to support regeneration in limiting gaps in the rat peripheral nerve. METHODS The authors used chitosan devices combined with proteins of the ECM and cells in a rat model of sciatic nerve injury. Combinations of fibronectin and laminin with mesenchymal stem cells (MSCs) or Schwann cells (SCs) were aligned within tethered collagen-based gels, which were placed inside chitosan tubes that were then used to repair a critical-size gap of 15 mm in the rat sciatic nerve. Electrophysiology and algesimetry tests were performed to analyze functional recovery during the 4 months after injury and repair. Histological analysis was performed at the midlevel and distal level of the tubes to assess the number of regenerated myelinated fibers. RESULTS Functional analysis demonstrated that SC-aligned scaffolds resulted in 100% regeneration success in a 15-mm nerve defect in this rat model. In contrast, animals that underwent repair with MSC-aligned constructs had only 90% regeneration success, and those implanted with acellular bridges had only 75% regeneration success. CONCLUSIONS These results indicate that the combination of chitosan conduits with ECM-enriched cellular gels represents a good alternative to the use of autografts for repairing long nerve gaps

    Tubulization with chitosan guides for the repair of long gap peripheral nerve injury in the rat

    Get PDF
    Biosynthetic guides can be an alternative to nerve grafts for reconstructing severely injured peripheral nerves. The aim of this study was to evaluate the regenerative capability of chitosan tubes to bridge critical nerve gaps (15 mm long) in the rat sciatic nerve compared with silicone (SIL) tubes and nerve autografts (AGs). A total of 28 Wistar Hannover rats were randomly distributed into four groups (n = 7 each), in which the nerve was repaired by SIL tube, chitosan guides of low (∼2%, DAI) and medium (∼5%, DAII) degree of acetylation, and AG. Electrophysiological and algesimetry tests were performed serially along 4 months follow-up, and histomorphometric analysis was performed at the end of the study. Both groups with chitosan tubes showed similar degree of functional recovery, and similar number of myelinated nerve fibers at mid tube after 4 months of implantation. The results with chitosan tubes were significantly better compared to SIL tubes (P < 0.01), but lower than with AG (P < 0.01). In contrast to AG, in which all the rats had effective regeneration and target reinnervation, chitosan tubes from DAI and DAII achieved 43 and 57% success, respectively, whereas regeneration failed in all the animals repaired with SIL tubes. This study suggests that chitosan guides are promising conduits to construct artificial nerve grafts

    Stabilization, Rolling, and Addition of Other Extracellular Matrix Proteins to Collagen Hydrogels Improve Regeneration in Chitosan Guides for Long Peripheral Nerve Gaps in Rats

    Get PDF
    BACKGROUND: Autograft is still the gold standard technique for the repair of long peripheral nerve injuries. The addition of biologically active scaffolds into the lumen of conduits to mimic the endoneurium of peripheral nerves may increase the final outcome of artificial nerve devices. Furthermore, the control of the orientation of the collagen fibers may provide some longitudinal guidance architecture providing a higher level of mesoscale tissue structure. OBJECTIVE: To evaluate the regenerative capabilities of chitosan conduits enriched with extracellular matrix-based scaffolds to bridge a critical gap of 15 mm in the rat sciatic nerve. METHODS: The right sciatic nerve of female Wistar Hannover rats was repaired with chitosan tubes functionalized with extracellular matrix-based scaffolds fully hydrated or stabilized and rolled to bridge a 15 mm nerve gap. Recovery was evaluated by means of electrophysiology and algesimetry tests and histological analysis 4 months after injury. RESULTS: Stabilized constructs enhanced the success of regeneration compared with fully hydrated scaffolds. Moreover, fibronectin-enriched scaffolds increased muscle reinnervation and number of myelinated fibers compared with laminin-enriched constructs. CONCLUSION: A mixed combination of collagen and fibronectin may be a promising internal filler for neural conduits for the repair of peripheral nerve injuries, and their stabilization may increase the quality of regeneration over long gaps

    MARANGONI CONVECTION INFLUENCE ON MASS TRANSFER ACROSS SPHERICAL INTERFACIAL BOUNDARY

    Full text link
    In this paper the influence of Marangoni convection on mass transfer across spherical interfacial boundary was consideredin detail. Considered issues allow to make a conclusion about necessary conditions of extraction performance to enhance mass transfer. Research results give an opportunity to define the parameters, which have a crucial influence of mass transfer intensification

    SIMULATION OF RISING DROPLET MOVEMENT WITH MOVING MESH METHODS

    Full text link
    In this paper movement of rising benzene droplets was studied experimentally and numerically. The moving mesh methods were used to simulate drop movement. Comparison of experimental and numerical results was performed with respect to instantaneous velocities and shape of rising droplets

    Terahertz displacive excitation of a coherent Raman-active phonon in V2O3

    Get PDF
    Nonlinear processes involving frequency-mixing of light fields set the basis for ultrafast coherent spectroscopy of collective modes in solids. In certain semimetals and semiconductors, generation of coherent phonon modes can occur by a displacive force on the lattice at the difference-frequency mixing of a laser pulse excitation on the electronic system. Here, as a low-frequency counterpart of this process, we demonstrate that coherent phonon excitations can be induced by the sum-frequency components of an intense terahertz light field, coupled to intraband electronic transitions. This nonlinear process leads to charge-coupled coherent dynamics of Raman-active phonon modes in the strongly correlated metal V2O3. Our results show an alternative up-conversion pathway for the optical control of Raman-active modes in solids mediated by terahertz-driven electronic excitation
    corecore