284 research outputs found

    Mixer conditions temperature of liquified gas streams

    Get PDF
    Room temperature gaseous hydrogen mixed with liquified hydrogen in a venturi produces a two- phased liquid hydrogen stream at a stable temperature. This technique is useful in laboratory testing where presently, temperature control is maintained by a calibrated heat leak that results in considerable expenditure of cryogenic refrigerants

    A unified analysis of executive pay: the case of the banking industry

    Get PDF
    This study examines executive compensation determinants in the U.S. banking industry. Multiple theories of executive pay are discussed and tested using a relatively homogenous sample. We perform an in-depth look at the corporate governance and ownership structure of the companies selected. We explore the simultaneous relationship between compensation, firm performance, and board strength, exploiting variables unique to the banking industry. Our primary finding is that after controlling for both regulatory oversight and external market discipline, a strong board is associated with higher firm performance and lower levels of executive pay, consistent with such a board of directors providing a strong monitoring function.Executives - Salaries

    Device for measuring bronchodilator delivery and response in resource-limited settings

    Get PDF

    Spacecraft rocket engine chamber insulation materials Interim report, 1 Jul. 1967 - 30 Jun. 1968

    Get PDF
    Spacecraft rocket engine chamber insulation materials - silica fabric/molybdenum foil layer, carbon fabric/tantalum foil, and fine tungsten powder in hollow zirconia microsphere matri

    Dynamic and volumetric variables reliably predict fluid responsiveness in a porcine model with pleural effusion

    Get PDF
    Background: The ability of stroke volume variation (SVV), pulse pressure variation (PPV) and global end-diastolic volume (GEDV) for prediction of fluid responsiveness in presence of pleural effusion is unknown. The aim of the present study was to challenge the ability of SVV, PPV and GEDV to predict fluid responsiveness in a porcine model with pleural effusions. Methods: Pigs were studied at baseline and after fluid loading with 8 ml kg−1 6% hydroxyethyl starch. After withdrawal of 8 ml kg−1 blood and induction of pleural effusion up to 50 ml kg−1 on either side, measurements at baseline and after fluid loading were repeated. Cardiac output, stroke volume, central venous pressure (CVP) and pulmonary occlusion pressure (PAOP) were obtained by pulmonary thermodilution, whereas GEDV was determined by transpulmonary thermodilution. SVV and PPV were monitored continuously by pulse contour analysis. Results: Pleural effusion was associated with significant changes in lung compliance, peak airway pressure and stroke volume in both responders and non-responders. At baseline, SVV, PPV and GEDV reliably predicted fluid responsiveness (area under the curve 0.85 (p<0.001), 0.88 (p<0.001), 0.77 (p = 0.007). After induction of pleural effusion the ability of SVV, PPV and GEDV to predict fluid responsiveness was well preserved and also PAOP was predictive. Threshold values for SVV and PPV increased in presence of pleural effusion. Conclusions: In this porcine model, bilateral pleural effusion did not affect the ability of SVV, PPV and GEDV to predict fluid responsiveness

    Costimulatory molecule-deficient dendritic cell progenitors (MHC class II<sup>+</sup>, CD80(dim), CD86<sup>-</sup>) prolong cardiac allograft survival in nonimmunosuppressed recipients

    Get PDF
    We have shown previously that granulocyte-macrophage colony-stimulating factor-stimulated mouse bone marrow-derived MHC class II+ dendritic cell (DC) progenitors that are deficient in cell surface expression of the costimulatory molecules B7-1 (CD8O) and B7-2 (CD86) can induce alloantigen- specific T-cell anergy in vitro. To test the in vivo relevance of these findings, 2 x 106 B10 (H2(b)) mouse bone marrow-derived DC progenitors (NLDC 145+, MHC class II+, B7-1(dim), B7-2(-/dim)) that induced T-cell hyporesponsiveness in vitro were injected systemically into normal C3H (H2(k)) recipients. Seven days later, the mice received heterotopic heart transplants from B10 donors. No immunosuppressive treatment was given. Median graft survival time was prolonged significantly from 9.5 to 22 days. Median graft survival time was also increased, although to a lesser extent (16.5 days), in mice that received third-party (BALB/c; H2(d)) DC progenitors. Ex vivo analysis of host T-cell responses to donor and third-party alloantigens 7 days after the injection of DC progenitors (the time of heart transplant) revealed minimal anti-donor mixed leukocyte reaction and cytotoxic T lymphocyte reactivity. These responses were reduced substantially compared with those of spleen cells from animals pretreated with 'mature' granulocyte- macrophage colony-stimulating factor + interleukin-4-stimulated DC (MHC class II(bright), B7-1+, B7-2(bright)), many of which rejected their heart grafts in an accelerated fashion. Among the injected donor MHC class II+ DC progenitors that migrated to recipient secondary lymphoid tissue were cells that appeared to have up-regulated cell surface B7-1 and B7-2 molecule expression. This observation may explain, at least in part, the temporary or unstable nature of the hyporesponsiveness induced by the DC progenitors in nonimmunosuppressed recipients

    Long Wave Infrared Type II Superlattice Focal Plane Array Detector

    Get PDF
    The XBn/XBp family of barrier detectors enables diffusion limited dark currents comparable with HgxCd1-xTe Rule-07 and high quantum efficiencies. SCD’s XBp type II superlattice (T2SL) detector contains InAs/GaSb and InAs/AlSb T2SLs, and was designed for the long wave infrared (LWIR) atmospheric window using k · p based modeling of the energy bands and photo-response. Wafers are grown by molecular beam epitaxy and are fabricated into focal plane array (FPA) detectors using standard FPA processes, including wet and dry etching, indium bump hybridisation, under-fill, and back-side polishing. The 640 × 512 pixel, 15 μm pitch, detector goes by the name of ‘Pelican-D LW’ and exhibits a quantum efficiency of ~ 50 per cent with background limited performance at an operating temperature of 77 K. It has a cut-off wave length of ~ 9.5 μm, with a pixel operability of above 99 per cent. The detector gives a very stable image with a residual non uniformity of below 0.04 per cent over its useful dynamic range. A new digital read-out integrated circuit has been designed so that the complete detector closely follows the configuration of SCD’s MWIR Pelican-D detector

    Outcome in patients perceived as receiving excessive care across different ethical climates : a prospective study in 68 intensive care units in Europe and the USA

    Get PDF
    Whether the quality of the ethical climate in the intensive care unit (ICU) improves the identification of patients receiving excessive care and affects patient outcomes is unknown. In this prospective observational study, perceptions of excessive care (PECs) by clinicians working in 68 ICUs in Europe and the USA were collected daily during a 28-day period. The quality of the ethical climate in the ICUs was assessed via a validated questionnaire. We compared the combined endpoint (death, not at home or poor quality of life at 1 year) of patients with PECs and the time from PECs until written treatment-limitation decisions (TLDs) and death across the four climates defined via cluster analysis. Of the 4747 eligible clinicians, 2992 (63%) evaluated the ethical climate in their ICU. Of the 321 and 623 patients not admitted for monitoring only in ICUs with a good (n = 12, 18%) and poor (n = 24, 35%) climate, 36 (11%) and 74 (12%), respectively were identified with PECs by at least two clinicians. Of the 35 and 71 identified patients with an available combined endpoint, 100% (95% CI 90.0-1.00) and 85.9% (75.4-92.0) (P = 0.02) attained that endpoint. The risk of death (HR 1.88, 95% CI 1.20-2.92) or receiving a written TLD (HR 2.32, CI 1.11-4.85) in patients with PECs by at least two clinicians was higher in ICUs with a good climate than in those with a poor one. The differences between ICUs with an average climate, with (n = 12, 18%) or without (n = 20, 29%) nursing involvement at the end of life, and ICUs with a poor climate were less obvious but still in favour of the former. Enhancing the quality of the ethical climate in the ICU may improve both the identification of patients receiving excessive care and the decision-making process at the end of life
    corecore