26 research outputs found

    Evaluation of Modified PEG-Anilinoquinazoline Derivatives as Potential Agents for EGFR Imaging in Cancer by Small Animal PET

    Get PDF
    Purpose: The in vivo evaluation of three modified polyethylene glycol (PEG)-anilinoquinazoline derivatives labeled with 124 I, 18 F, and 11 C as potential positron emission tomography (PET) bioprobes for visualizing epidermal growth factor receptor (EGFR) in cancer using small animal PET. Procedures: Xenograft mice with the human glioblastoma cell lines U138MG (lacking EGFR expression) and U87MG.wtEGFR (transfected with an overexpressing human wild-type EGFR gene) were used. Static and dynamic PET imaging was conducted for all three PEGylated compounds. Tumor necrosis, microvessel density, and EGFR levels were evaluated by histopathology and enzyme-linked immunosorbent assay. Results: Nineteen animal models were generated (two U138MG, three U87MG, 14 with both U138MG and U87MG bilateral masses). In static images, a slight increase in tracer uptake was observed in tumors, but in general, there was no retention of tracer uptake over time and no difference in uptake between U138MG and U87MG masses. In addition, no significant uptake was demonstrated in dynamic scans of the 18 F-PEG tracer. No necrosis was present except in four animals. MVD was 9.6 and 48 microvessels/×400 field in the U138GM and U87GM masses

    Comprehensive Auditing in Nuclear Medicine Through the International Atomic Energy Agency Quality Management Audits in Nuclear Medicine Program. Part 2: Analysis of Results.

    Get PDF
    The International Atomic Energy Agency has developed a program, named Quality Management Audits in Nuclear Medicine (QUANUM), to help its Member States to check the status of their nuclear medicine practices and their adherence to international reference standards, covering all aspects of nuclear medicine, including quality assurance/quality control of instrumentation, radiopharmacy (further subdivided into levels 1, 2, and 3, according to complexity of work), radiation safety, clinical applications, as well as managerial aspects. The QUANUM program is based on both internal and external audits and, with specifically developed Excel spreadsheets, it helps assess the level of conformance (LoC) to those previously defined quality standards. According to their level of implementation, the level of conformance to requested standards; 0 (absent) up to 4 (full conformance). Items scored 0, 1, and 2 are considered non-conformance; items scored 3 and 4 are considered conformance. To assess results of the audit missions performed worldwide over the last 8 years, a retrospective analysis has been run on reports from a total of 42 audit missions in 39 centers, three of which had been re-audited. The analysis of all audit reports has shown an overall LoC of 73.9 ± 8.3% (mean ± standard deviation), ranging between 56.6% and 87.9%. The highest LoC has been found in the area of clinical services (83.7% for imaging and 87.9% for therapy), whereas the lowest levels have been found for Radiopharmacy Level 2 (56.6%); Computer Systems and Data Handling (66.6%); and Evaluation of the Quality Management System (67.6%). Prioritization of non-conformances produced a total of 1687 recommendations in the final audit report. Depending on the impact on safety and daily clinical activities, they were further classified as critical (requiring immediate action; n = 276; 16% of the total); major (requiring action in relatively short time, typically from 3 to 6 months; n = 604; 36%); whereas the remaining 807 (48%) were classified as minor, that is, to be addressed whenever possible. The greatest proportion of recommendations has been found in the category "Managerial, Organization and Documentation" (26%); "Staff Radiation Protection and Safety" (17.3%); "Radiopharmaceuticals Preparation, Dispensing and Handling" (15.8%); and "Quality Assurance/Quality Control" and "Management of Equipment and Software" (11.4%). The lowest level of recommendations belongs to the item "Human Resources" (4%). The QUANUM program proved applicable to a wide variety of institutions, from small practices to larger centers with PET/CT and cyclotrons. Clinical services rendered to patients showed a good compliance with international standards, whereas issues related to radiation protection of both staff and patients will require a higher degree of attention. This is a relevant feedback for the International Atomic Energy Agency with regard to the effective translation of safety recommendations into routine practice. Training on drafting and application of standard operating procedures should also be considered a priority

    Comprehensive Auditing in Nuclear Medicine Through the International Atomic Energy Agency Quality Management Audits in Nuclear Medicine (QUANUM) Program. Part 1: the QUANUM Program and Methodology.

    No full text
    An effective management system that integrates quality management is essential for a modern nuclear medicine practice. The Nuclear Medicine and Diagnostic Imaging Section of the International Atomic Energy Agency (IAEA) has the mission of supporting nuclear medicine practice in low- and middle-income countries and of helping them introduce it in their health-care system, when not yet present. The experience gathered over several years has shown diversified levels of development and varying degrees of quality of practice, among others because of limited professional networking and limited or no opportunities for exchange of experiences. Those findings triggered the development of a program named Quality Management Audits in Nuclear Medicine (QUANUM), aimed at improving the standards of NM practice in low- and middle-income countries to internationally accepted standards through the introduction of a culture of quality management and systematic auditing programs. QUANUM takes into account the diversity of nuclear medicine services around the world and multidisciplinary contributions to the practice. Those contributions include clinical, technical, radiopharmaceutical, and medical physics procedures. Aspects of radiation safety and patient protection are also integral to the process. Such an approach ensures consistency in providing safe services of superior quality to patients. The level of conformance is assessed using standards based on publications of the IAEA and the International Commission on Radiological Protection, and guidelines from scientific societies such as Society of Nuclear Medicine and Molecular Imaging (SNMMI) and European Association of Nuclear Medicine (EANM). Following QUANUM guidelines and by means of a specific assessment tool developed by the IAEA, auditors, both internal and external, will be able to evaluate the level of conformance. Nonconformances will then be prioritized and recommendations will be provided during an exit briefing. The same tool could then be applied to assess any improvement after corrective actions are taken. This is the first comprehensive audit program in nuclear medicine that helps evaluate managerial aspects, safety of patients and workers, clinical practice, and radiopharmacy, and, above all, keeps them under control all together, with the intention of continuous improvement

    Development of methodologies for dimethylaminoethanol glycolate assay in association with sunscreens in dermocosmetic formulation

    Get PDF
    DMAE glycolate (DG) and sunscreens have been used associated in anti-aging dermocosmetic formulations. Despite extensive use of these substances, methods for quantification of DG as raw material and in cosmetic formulations, especially when associated, are not described in the literature. RP-HPLC and non-aqueous titration methods, with determination potentiometric end-point (PT), were developed and validated for rapid assay of DG as raw material and in a topic emulsion in association with sunscreens. Both methods are simple, selective, linear, accurate and precise. The PT method was chosen for stability study of DG in the formulation developed. The proposed formulation presented good stability performance as regards aspect, pH, apparent viscosity, and SPF, with less than 5% of DG degradation compared to initial conditions.<br>Glicolato de DMAE (DG) e protetores solares tĂȘm sido utilizados associados em formulaçÔes dermocosmĂ©ticas antiidade. Apesar da ampla utilização dessas substĂąncias, mĂ©todos de quantificação para DG matĂ©ria-prima e em formulaçÔes cosmĂ©ticas, especialmente quando associados, nĂŁo estĂŁo descritos na literatura. Neste trabalho foram desenvolvidas e validadas metodologias por CLAE-FR e titulação em meio nĂŁo-aquoso, com determinação do ponto final por potenciomĂ©trica (TP), para a rĂĄpida anĂĄlise de DG matĂ©ria-prima e em emulsĂŁo tĂłpica em associação com fotoprotetores. Ambos os mĂ©todos sĂŁo simples, seletivos, lineares, exatos e precisos. O mĂ©todo TP foi escolhido para o estudo da estabilidade do DG na formulação desenvolvida. A formulação proposta apresentou um bom desempenho no que se refere a estabilidade, aspecto, pH, viscosidade aparente e SPF, com menos de 5% degradação do DG comparado as condiçÔes iniciais
    corecore