2,960 research outputs found

    The bicomplex quantum Coulomb potential problem

    Full text link
    Generalizations of the complex number system underlying the mathematical formulation of quantum mechanics have been known for some time, but the use of the commutative ring of bicomplex numbers for that purpose is relatively new. This paper provides an analytical solution of the quantum Coulomb potential problem formulated in terms of bicomplex numbers. We define the problem by introducing a bicomplex hamiltonian operator and extending the canonical commutation relations to the form [X_i,P_k] = i_1 hbar xi delta_{ik}, where xi is a bicomplex number. Following Pauli's algebraic method, we find the eigenvalues of the bicomplex hamiltonian. These eigenvalues are also obtained, along with appropriate eigenfunctions, by solving the extension of Schrodinger's time-independent differential equation. Examples of solutions are displayed. There is an orthonormal system of solutions that belongs to a bicomplex Hilbert space.Comment: Clarifications; some figures removed; version to appear in Can. J. Phy

    Inflammatory Airway Disease of Horses - Revised Consensus Statement

    Get PDF
    The purpose of this manuscript is to revise and update the previous consensus statement on inflammatory airway disease (IAD) in horses. Since 2007, a large number of scientific articles have been published on the topic and these new findings have led to a significant evolution of our understanding of IAD

    Gating NO Release from Nitric Oxide Synthase

    Get PDF
    We have investigated the kinetics of NO escape from Geobacillus stearothermophilus nitric oxide synthase (gsNOS). Previous work indicated that NO release was gated at position 223 in mammalian enzymes; our kinetics experiments include mutants at that position along with measurements on the wild type enzyme. Employing stopped-flow UV–vis methods, reactions were triggered by mixing a reduced enzyme/N-hydroxy-l-arginine complex with an aerated buffer solution. NO release kinetics were obtained for wt NOS and three mutants (H134S, I223V, H134S/I223V). We have confirmed that wt gsNOS has the lowest NO release rate of known NOS enzymes, whether bacterial or mammalian. We also have found that steric clashes at positions 223 and 134 hinder NO escape, as judged by enhanced rates in the single mutants. The empirical rate of NO release from the gsNOS double mutant (H134/I223V) is nearly as rapid as that of the fastest mammalian enzymes, demonstrating that both positions 223 and 134 function as gates for escape of the product diatomic molecule

    Phase formation and thermal stability of ultrathin nickel-silicides on Si(100)

    Get PDF
    The solid-state reaction and agglomeration of thin nickel-silicide films was investigated from sputter deposited nickel films (1-10 nm) on silicon-on-insulator (100) substrates. For typical anneals at a ramp rate of 3 degrees C/s, 5-10 nm Ni films react with silicon and form NiSi, which agglomerates at 550-650 degrees C, whereas films with a thickness of 3.7 nm of less were found to form an epitaxylike nickel-silicide layer. The resulting films show an increased thermal stability with a low electrical resistivity up to 800 degrees C

    The effects of antioxidant vitamin supplementation on resistance exercise induced lipid peroxidation in trained and untrained participants

    Get PDF
    BACKGROUND: The theoretical benefits of using antioxidant vitamin supplements to quench oxygen free radicals appear large. High intensity aerobic-type exercise produces oxygen free radicals that can cause damage to lipid membranes (lipid peroxidation) that may lead to many problems such as the inactivation of cell membrane enzymes, the progression of degenerative diseases (cardiovascular disease and cancer) and lessening of the effectiveness of the immune system. The major function of vitamin E is to work as a chain-breaking antioxidant in a fat soluble environment. Little research has examined lipid peroxidation associated with high intensity resistance exercise or possible protective effects of antioxidant supplementation or the effects of training state. RESULTS: There were no significant group (trained vs untrained) or treatment (vitamin E vs placebo) effects found between the 4 groups assessed. There was only one significant difference found and that was in the main effect for time (F = 22.41, p < 0.01). CONCLUSIONS: The Resistance Exercise Test caused a significant increase in malondialdehyde in all 4 groups at 6 hours post exercise. There was no evidence that vitamin E supplementation was effective in reducing oxidative damage in comparison to the placebo group. As well, there was no difference between the trained and untrained groups with respect to their impact on lipid peroxidation measures

    Test fixture for determination of energy absorbing capabilities of composite materials

    Get PDF
    The present invention provides a fixture for supporting an elongated specimen for crush testing. The fixture comprises a base plate, four guiding rods, a sliding plate, four support rods and two collars. The guiding rods connect to the base plate and extend in a direction substantially perpendicular to the base plate. The sliding plate has linear bearings which encircle the guiding rods and enable translation of the sliding plate along the axis of each guiding rod. The four supporting rods mount to the base plate and also extend in a direction substantially perpendicular to the base plate. Each support rod has a keyway for a wedge which contacts the elongated specimen and holds the specimen in place during crushing. Each collar lies above the sliding plate and holds a pair of support rods on their ends opposite the ends connected to the base plate. A spherical bearing sits on top of the sliding plate and transfers an applied load to the sliding plate, which moves downward and crushes the elongated specimen

    Test Fixture for Determination of Energy Absorbing Capabilities of Composite Materials

    Get PDF
    The present invention provides a fixture for supporting an elongated specimen for crush testing. The fixture comprises a base plate. four guiding rods, a sliding plate, four support rods and two collars. The guiding rods connect to the base plate and extend in a direction substantially perpendicular to the base plate. The sliding plate has linear bearings which encircle the guiding rods and enable translation of the sliding plate along the axis of each guiding rod. The four supporting rods mount to the base plate and also extend in a direction substantially perpendicular to the base plate. Each support rod has a keyway for a wedge which contacts the elongated specimen and holds the specimen in place during crushing. Each collar lies above the sliding plate and holds a pair of support rods on their ends opposite the ends connected to the base plate. A spherical bearing sits on top of the sliding plate and transfers an applied load to the sliding plate, which moves downward and crushes the elongated specimen

    Cognitive-behaviour therapy and skilled motor performance in adults with chronic tic disorder

    Get PDF
    The first aim of the present study was to compare performance of people with tic disorders (TD) and controls on executive function and a range of skilled motor tests requiring complex performance, guided movements, hand co-ordination, and fine control of steadiness. The second aim was to investigate the effect of cognitive behaviour therapy (CBT) on motor performance. A total of 55 patients with TD were recruited at baseline from participants in a behavioural management programme. A comparison group of 55 patients suffering from a variety of habit disorders (HD) involving complex manual movements, were matched on age and level of education to 34 non-psychiatric controls. Participants were evaluated pre- and post-treatment and post-waitlist with a neuropsychological evaluation focusing on executive function (Wisconsin Card Sorting Test, WCST) and skilled motor performance (Purdue Pegboard, Hole Steadiness Test, and the Groove Test). Results revealed WCST scores in the normal range, while motor performance differed significantly on the Purdue Pegboard Tests in both TD and HD as compared to the control group. Cognitive-behavioural treatment selectively improved motor performance in both clinical groups compared to waitlist control, and this improvement related to clinical outcome measures

    The buffering power of overt socially supportive and unsupportive behaviors from the significant other on posttraumatic stress disorder individuals’ emotional state

    Full text link
    Social support is one of the three strongest predictors of posttraumatic stress disorder (PTSD). In the present study, we aimed to assess the buffering power of overt socially supportive and unsupportive behaviors from the significant other, in a group with PTSD and a comparison group. Design and methods: A total of 46 individuals with PTSD and 42 individuals with obsessive-compulsive disorder (OCD) or panic disorder (PD) completed diagnostic interviews and an anxiety-oriented social interaction with a significant other. Heart rate of participants was continuously measured during this interaction and overt social behaviors from the significant other were recorded on videotape and coded using a validated system. Results: Changes in heart rate in PTSD participants correlated negatively with changes in overt socially supportive behaviors from their significant other (r from −.36 to −.50, p  .05). No such statistically significant association emerged in the group with OCD or PD (r from .01 to −.27, p > .05). Conclusions: This study sustain the buffering power of overt supportive behaviors from the significant other on heart rate changes in PTSD
    • 

    corecore