92 research outputs found
Synthetic IRIS spectra of the solar transition region: Effect of high-energy tails
The solar transition region satisfies the conditions for presence of
non-Maxwellian electron energy distributions with high-energy tails at energies
corresponding to the ionization potentials of many ions emitting in the EUV and
UV portions of the spectrum. We calculate the synthetic Si IV, O IV, and S IV
spectra in the far ultra-violet (FUV) channel of the Interface Region Imaging
Spectrograph (IRIS). Ionization, recombination, and excitation rates are
obtained by integration of the cross-sections or their approximations over the
model electron distributions considering particle propagation from the hotter
corona. The ionization rates are significantly affected by the presence of
high-energy tails. This leads to the peaks of the relative abundance of
individual ions to be broadened with pronounced low-temperature shoulders. As a
result, the contribution functions of individual lines observable by IRIS also
exhibit low-temperature shoulders, or their peaks are shifted to temperatures
an order of magnitude lower than for the Maxwellian distribution. The
integrated emergent spectra can show enhancements of Si IV compared toO IV by
more than a factor of two. The high-energy particles can have significant
impact on the emergent spectra and their presence needs to be considered even
in situations without strong local acceleration
A statistical analysis of cervical auscultation signals from adults with unsafe airway protection
Background: Aspiration, where food or liquid is allowed to enter the larynx during a swallow, is recognized as the most clinically salient feature of oropharyngeal dysphagia. This event can lead to short-term harm via airway obstruction or more long-term effects such as pneumonia. In order to non-invasively identify this event using high resolution cervical auscultation there is a need to characterize cervical auscultation signals from subjects with dysphagia who aspirate. Methods: In this study, we collected swallowing sound and vibration data from 76 adults (50 men, 26 women, mean age 62) who underwent a routine videofluoroscopy swallowing examination. The analysis was limited to swallows of liquid with either thin (<5 cps) or viscous (≈300 cps) consistency and was divided into those with deep laryngeal penetration or aspiration (unsafe airway protection), and those with either shallow or no laryngeal penetration (safe airway protection), using a standardized scale. After calculating a selection of time, frequency, and time-frequency features for each swallow, the safe and unsafe categories were compared using Wilcoxon rank-sum statistical tests. Results: Our analysis found that few of our chosen features varied in magnitude between safe and unsafe swallows with thin swallows demonstrating no statistical variation. We also supported our past findings with regard to the effects of sex and the presence or absence of stroke on cervical ausculation signals, but noticed certain discrepancies with regards to bolus viscosity. Conclusions: Overall, our results support the necessity of using multiple statistical features concurrently to identify laryngeal penetration of swallowed boluses in future work with high resolution cervical auscultation
Signatures of the non-Maxwellian -distributions in optically thin line spectra. II. Synthetic Fe XVII--XVIII X-ray coronal spectra and predictions for the Marshall Grazing-Incidence X-ray Spectrometer (MaGIXS)
We investigated the possibility of diagnosing the degree of departure from
the Maxwellian distribution using the Fe XVII - Fe XVIII spectra originating in
plasmas in collisional ionization equilibrium, such as in the cores of solar
active regions or microflares. The original collision strengths for excitation
are integrated over the non-Maxwellian electron -distributions
characterized by a high-energy tail. Synthetic X-ray emission line spectra were
calculated for a range of temperatures and . We focus on the 6-24 A
spectral range to be observed by the upcoming Marshall Grazing-Incidence X-ray
Spectrometer MaGIXS. We find that many line intensity ratios are sensitive to
both and . Best diagnostic options are provided if a ratio
involving both Fe XVII and Fe XVIII is combined with another ratio involving
lines formed within a single ion. The sensitivity of such diagnostics to
is typically a few tens of per cent. Much larger sensitivity, of about
a factor of two to three, can be obtained if the Fe XVIII 93.93 A line observed
by SDO/AIA is used in conjuction with the X-ray lines. We conclude that the
MaGIXS instrument is well-suited for detection of departures from the
Maxwellian distribution, especially in active region cores.Comment: Astronomy & Astrophysics, accepte
Mid-Infrared Properties of the Swift Burst Alert Telescope Active Galactic Nuclei Sample of the Local Universe. I. Emission-Line Diagnostics
We compare mid-infrared emission-line properties, from high-resolution
Spitzer spectra of a hard X-ray (14 -- 195 keV) selected sample of nearby (z <
0.05) AGN detected by the Burst Alert Telescope (BAT) aboard Swift. The
luminosity distribution for the mid-infrared emission-lines, [O IV] 25.89
micron, [Ne II] 12.81 micron, [Ne III] 15.56 micron and [Ne V] 14.32/24.32
micron, and hard X-ray continuum show no differences between Seyfert 1 and
Seyfert 2 populations, however six newly discovered BAT AGNs are under-luminous
in [O IV], most likely the result of dust extinction in the host galaxy. The
overall tightness of the mid-infrared correlations and BAT fluxes and
luminosities suggests that the emission lines primarily arise in gas ionized by
the AGN. We also compare the mid-infrared emission-lines in the BAT AGNs with
those from published studies of ULIRGs, PG QSOs, star-forming galaxies and
LINERs. We find that the BAT AGN sample fall into a distinctive region when
comparing the [Ne III]/[Ne II] and the [O IV]/[Ne III] ratios. These line
ratios are lower in sources that have been previously classified in the
mid-infrared/optical as AGN than those found for the BAT AGN, suggesting that,
in our X-ray selected sample, the AGN represents the main contribution to the
observed line emission. These ratios represent a new emission line diagnostic
for distinguishing between AGN and star forming galaxies.Comment: 54 pages, 9 Figures. Accepted for publication in The Astrophysical
Journal
PENERAPAN PERATURAN PEMERINTAH NOMOR 140 TAHUN 2000 ATAS KONTRAK JANGKA PANJANG PADA PT. “X” SEMARANG
TIDAK TERSEDI
The effects of increased fluid viscosity on swallowing sounds in healthy adults
Background: Cervical auscultation (CA) is an affordable, non-invasive technique used to observe sounds occurring during swallowing. CA involves swallowing characterization via stethoscopes or microphones, while accelerometers can detect other vibratory signals. While the effects of fluid viscosity on swallowing accelerometry signals is well understood, there are still open questions about these effects on swallowing sounds. Therefore, this study investigated the influence of fluids with increasing thickness on swallowing sound characteristics.Method: We collected swallowing sounds and swallowing accelerometry signals from 56 healthy participants. Each participant completed five water swallows, five swallows of nectar-thick apple juice, and five swallows of honey-thick apple juice. These swallows were completed in neutral head and chin-tuck head positions. After pre-processing of collected signals, a number of features in time, frequency and time-frequency domains were extracted.Results: Our numerical analysis demonstrated that significant influence of viscosity was found in most of the features. In general, features extracted from swallows in the neutral head position were affected more than swallows from the chin-tuck position. Furthermore, most of the differences were found between water and fluids with higher viscosity. Almost no significant differences were found between swallows involving nectar-thick and honey-thick apple juices. Our results also showed that thicker fluids had higher acoustic regularity and predictability as demonstrated by the information-theoretic features, and a lower frequency content as demonstrated by features in the frequency domain.Conclusions: According to these results, we can conclude that viscosity of fluids should be considered in future investigations involving swallowing sounds. © 2013 Jestrovićet al.; licensee BioMed Central Ltd
A comparative analysis of swallowing accelerometry and sounds during saliva swallows
Background: Accelerometry (the measurement of vibrations) and auscultation (the measurement of sounds) are both non-invasive techniques that have been explored for their potential to detect abnormalities in swallowing. The differences between these techniques and the information they capture about swallowing have not previously been explored in a direct comparison. Methods: In this study, we investigated the differences between dual-axis swallowing accelerometry and swallowing sounds by recording data from adult participants and calculating a number of time and frequency domain features. During the experiment, 55 participants (ages 18-65) were asked to complete five saliva swallows in a neutral head position. The resulting data was processed using previously designed techniques including wavelet denoising, spline filtering, and fuzzy means segmentation. The pre-processed signals were then used to calculate 9 time, frequency, and time-frequency domain features for each independent signal. Wilcoxon signed-rank and Wilcoxon rank-sum tests were utilized to compare feature values across transducers and patient demographics, respectively. Results: In addition to finding a number of features that varied between male and female participants, our statistical analysis determined that the majority of our chosen features were statistically significantly different across the two sensor methods and that the dependence on within-subject factors varied with the transducer type. However, a regression analysis showed that age accounted for an insignificant amount of variation in our signals. Conclusions: We conclude that swallowing accelerometry and swallowing sounds provide different information about deglutition despite utilizing similar transduction methods. This contradicts past assumptions in the field and necessitates the development of separate analysis and processing techniques for swallowing sounds and vibrations
- …