    Heterogeneous strain distribution in the subchondral bone of human osteoarthritic femoral heads, measured with digital volume correlation

    Get PDF
    Osteoarthritis (OA) is a chronic disease, affecting approximately one third of people over the age of 45. Whilst the etiology and pathogenesis of the disease are still not well understood, mechanics play an important role in both the initiation and progression of osteoarthritis. In this study, we demonstrate the application of stepwise compression, combined with microCT imaging and digital volume correlation (DVC) to measure and evaluate full-field strain distributions within osteoarthritic femoral heads under uniaxial compression. A comprehensive analysis showed that the microstructural features inherent in OA bone did not affect the level of uncertainties associated with the applied methods. The results illustrate the localization of strains at the loading surface as well as in areas of low bone volume fraction and subchondral cysts. Trabecular thickness and connectivity density were identified as the only microstructural parameters with any association to the magnitude of local strain measured at apparent yield strain or the volume of bone exceeding yield strain. This work demonstrates a novel approach to evaluating the mechanical properties of the whole human femoral head in case of severe OA

    Performance of QCT-Derived scapula finite element models in predicting local displacements using digital volume correlation

    Get PDF
    Subject-specific finite element models (FEMs) of the shoulder complex are commonly used to predict differences in internal load distribution due to injury, treatment or disease. However, these models rely on various underlying assumptions, and although experimental validation is warranted, it is difficult to obtain and often not performed. The goal of the current study was to quantify the accuracy of local displacements predicted by subject-specific QCT-based FEMs of the scapula, compared to experimental measurements obtained by combining digital volume correlation (DVC) and mechanical loading of cadaveric specimens within a microCT scanner. Four cadaveric specimens were loaded within a microCT scanner using a custom-designed six degree-of-freedom hexapod robot augmented with carbon fiber struts for radiolucency. BoneDVC software was used to quantify full-field experimental displacements between pre- and post-loaded scans. Corresponding scapula QCT-FEMs were generated and three types of boundary conditions (BC) (idealized-displacement, idealized-force, and DVC-derived) were simulated for each specimen. DVC-derived BCs resulted in the closest match to the experimental results for all specimens (best agreement: slope ranging from 0.87 to 1.09; highest correlation: r2 ranging from 0.79 to 1.00). In addition, a two orders of magnitude decrease was observed in root-mean-square error when using QCT-FEMs with simulated DVC-derived BCs compared to idealized-displacement and idealized-force BCs. The results of this study demonstrate that scapula QCT-FEMs can accurately predict local experimental full-field displacements if the BCs are derived from DVC measurements

    Analysis of Bone Architecture in Rodents Using Micro-Computed Tomography.

    Get PDF
    This chapter describes the use of micro-computed tomography scanning for analyzing bone structure, focussing on rodent bone. It discusses sample preparation, the correct setup of the scanner, the impact of some of the important scanner settings and new applications

    Material mapping of QCT-derived scapular models : a comparison with micro-CT loaded specimens using digital volume correlation

    Get PDF
    Subject- and site-specific modeling techniques greatly improve finite element models (FEMs) derived from clinical-resolution CT data. A variety of density-modulus relationships are used in scapula FEMs, but the sensitivity to selection of relationships has yet to be experimentally evaluated. The objectives of this study were to compare quantitative-CT (QCT) derived FEMs mapped with different density-modulus relationships and material mapping strategies to experimentally loaded cadaveric scapular specimens. Six specimens were loaded within a micro-CT (33.5 μm isotropic voxels) using a custom-hexapod loading device. Digital volume correlation (DVC) was used to estimate full-field displacements by registering images in pre- and post-loaded states. Experimental loads were measured using a 6-DOF load cell. QCT-FEMs replicated the experimental setup using DVC-driven boundary conditions (BCs) and were mapped with one of fifteen density-modulus relationships using elemental or nodal material mapping strategies. Models were compared based on predicted QCT-FEM nodal reaction forces compared to experimental load cell measurements and linear regression of the full-field nodal displacements compared to the DVC full-field displacements. Comparing full-field displacements, linear regression showed slopes ranging from 0.86 to 1.06, r-squared values of 0.82–1.00, and max errors of 0.039 mm for all three Cartesian directions. Nearly identical linear regression results occurred for both elemental and nodal material mapping strategies. Comparing QCT-FEM to experimental reaction forces, errors ranged from − 46 to 965% for all specimens, with specimen-specific errors as low as 3%. This study utilized volumetric imaging combined with mechanical loading to derive full-field experimental measurements to evaluate various density-modulus relationships required for QCT-FEMs applied to whole-bone scapular loading. The results suggest that elemental and nodal material mapping strategies are both able to simultaneously replicate experimental full-field displacements and reactions forces dependent on the density-modulus relationship used

    Precision of Digital Volume Correlation Approaches for Strain Analysis in Bone Imaged with Micro-Computed Tomography at Different Dimensional Levels

    Get PDF
    Accurate measurement of local strain in heterogeneous and anisotropic bone tissue is fundamental to understand the pathophysiology of musculoskeletal diseases, to evaluate the effect of interventions from preclinical studies, and to optimize the design and delivery of biomaterials. Digital volume correlation (DVC) can be used to measure the three-dimensional displacement and strain fields from micro-computed tomography (μCT) images of loaded specimens. However, this approach is affected by the quality of the input images, by the morphology and density of the tissue under investigation, by the correlation scheme, and by the operational parameters used in the computation. Therefore, for each application, the precision of the method should be evaluated. In this paper, we present the results collected from datasets analyzed in previous studies as well as new data from a recent experimental campaign for characterizing the relationship between the precision of two different DVC approaches and the spatial resolution of the outputs. Different bone structures scanned with laboratory source μCT or synchrotron light μCT (SRμCT) were processed in zero-strain tests to evaluate the precision of the DVC methods as a function of the subvolume size that ranged from 8 to 2,500 µm. The results confirmed that for every microstructure the precision of DVC improves for larger subvolume size, following power laws. However, for the first time, large differences in the precision of both local and global DVC approaches have been highlighted when SRμCT or in vivo μCT images were used instead of conventional ex vivo μCT. These findings suggest that in situ mechanical testing protocols applied in SRμCT facilities should be optimized to allow DVC analyses of localized strain measurements. Moreover, for in vivo μCT applications, DVC analyses should be performed only with relatively course spatial resolution for achieving a reasonable precision of the method. In conclusion, we have extensively shown that the precision of both tested DVC approaches is affected by different bone structures, different input image resolution, and different subvolume sizes. Before each specific application, DVC users should always apply a similar approach to find the best compromise between precision and spatial resolution of the measurements