1,148 research outputs found

    Coherent Exciton Lasing in ZnSe/ZnCdSe Quantum Wells?

    Full text link
    A new mechanism for exciton lasing in ZnSe/ZnCdSe quantum wells is proposed. Lasing, occurring below the lowest exciton line, may be associated with a BCS-like condensed (coherent) exciton state. This state is most stable at low temperatures for densities in the transition region separating the exciton Bose gas and the coherent exciton state. Calculations show the gain region to lie below the exciton line and to be separated from the absorption regime by a transparency region of width, for example, about 80 meV for a 90 Angstrom ZnSe/Zn_(0.75)Cd_(0.25)Se quantum well. Experimental observation of the transparency region using differential spectroscopy would confirm this picture.Comment: 9 pages + 3 figs contained in 4 postscript files to appear Appl. Phys. Lett. March 13, 199

    Discovery of Bragg confined hybrid modes with high Q-factor in a hollow dielectric resonator

    Full text link
    The authors report on observation of Bragg confined mode in a hollow cylindrical dielectric cavity. A resonance was observed at 13.4 GHzGHz with an unloaded Q-factor of order 2×1052\times10^5, which is more than a factor of 6 above the dielectric loss limit. Previously such modes have only been realized from pure Transverse Electric modes with no azimuthal variations and only the EϕE_{\phi} component. From rigorous numeric simulations it is shown that the mode is a hybrid mode with non-zero azimuthal variations and with dominant ErE_r and EϕE_{\phi} electric field components and HzH_z magnetic field component.Comment: Accepted to be published in Applied Physics Letter

    Geodetic, teleseismic, and strong motion constraints on slip from recent southern Peru subduction zone earthquakes

    Get PDF
    We use seismic and geodetic data both jointly and separately to constrain coseismic slip from the 12 November 1996 M_w 7.7 and 23 June 2001 M_w 8.5 southern Peru subduction zone earthquakes, as well as two large aftershocks following the 2001 earthquake on 26 June and 7 July 2001. We use all available data in our inversions: GPS, interferometric synthetic aperture radar (InSAR) from the ERS-1, ERS-2, JERS, and RADARSAT-1 satellites, and seismic data from teleseismic and strong motion stations. Our two-dimensional slip models derived from only teleseismic body waves from South American subduction zone earthquakes with M_w > 7.5 do not reliably predict available geodetic data. In particular, we find significant differences in the distribution of slip for the 2001 earthquake from models that use only seismic (teleseismic and two strong motion stations) or geodetic (InSAR and GPS) data. The differences might be related to postseismic deformation or, more likely, the different sensitivities of the teleseismic and geodetic data to coseismic rupture properties. The earthquakes studied here follow the pattern of earthquake directivity along the coast of western South America, north of 5°S, earthquakes rupture to the north; south of about 12°S, directivity is southerly; and in between, earthquakes are bilateral. The predicted deformation at the Arequipa GPS station from the seismic-only slip model for the 7 July 2001 aftershock is not consistent with significant preseismic motion

    The Crab pulsar light curve in the soft gamma ray range: FIGARO II results

    Get PDF
    The FIGARO II experiment (a large area, balloon borne, crystal scintillator detector working from 0.15 to 4.3 MeV) observed the Crab pulsar on 1990 Jul. 9 for about seven hours. The study of the pulse profile confirms some structures detected with a low significance during the shorter observation of 1986, and adds new important elements to the picture. In particular, between the two main peaks, two secondary peaks appear centered at phase values 0.1 and 0.3, in the energy range 0.38 to 0.49 MeV; in the same energy range, a spectral feature at 0.44 MeV, interpreted as a redshifted positron annihilation line, was observed during the same balloon flight in the phase interval including the second main peak and the neighboring secondary peak. If the phase interval considered is extended to include also the other secondary peak, the significance of the spectral line appears to increase

    IC 225: a dwarf elliptical galaxy with a peculiar blue core

    Full text link
    We present the discovery of a peculiar blue core in the elliptical galaxy IC 225 by using images and spectrum from the Sloan Digital Sky Survey (SDSS). The outer parts of the surface brightness profiles of u-, g-, r-, i- and z-band SDSS images for IC 225 are well fitted with an exponential function. The fitting results show that IC 225 follows the same relations between the magnitude, scale length and central surface brightness for dwarf elliptical galaxies. Its absolute blue magnitude (M_B) is -17.14 mag, all of which suggest that IC 225 is a typical dwarf elliptical galaxy. The g-r color profile indicates a very blue core with a radius of 2 arcseconds, which is also clearly seen in the RGB image made of g-, r- and i-band SDSS images. The SDSS optical spectrum exhibits strong and very narrow nebular emission lines. The metal abundances derived by the standard methods, which are 12+log(O/H) = 8.98, log(N/O) = -0.77 and 12+log(S+/H+) = 6.76, turn out to be significantly higher than that predicted by the well-known luminosity-metallicity relation. After carefully inspecting the central region of IC 225, we find that there are two distinct nuclei, separated by 1.4 arcseconds, the off-nucleated one is even bluer than the nucleus of IC 225. The asymmetric line profiles of higher-order Balmer lines indicate that the emission lines are bluer shifted relative to the absorption lines, suggesting that the line emission arises from the off-center core, whose nature is a metal-rich Hii region. To the best of our knowledge, it is the first high-metallicity Hii region detected in a dwarf elliptical galaxy.Comment: 7 figures, accepted for publication in A

    Effects of density imbalance on the BCS-BEC crossover in semiconductor electron-hole bilayers

    Full text link
    We study the occurrence of excitonic superfluidity in electron-hole bilayers at zero temperature. We not only identify the crossover in the phase diagram from the BCS limit of overlapping pairs to the BEC limit of non-overlapping tightly-bound pairs but also, by varying the electron and hole densities independently, we can analyze a number of phases that occur mainly in the crossover region. With different electron and hole effective masses, the phase diagram is asymmetric with respect to excess electron or hole densities. We propose as the criterion for the onset of superfluidity, the jump of the electron and hole chemical potentials when their densities cross.Comment: 4 pages, 3 figure

    Touch DNA collection - Performance of four different swabs.

    Get PDF
    A collaborative study conducted by three police forensic units, a DNA laboratory, and a forensic academic institute was undertaken in order to compare the performance of four different swabs in controlled and quasi-operational conditions. For this purpose, a reference swab (Prionics cardboard evidence collection kit) currently used within the police forensic units and 3 challenger swabs (COPAN 4N6FLOQSwabs™ (Genetics variety), Puritan FAB-MINI-AP and Sarstedt Forensic Swab) were used for collecting DNA traces from previously used items (referred as "touch DNA" in this article) including on 60 collars, 60 screwdrivers and 60 steering wheels obtained from volunteers. For each comparison, the surface considered was divided into two equal components; one was sampled with the reference swab and the other with one of the three challenger swabs. This lead to a total of 360 samples. Conclusions were consistent within the four operational partners. From a practical point of view, the COPAN 4N6FLOQSwabs™ (Genetics variety) was judged the most convenient to use. Furthermore, it allowed the recovery of significantly more DNA from collars (0.65 vs 0.13 ng/μL) and steering wheels (2.82 vs 1.77 ng/μL), and a similar amount of DNA from screwdrivers (0.032 vs 0.026 ng/μL) compared with the Prionics reference swab. The two other challenger swabs provided results that were not significantly different from the reference swab, except for the Puritan swab, whose performance was significantly lower for steering wheels (0.37 vs 0.58 ng/μL). As part of a conservation study, 50 μL of a blood dilution (1/4 with PBS) was deposited on a total of 105 COPAN (Genetics and Crime Scene varieties), Prionics and Sarstedt swabs. They were stored within a cupboard at room temperature. The integrity of the recovered DNA was evaluated with NGM SElect™ DNA profiles after different time-spans ranging from 1 day to 12 months by comparing the height difference of the peaks occurring at the shortest and longest loci, respectively. DNA seemed to remain stable, except when using the COPAN 4N6FLOQSwabs™ treated with an antimicrobial agent (Crime scene variety), which resulted in significant DNA degradation. Following these tests, the COPAN 4N6FLOQSwabs™ (Genetics variety), a model with a desiccant, was selected for further testing in fully operational conditions

    Numerical studies towards practical large-eddy simulation

    Get PDF
    Large-eddy simulation developments and validations are presented for an improved simulation of turbulent internal flows. Numerical methods are proposed according to two competing criteria: numerical qualities (precision and spectral characteristics), and adaptability to complex configurations. First, methods are tested on academic test-cases, in order to abridge with fundamental studies. Consistent results are obtained using adaptable finite volume method, with higher order advection fluxes, implicit grid filtering and "low-cost" shear-improved Smagorinsky model. This analysis particularly focuses on mean flow, fluctuations, two-point correlations and spectra. Moreover, it is shown that exponential averaging is a promising tool for LES implementation in complex geometry with deterministic unsteadiness. Finally, adaptability of the method is demonstrated by application to a configuration representative of blade-tip clearance flow in a turbomachine
    corecore