14 research outputs found

    Exposure modelling in Europe : how to pave the road for the future as part of the European Exposure Science Strategy 2020-2030

    Get PDF
    Exposure models are essential in almost all relevant contexts for exposure science. To address the numerous challenges and gaps that exist, exposure modelling is one of the priority areas of the European Exposure Science Strategy developed by the European Chapter of the International Society of Exposure Science (ISES Europe). A strategy was developed for the priority area of exposure modelling in Europe with four strategic objectives. These objectives are (1) improvement of models and tools, (2) development of new methodologies and support for understudied fields, (3) improvement of model use and (4) regulatory needs for modelling. In a bottom-up approach, exposure modellers from different European countries and institutions who are active in the fields of occupational, population and environmental exposure science pooled their expertise under the umbrella of the ISES Europe Working Group on exposure models. This working group assessed the state-of-the-art of exposure modelling in Europe by developing an inventory of exposure models used in Europe and reviewing the existing literature on pitfalls for exposure modelling, in order to identify crucial modelling-related strategy elements. Decisive actions were defined for ISES Europe stakeholders, including collecting available models and accompanying information in a living document curated and published by ISES Europe, as well as a long-term goal of developing a best-practices handbook. Alongside these actions, recommendations were developed and addressed to stakeholders outside of ISES Europe. Four strategic objectives were identified with an associated action plan and roadmap for the implementation of the European Exposure Science Strategy for exposure modelling. This strategic plan will foster a common understanding of modelling-related methodology, terminology and future research in Europe, and have a broader impact on strategic considerations globally.Peer reviewe

    The probabilistic aggregate consumer exposure model (PACEM): Validation and comparison to a lower-tier assessment for the cyclic siloxane D5

    Get PDF
    a b s t r a c t a r t i c l e i n f o Current practice of chemical risk assessment for consumer product ingredients still rarely exercises the aggregation of multi-source exposure. However, focusing on a single dominant source/pathway combination may lead to a significant underestimation of the risk for substances present in numerous consumer products, which often are used simultaneously. Moreover, in most cases complex multi-route exposure scenarios also need to be accounted for. This paper introduces and evaluates the performance of the Probabilistic Aggregate Consumer Exposure Model (PACEM) applied in the context of a tiered approach to exposure assessment for ingredients in cosmetics and personal care products (C&PCPs) using decamethylcyclopentasiloxane (D5) as a worked example. It is demonstrated that PACEM predicts a more realistic, but still conservative aggregate exposure within the Dutch adult population when compared to a deterministic point estimate obtained in a lower tier screening assessment. An overall validation of PACEM is performed by quantitatively relating and comparing its estimates to currently available human biomonitoring and environmental sampling data. Moderate (by maximum one order of magnitude) overestimation of exposure is observed due to a justified conservatism built into the model structure, resulting in the tool being suitable for risk assessment

    A framework for chemical safety assessment incorporating new approach methodologies within REACH

    No full text
    The long-term investment in new approach methodologies (NAMs) within the EU and other parts of the world is beginning to result in an emerging consensus of how to use information from in silico, in vitro and targeted in vivo sources to assess the safety of chemicals. However, this methodology is being adopted very slowly for regulatory purposes. Here, we have developed a framework incorporating in silico, in vitro and in vivo methods designed to meet the requirements of REACH in which both hazard and exposure can be assessed using a tiered approach. The outputs from each tier are classification categories, safe doses, and risk assessments, and progress through the tiers depends on the output from previous tiers. We have exemplified the use of the framework with three examples. The outputs were the same or more conservative than parallel assessments based on conventional studies. The framework allows a transparent and phased introduction of NAMs in chemical safety assessment and enables science-based safety decisions which provide the same level of public health protection using fewer animals, taking less time, and using less financial and expert resource. Furthermore, it would also allow new methods to be incorporated as they develop through continuous selective evolution rather than periodic revolution.publishe

    The European exposure science strategy 2020–2030

    No full text
    Exposure science is an emerging and rapidly growing field dedicated to all aspects concerning the contact between chemical, biological, physical or psycho-social stressors and human and ecological receptors. With that, exposure science plays a central role in protecting human and ecosystem health, and contributes to the global transition towards a green and sustainable society. In Europe, however, exposure science is currently not sufficiently recognised as a scientific field, resulting in inefficient uptake into policies. In response, the wider European exposure science community developed elements and actions under the auspices of the Europe Regional Chapter of the International Society of Exposure Science (ISES Europe), for identified priority areas, namely education, exposure models, exposure data, human biomonitoring, and policy uptake. In the present document, we synthesize these strategic elements into an overarching ‘European Exposure Science Strategy 2020–2030’, following three strategic objectives that focus on acknowledging exposure science as an independent and interconnected field, harmonizing approaches and tools across regulations, and exploring collaboration, education and funding mechanisms. To operationalise this strategy, we present concrete key actions and propose initiatives and funding options for advancing the underlying science, cultivating broader education and cross-sector exposure knowledge transfer, and fostering effective uptake of exposure information into policy. We aim at anchoring European efforts in the global exposure science context, with a special focus on the interface between scientific advancements, application in decision support, and dissemination and training. This will help to develop exposure science as a strong scientific field with the ultimate goal to successfully assess and manage various stressors across sectors and geographic scales.ISSN:0160-4120ISSN:1873-675

    Aggregate dermal exposure to cyclic siloxanes in personal care products:implications for risk assessment

    No full text
    Consumers who use personal care products (PCPs) are internally exposed to some of the organic components present of which some may be detected in exhaled air when eliminated. The aim of this study was the quantitative determination of octamethylcyclotetrasiloxane (D4) and decamethylcyclopentasiloxane (D5) in end-exhaled air to study dermal absorption of substances in PCPs. We exposed the forearm of fifteen healthy volunteers for 60 min to pure D4 or D5 and to commercial products containing D4 and D5. Inhalation uptake was kept to a minimum by keeping the forearm in a flow cabinet during dermal exposure and supplying filtered air to the breathing zone of the volunteer during the post-exposure period. End-exhaled air was collected using a breath sampler (Bio-VOC), transferred to carbograph multi-bed adsorbent tubes and analyzed by thermal desorption gas chromatography mass spectrometry (TD-GC-MS). In the end-exhaled air of non-exposed volunteers background concentrations of D4 (0.8–3.5 ng/L) and D5 (0.8–4.0 ng/L) were observed. After exposing the volunteers, the level of D4 and D5 in end-exhaled air did not or barely exceed background concentrations. At t = 90 min, a sharp increase of the D4/D5 concentration in end-exhaled air was observed, which we attributed to the inhalation of the substances during a toilet visit without using inhalation protection devices. When this visit was taken out of the protocol, the sharp increase disappeared. Overall, the results of our study indicate that dermal absorption of D4 and D5 contributes only marginally to internal exposure following dermal applications. As in our study inhalation is the primary route of entry for these compounds, we conclude that its risk assessment should focus on this particular exposure route
    corecore