452 research outputs found

    The lancet weight determines wheal diameter in response to skin prick testing with histamine

    Get PDF
    BACKGROUND:Skin prick test (SPT) is a common test for diagnosing immunoglobulin E-mediated allergies. In clinical routine, technicalities, human errors or patient-related biases, occasionally results in suboptimal diagnosis of sensitization. OBJECTIVE:Although not previously assessed qualitatively, lancet weight is hypothesized to be important when performing SPT to minimize the frequency of false positives, false negatives, and unwanted discomfort. METHODS:Accurate weight-controlled SPT was performed on the volar forearms and backs of 20 healthy subjects. Four predetermined lancet weights were applied (25 g, 85 g, 135 g and 265 g) using two positive control histamine solutions (1 mg/mL and 10 mg/mL) and one negative control (saline). A total of 400 SPTs were conducted. The outcome parameters were: wheal size, neurogenic inflammation (measured by superficial blood perfusion), frequency of bleeding, and the lancet provoked pain response. RESULTS:The mean wheal diameter increased significantly as higher weights were applied to the SPT lancet, e.g. from 3.2 ± 0.28 mm at 25 g to 5.4 ± 1.7 mm at 265 g (p<0.01). Similarly, the frequency of bleeding, the provoked pain, and the neurogenic inflammatory response increased significantly. At 265 g saline evoked two wheal responses (/160 pricks) below 3 mm. CONCLUSION AND CLINICAL RELEVANCE:The applied weight of the lancet during the SPT-procedure is an important factor. Higher lancet weights precipitate significantly larger wheal reactions with potential diagnostic implications. This warrants additional research of the optimal lancet weight in relation to SPT-guidelines to improve the specificity and sensitivity of the procedure

    Antigenic Proteins Involved in Occupational Rhinitis 1 and Asthma Caused by Obeche Wood (Triplochiton Scleroxylon)

    Get PDF
    Background Obeche wood dust is a known cause of occupational asthma where an IgE-mediated mechanism has been demonstrated. Objective To characterize the allergenic profile of obeche wood dust and evaluate the reactivity of the proteins by in vitro, ex vivo and in vivo assays in carpenters with confirmed rhinitis and/or asthma Materials and methods An in-house obeche extract was obtained, and two IgE binding bands were purified (24 and 12 kDa) and sequenced by N-terminal identity. Specific IgE and IgG, basophil activation tests and skin prick tests (SPTs) were performed with whole extract and purified proteins. CCD binding was analyzed by ELISA inhibition studies. Results Sixty-two subjects participated: 12 with confirmed occupational asthma/rhinitis (ORA+), 40 asymptomatic exposed (ORA−), and 10 controls. Of the confirmed subjects, 83% had a positive SPT to obeche. There was a 100% recognition by ELISA in symptomatic subjects vs. 30% and 10% in asymptomatic exposed subjects and controls respectively (p<0.05). Two new proteins were purified, a 24 kDa protein identified as a putative thaumatin-like protein and a 12 kDa gamma-expansin. Both showed allergenic activity in vitro, with the putative thaumatin being the most active, with 92% recognition by ELISA and 100% by basophil activation test in ORA+ subjects. Cross-reactivity due to CCD was ruled out in 82% of cases. Conclusions Two proteins of obeche wood were identified and were recognized by a high percentage of symptomatic subjects and by a small proportion of asymptomatic exposed subjects. Further studies are required to evaluate cross reactivity with other plant allergens

    Challenges for Allergy Diagnosis in Regions with Complex Pollen Exposures

    Get PDF
    Over the past few decades, significant scientific progress has influenced clinical allergy practice. The biological standardization of extracts was followed by the massive identification and characterization of new allergens and their progressive use as diagnostic tools including allergen micro arrays that facilitate the simultaneous testing of more than 100 allergen components. Specific diagnosis is the basis of allergy practice and is always aiming to select the best therapeutic or avoidance intervention. As a consequence, redundant or irrelevant information might be adding unnecessary cost and complexity to daily clinical practice. A rational use of the different diagnostic alternatives would allow a significant improvement in the diagnosis and treatment of allergic patients, especially for those residing in complex pollen exposure areas

    Exposure to allergens of different cattle breeds and their relevance in occupational allergy

    Get PDF
    Introduction Cattle are an important source of allergens in the working area of farmers. Asthma caused by cow allergens is a significant occupational problem. Yet in allergological testing, the results of in vivo and in vitro diagnostic tests are often inconsistent even in cases with clearly cattle-related symptoms. Objectives and methods The aim of this study was to investigate four different commercial cow allergen extracts and to compare them with self prepared extracts of different cattle breeds by means of SDS-PAGE and immunoblotting using the sera of 42 German farmers with asthma and rhino-conjunctivitis caused by cattle contact. Results The commercial extracts investigated in this study showed only minor differences in protein pattern. Using sera in immunoblotting experiments distinct bands were found for all symptomatic farmers, even in 13 farmers with a negative result in commercially available serological allergy tests. Bands with molecular weights in the range between about 11 and 67 kDa were observed; reactivity with the major allergen Bos d 2 at about 20 kDa was detected in all farmers, although it was not the strongest band in all cases. Conclusions We demonstrate for the first time the allergenic relevance of additional proteins with molecular weights of 14, 30, 55 and approx. 67-97 kDa in more than 50% of farmers with cattle related symptoms. One of our most striking results was that 32% of the investigated farmers with cattle related symptoms showed negative results with commercial serological tests but distinct reactions with cow allergen in immunoblotting experiments. The Bos d 2 content in hair showed differences between certain breeds whereas German Brown and Simmental had particularly higher quantities of Bos d 2 in their hair than breeds such as Holstein-Friesian. These results strongly support the following recommendation: test results with commercial extracts that are contradictory to the clinical symptoms should be supplemented by skin tests using extracts of the hair of the farmers' own cattle

    Are exhaled nitric oxide measurements using the portable NIOX MINO repeatable?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Exhaled nitric oxide is a non-invasive marker of airway inflammation and a portable analyser, the NIOX MINO (Aerocrine AB, Solna, Sweden), is now available. This study aimed to assess the reproducibility of the NIOX MINO measurements across age, sex and lung function for both absolute and categorical exhaled nitric oxide values in two distinct groups of children and teenagers.</p> <p>Methods</p> <p>Paired exhaled nitric oxide readings were obtained from 494 teenagers, aged 16-18 years, enrolled in an unselected birth cohort and 65 young people, aged 6-17 years, with asthma enrolled in an interventional asthma management study.</p> <p>Results</p> <p>The birth cohort participants showed a high degree of variability between first and second exhaled nitric oxide readings (mean intra-participant difference 1.37 ppb, 95% limits of agreement -7.61 to 10.34 ppb), although there was very close agreement when values were categorised as low, normal, intermediate or high (kappa = 0.907, p < 0.001). Similar findings were seen in subgroup analyses by sex, lung function and asthma status. Similar findings were seen in the interventional study participants.</p> <p>Conclusions</p> <p>The reproducibility of exhaled nitric oxide is poor for absolute values but acceptable when values are categorised as low, normal, intermediate or high in children and teenagers. One measurement is therefore sufficient when using categorical exhaled nitric oxide values to direct asthma management but a mean of at least two measurements is required for absolute values.</p

    Evolution through segmental duplications and losses : A Super-Reconciliation approach

    Get PDF
    The classical gene and species tree reconciliation, used to infer the history of gene gain and loss explaining the evolution of gene families, assumes an independent evolution for each family. While this assumption is reasonable for genes that are far apart in the genome, it is not appropriate for genes grouped into syntenic blocks, which are more plausibly the result of a concerted evolution. Here, we introduce the Super-Reconciliation problem which consists in inferring a history of segmental duplication and loss events (involving a set of neighboring genes) leading to a set of present-day syntenies from a single ancestral one. In other words, we extend the traditional Duplication-Loss reconciliation problem of a single gene tree, to a set of trees, accounting for segmental duplications and losses. Existency of a Super-Reconciliation depends on individual gene tree consistency. In addition, ignoring rearrangements implies that existency also depends on gene order consistency. We first show that the problem of reconstructing a most parsimonious Super-Reconciliation, if any, is NP-hard and give an exact exponential-time algorithm to solve it. Alternatively, we show that accounting for rearrangements in the evolutionary model, but still only minimizing segmental duplication and loss events, leads to an exact polynomial-time algorithm. We finally assess time efficiency of the former exponential time algorithm for the Duplication-Loss model on simulated datasets, and give a proof of concept on the opioid receptor genes

    Određivanje alergena Asp f 1 (Aspergillus fumigatus) u peradarniku enzimimunokemijskom metodom

    Get PDF
    Poultry farms contain high levels of allergenic fungi, and Aspergillus spp. is the most common genus of moulds. Aspergillus fumigatus antigens are responsible for the development of several respiratory diseases including asthma. The aim of this study was to measure the mass fraction of Asp f 1, a major allergen of Asperillus fumigatus in 37 indoor dust samples collected from four poultry farms in a rural area of the Zagreb County (Croatia) using the enzyme-linked immunosorbent assay. More than 62 % of dust samples had detectable Asp f 1 levels (limit of detection 3.6 ng g-1). The overall mean Asp f 1 level was 17.9 ng g-1 [range (3.8 to 72.4) ng g-1]. Satisfactory results were obtained for analytical within-run imprecision (6.7 %), between-run imprecision (10.5 %), and accuracy (91 % to 115 %). Microclimate parameters (air temperature, relative humidity, and velocity) were within the recommended ranges in all poultry farms. This study has shown that Asp f 1 settles on dust at poultry farms and that occupational exposure to this allergen deserves monitoring in livestock buildings.Peradarnici sadržavaju veliku koncentraciju alergenih plijesni, a rod Aspergillus najčešće je zastupljen. Antigeni soja Aspergillus fumigatus odgovorni su za nastanak nekoliko respiratornih bolesti uključujući astmu. Cilj ovoga rada bio je odrediti masenu frakciju Asp f 1, glavnog alergena soja Asperillus fumigatus u 37 uzoraka prašine uzorkovanih u četiri peradarnika sa šireg područja Zagrebačke županije rabeći enzimimunokemijsku metodu. Više od 62 % uzoraka prašine u tri peradarnika imalo je mjerljivu koncentraciju Asp f 1 (granica detekcije = 3.6 ng g-1). Ukupni srednji maseni udio Asp f 1 iznosio je 17.9 ng g-1 (raspon od 3.8 ng g-1 do 72.4 ng g-1). Dobiveni su zadovoljavajući rezultati za analitičku nepreciznost u seriji (6.7 %), nepreciznost iz dana u dan (10.5 %) i točnost (91 % do 115 %). Mikroklimatski parametri (temperatura zraka, relativna vlaga i protok zraka) u svim peradarnicima bili su u okviru preporučenih vrijednosti. Rezultati ovoga rada pokazuju da Asp f 1 sedimentira na prašinu u peradarnicima te da profesionalnu izloženost tom alergenu treba pratiti u jedinicama za uzgoj stoke

    Laboratorial approach in the diagnosis of food allergy

    Get PDF
    OBJCTIVE: Review the available laboratory tests used to assist in the diagnosis of IgE-mediated and non-IgE-mediated food allergy. DATA SOURCES: Papers in English and Portuguese published in PubMed and Embase, in the last ten years. Terms searched were food allergy, diagnose and laboratory, isolated and/or associated. DATA SYNTHESIS: The diagnostic approach to food allergy reactions includes a good medical history, laboratory studies, elimination diets and blinded food challenges. More recently, the use of a quantitative measurement of food-specific IgE antibodies has been shown to be more predictive of symptomatic IgE-mediated food allergy. Food-specific IgE serum levels exceeding the diagnostic values indicate that the patient is greater than 95% likely to experience an allergic reaction if he/she ingests the specific food. Such decision point values have been defined just for some foods and inconsistent results were obtained when allergy to the same food was studied in different centers. Food challenges, in particular the double-blind placebo-controlled food challenge (DBPCFC), represent the most reliable way to establish or rule out food hypersensitivity. CONCLUSIONS: A number of recent developments are improving the predictive value of some laboratory tests for the diagnosis of food allergies. However, to date, no in-vitro or in-vivo test shows full correlation with clinical food allergy and the DBPCFC remains the gold standard for the definitive diagnosis of specific food allergies. There is an urgent need for new and fundamentally improved diagnostic approaches, which must be validated in patients with food allergy confirmed by a positive DBPCFC.OBJETIVO: Revisar os exames laboratoriais disponíveis utilizados no diagnóstico da alergia alimentar mediada ou não por IgE. FONTES DE DADOS: Artigos publicados em base de dados PubMed e Embase (língua inglesa e portuguesa) nos últimos dez anos. As palavras-chave utilizadas como fonte de busca foram alergia alimentar, diagnóstico e laboratório, isolados e/ou associados. SÍNTESE DOS DADOS: A abordagem diagnóstica das reações alérgicas a alimentos inclui história clínica completa, estudos laboratoriais, dietas de eliminação e desencadeamentos cegos com alimentos. Recentemente, a medida quantitativa de anticorpos IgE específicos a alimentos tem mostrado ser mais preditiva de alergia alimentar sintomática mediada por IgE. Níveis séricos de IgE específica a alimento que excedam os valores diagnósticos indicam que o paciente tem chance maior que 95% de apresentar uma reação alérgica se ingerir o alimento em questão. Estes valores de decisão foram definidos para alguns alimentos e resultados inconsistentes são obtidos ao se estudar diferentes populações. Os desencadeamentos com alimento, especialmente o duplo-cego controlado por placebo (DADCCP), representa a maneira mais confiável de estabelecer ou descartar o diagnóstico de hipersensibilidade alimentar. CONCLUSÕES: Número crescente de aquisições tem melhorado o valor preditivo de alguns testes laboratoriais empregados no diagnóstico de alergias alimentares. Entretanto, até hoje, não há teste in vitro ou in vivo que mostre correlação completa com a clínica da alergia alimentar. O DADCCP continua sendo o padrão-ouro no diagnóstico definitivo de alergia alimentar específica. São necessárias, urgentemente, novas abordagens diagnósticas válidadas em pacientes com alergia alimentar confirmada por DADCCP positivo.Universidade Federal de São Paulo (UNIFESP) Escola Paulista de Medicina Departamento de PediatriaUNIFESP-EPM Departamento de PediatriaUniversidade de São Paulo Faculdade de Medicina Departamento de PediatriaUniversidade Federal da Bahia Departamento de PediatriaUNIFESP-EPMUniversidade Federal do Paraná Departamento de PediatriaUNIFESP, EPM, Depto. de PediatriaUNIFESP, EPM Depto. de PediatriaUNIFESP, EPMSciEL
    corecore