646 research outputs found

    New trends in femtosecond Pulsed Laser Deposition and femtosecond produced plasma diagnostics

    No full text
    International audienceThe availability of compact table top amplified femtosecond lasers and the technical simplicity of experimental design have opened the way to many recent and fast developments towards thin film elaboration by Pulsed Laser Deposition (PLD) with ultra short laser pulses, with the aim of producing materials of high quality previously unattainable or attainable only through more complex means. The first developments of PLD using femtosecond lasers were made on Diamond-Like Carbon thin films elaboration, with the attempt to reach high sp3 content. PLD with ultra short pulses was used recently to deposit several systems such as quasicrystals or oxides with a transfer of the target composition to the deposited films, even for compounds with complex stoechiometry. Femtosecond laser ablation from solid targets has shown its capability in producing nanoparticles of different materials, even in high vacuum conditions. Nanostructured films of doped Diamond-Like Carbon were obtained recently, opening the way to large applications towards functional materials. The characteristics of the plasma are a well-suited signature of the physics of laser-matter interaction and plasma plume creation and expansion. Recent studies on the control of the film growth and femtosecond PLD processes will be reported. Emphasis on actual capability of the existing sources to elaborate high quality materials will be questioned in terms of energy per pulse, time width, repetition rates but also in the need for further source development and beam shaping improvement

    Theory of magnetic domains in uniaxial thin films

    Full text link
    For uniaxial easy axis films, properties of magnetic domains are usually described within the Kittel model, which assumes that domain walls are much thinner than the domains. In this work we present a simple model that includes a proper description of the magnetostatic energy of domains and domain walls and also takes into account the interaction between both surfaces of the film. Our model describes the behavior of domain and wall widths as a function of film thickness, and is especially well suited for the strong stripe phase. We prove the existence of a critical value of magneto-crystalline anisotropy above which stripe domains exist for any film thickness and justify our model by comparison with exact results. The model is in good agreement with experimental data for hcp cobalt.Comment: 15 pages, 7 figure

    Is positive communication sufficient to modulate procedural pain and anxiety in the emergency room? A randomized controlled trial.

    Get PDF
    Research suggests that therapeutic communication could enhance patient comfort during medical procedures. Few studies have been conducted in clinical settings, with adequate blinding. Our hypothesis was that a positive message could lead to analgesia and anxiolysis, and that this effect would be enhanced by an empathetic interaction with the nurse performing the procedure, compared to an audio-taped message. This study aimed to modulate the contents and delivery vector of a message regarding peripheral intravenous catheter (PIC) placement in the emergency room (ER). This study was a 2 + 2 randomized controlled trial registered on clinicaltrials.gov (NCT03502655). A positive versus standard message was delivered through audio tape (double blind) in the first phase (N = 131) and through the nurse placing the catheter (single blind) in the second phase (N = 120). By design, low practitioner empathic behavior was observed in the first phase (median 1 out of 5 points). In the second phase, higher empathic behavior was observed in the positive than in the standard message (median 2 vs. 3, p < 0.001). Contrary to our hypothesis, the intervention did not affect pain nor anxiety reports due to PIC placement in either phase (all p values>0.2). The positive communication intervention did not impact pain nor anxiety reports following PIC. There might have been a floor effect, with low PIC pain ratings in a context of moderate pain due to the presenting condition. Hence, such a therapeutic communication intervention might not be sufficient to modulate a mild procedural pain in the ER

    Effect of sputter gas on the physical and magnetic microstructure of Co/Cu multilayers

    Get PDF
    The physical structure of Co/Cu multilayers, sputtered in different gases (Ar, Kr, and Xe) together with the domain structures that these films support have been investigated using electron microscopy in an attempt to explain the differences in their measured magnetoresistance (MR). Both planar and cross‐sectional analyses were undertaken. Due to only partial antiferromagnetic coupling submicron domain structures were observed by Lorentz microscopy in all multilayers. The complex nature of these domain structures made classification difficult, although small magnetic field application allowed wall motion and nucleation to be observed. All films were polycrystalline in nature, although average grains sizes differed. However, smoother interfaces together with less well defined crystal boundaries were observed in the Kr and Xe sputtered films. This trend did not correlate with giant MR (GMR) measurements as the Xe sputtered films had the lowest GMR value of the three

    Characterization of different DLC and DLN electrodes for biosensor design

    No full text
    International audienceDiamond-Like Carbon and Carbon-Like Nanocomposite electrodes, novel materials in the field of biosensors, made with different ratio of sp3/sp2 carbon hybridization or doped with elements such as Ni, Si and W, were characterized electrochemically by cyclic voltammetry and by amperometric measurements towards hydrogen peroxide. SiCAr1 and SiCNi5% were chosen as sensitive transducers for elaboration of amperometric glucose biosensors. Immobilization of glucose oxidase was carried out by cross-linking with glutareldehyde. Measurements were made at a fixed potential + 1.0 V in 40 mM phosphate buffer pH 7.4. SiCAr1 seems to be more sensitive for glucose (0.6875 µA/mM) then SiCNi5% (0.3654 µA/mM). Detections limits were respectively 20 µM and 30 µM. Michaelis-Menten constants for the two electrodes were found around 3 mM. 48% and 79% of the original response for 0.5 mM glucose remained respectively for both electrodes after 10 days

    Unconventional magnetism in all-carbon nanofoam

    Get PDF
    We report production of nanostructured carbon foam by a high-repetition-rate, high-power laser ablation of glassy carbon in Ar atmosphere. A combination of characterization techniques revealed that the system contains both sp2 and sp3 bonded carbon atoms. The material is a novel form of carbon in which graphite-like sheets fill space at very low density due to strong hyperbolic curvature, as proposed for ?schwarzite?. The foam exhibits ferromagnetic-like behaviour up to 90 K, with a narrow hysteresis curve and a high saturation magnetization. Such magnetic properties are very unusual for a carbon allotrope. Detailed analysis excludes impurities as the origin of the magnetic signal. We postulate that localized unpaired spins occur because of topological and bonding defects associated with the sheet curvature, and that these spins are stabilized due to the steric protection offered by the convoluted sheets.Comment: 14 pages, including 2 tables and 7 figs. Submitted to Phys Rev B 10 September 200

    Structure, electrochemical properties and functionalization of amorphous CN films deposited by femtosecond pulsed laser ablation

    Get PDF
    Amorphous carbon nitride (a-C:N) material has attracted much attention in research and development. Recently, it has become a more promising electrode material than conventional carbon based electrodes in electrochemical and biosensor applications. Nitrogen containing amorphous carbon (a-C:N) thin films have been synthesized by femtosecond pulsed laser deposition (fs-PLD) coupled with plasma assistance through Direct Current (DC) bias power supply. During the deposition process, various nitrogen pressures (0 to 10 Pa) and DC bias (0 to ¿ 350 V) were used in order to explore a wide range of nitrogen content into the films. The structure and chemical composition of the films have been studied by using Raman spectroscopy, electron energy-loss spectroscopy (EELS) and high-resolution transmission electron microscopy (HRTEM). Increasing the nitrogen pressure or adding a DC bias induced an increase of the N content, up to 21 at.%. Nitrogen content increase induces a higher sp2 character of the film. However DC bias has been found to increase the film structural disorder, which was detrimental to the electrochemical properties. Indeed the electrochemical measurements, investigated by cyclic voltammetry (CV), demonstrated that a-C:N film with moderate nitrogen content (10 at.%) exhibited the best behavior, in terms of reversibility and electron transfer kinetics. Electrochemical grafting from diazonium salts was successfully achieved on this film, with a surface coverage of covalently bonded molecules close to the dense packed monolayer of ferrocene molecules. Such a film may be a promising electrode material in electrochemical detection of electroactive pollutants on bare film, and of biopathogen molecules after surface grafting of the specific affinity receptor.This work is produced with the financial support of the Future Program Lyon Saint-Etienne (PALSE) from the University of Lyon (ANR-11-IDEX-0007), under the “Investissements d'Avenir” program managed by the National Agency Research (ANR)

    A Carbon Nanofilament-Bead Necklace

    Get PDF
    Carbon nanofilaments with carbon beads grown on their surfaces were successfully synthesized reproducibly by a floating catalyst CVD method. The nanofilaments hosting the pearl-like structures typically show an average diameter of about 60 nm, which mostly consists of low-ordered graphite layers. The beads with diameter range 150−450 nm are composed of hundreds of crumpled and random graphite layers. The mechanism for the formation of these beaded nanofilaments is ascribed to two nucleation processes of the pyrolytic carbon deposition, arising from a temperature gradient between different parts of the reaction chamber. Furthermore, the Raman scattering properties of the beaded nanofilaments have been measured, as well as their confocal Raman G-line images. The Raman spectra reveal that that the trunks of the nanofilaments have better graphitic properties than the beads, which is consistent with the HRTEM analysis. The beaded nanofilaments are expected to have high potential applications in composites, which should exhibit both particle- and fiber-reinforcing functions for the host matrixes

    Electrochemical Boron-Doped Diamond Film Microcells Micromachined with Femtosecond Laser: Application to the Determination of Water Framework Directive Metals

    No full text
    Planar electrochemical microcells were micromachined in a microcrystalline boron-doped diamond (BDD) thin layer using a femtosecond laser (Photo 1). The electrochemical performances of the new laser-machined BDD microcell were assessed by differential pulse anodic stripping voltammetry (DPASV) determinations, at nM level, of the four heavy metal ions of the European Water Framework Directive (WFD): Cd(II), Ni(II), Pb(II), Hg(II). The results are compared with those of previously published BDD electrodes [1]. The calculated detection limits are 0.4 nM, 6.8 nM and 5.5 nm 2.3 nM, and the linearities go up to 35nM, 97nM, 48nM and 5nM for respectively Cd(II), Ni(II) Pb(II) and Hg(II). The detection limits meet with the environmental quality standard of the WFD for three of the four metals. It was shown that the four heavy metals could be detected simultaneously, in the concentration ratio usually measured in sewage or runoff waters
    corecore