55 research outputs found

    Control of mandibular incisors with the combined Herbst and completely customized lingual appliance - a pilot study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The traditional Herbst appliance induces mandibular incisor proclination independent of the anchorage system used. The dental effects of the Herbst appliance as an element of a completely customized lingual orthodontic (LO) appliance (Incognito, 3 M) has not been analyzed yet and the aim of this paper was to measure the effect of mandibular incisor proclination using this Herbst-LO device.</p> <p>Methods</p> <p>Retrospective study. Inclusion criteria: a) Class II ≥ 5 mm molar relationship; b) Herbst appliance ≥ 9 months in situ; and c) finished active treatment. Incisor position was measured on digital models before treatment, on the digital target setup, and on digital models obtained at the day of debonding. All measurements were performed by one investigator.</p> <p>Results</p> <p>Twelve patients (8 females, 4 males) out of 632 cases treated with a lingual appliance were included in the study. The measurement error computed with Dahlberg's formula was 0.2°. Seven cases had planned (target setup) mandibular incisor uprighting (ccr), and five cases had proclination (clockwise rotation). There was no statistical difference (p > 0.05) between planned incisor rotations of the target setup and achieved incisor rotations at the day of debonding. The overall mean difference was 2.2° ± 1.0°.</p> <p>Conclusions</p> <p>The Incognito-Herbst combination is the first Herbst device with full control over mandibular incisor movement. Using this system, anchorage loss or anchorage gain is independent of the Herbst treatment. It depends only on the planned tooth position of the individual target setup.</p

    Analysis of the torque capacity of a completely customized lingual appliance of the next generation

    Get PDF
    INTRODUCTION: In lingual orthodontic therapy, effective torque control of the incisors is crucial due to the biomechanical particularities associated with the point of force application and the tight link between third order deviations and vertical tooth position. AIM: The aim of the present in vitro investigation was to analyze the torque capacity of a completely customized lingual appliance of the next generation (WIN) in combination with different finishing archwire dimensions. METHODS: Using a typodont of the upper arch carrying the WIN appliance, slot filling and undersized individualized β-titanium archwires were engaged. Horizontal forces ranging from 0 to 100 cN were applied at the central incisor by means of spring gauges. The resulting angular deviations were recorded and the corresponding torque moments were calculated. RESULTS: For fullsize archwires (0.018”×0.018” β-titanium and 0.018”×0.025” β-titanium), an initial torque play of 0-2° had to be overcome prior to the development of an effective torque moment. Thereafter, a linear correlation between torque angle and torque moment developed for both archwire dimensions with steeper slopes calculated for the specimens with the larger dimension. A torque moment of 2 Nmm required for effective torque correction was noted after a minimum of 2-3° of twist for the 0.018”×0.018” β-titanium wires as compared to 2-4° for the 0.018”×0.025” β-titanium study sample. When undersized archwires were analyzed (0.0175”×0.0175” β-titanium), the measured torque play ranged from 5-7°. After 8-12° of torque angle, the threshold of 2 Nmm was reached. A linear relationship between twist angle and torque moment in which the steepness of the slopes was generally flatter than the ones calculated for the slot filling archwires was noted. CONCLUSIONS: Given the high precision of the bracket slot-archwire-combination provided with the WIN appliance, an effective torque control can be clinically realized

    The University Münster model surgery system for Orthognathic surgery. Part I – The idea behind

    Full text link
    Background: We describe a procedure for diagnosis and planning for orthognatic surgery based on international standards. A special 2D planning based on lateral cephalograms (Axis Orbital Marker Lines System) realize a transmission to the SAM 2P articulator (3D) by means of the Axis Orbital Plane. Methods: Former intraoperative measurement of the average height of the LeFort I osteotomy plane relative to the molar occlusal plane allow to construct a virtual osteotomy plane in the lateral cephalogram. This is the basis for the development of the Axis Orbital Marker Lines System (AO-MLS). Results: The AO-MLS is presented graphically, and in detail, with construction guidelines. The system could be integrated into various lateral cephalometric analysis- and surgical prediction schemes. It forms the basis for a standardized transfer of the 2D planning to the 3D planning in the articulator, and vice versa. This procedure makes it possible to generate surgical planning protocols based on the model surgery, which represent the dislocations in the proximity of the real osteotomy planes. Conclusions: The Axis Orbital Marker Lines System (software component) in conjunction with the University Münster Model Surgery System (hardware system) increases the predictability of model operations in orthognathic surgery

    The effect of e-learning on the quality of orthodontic appliances

    Full text link
    Purpose: The effect of e-learning on practical skills in medicine has not yet been thoroughly investigated. Today’s multimedia learning environment and access to e-books provide students with more knowledge than ever before. The aim of this study is to evaluate the effect of online demonstrations concerning the quality of orthodontic appliances manufactured by undergraduate dental students. Materials and methods: The study design was a parallel-group randomized clinical trial. Fifty-four participants were randomly assigned to one of the three groups: 1) conventional lectures, 2) conventional lectures plus written online material, and 3) access to resources of groups one and two plus access to online video material. Three orthodontic appliances (Schwarz Plate, U-Bow Activator, and Fränkel Regulator) were manufactured during the course and scored by two independent raters blinded to the participants. A 15-point scale index was used to evaluate the outcome quality of the appliances. Results: In general, no significant differences were found between the groups. Concerning the appliances, the Schwarz Plate obtained the highest scores, whereas the Fränkel Regulator had the lowest scores; however, these results were independent of the groups. Females showed better outcome scores than males in groups two and three, but the difference was insignificant. Age of the participants also had no significant effect. Conclusion: The offer that students could use additional time and course-independent e-learning resources did not increase the outcome quality of the orthodontic appliances. The advantages of e-learning observed in the theoretical fields of medicine were not achieved in the educational procedures for manual skills. Factors other than e-learning may have a higher impact on manual skills, and this should be investigated in further studies

    10-year anniversary of the European Somnologist examination - A historic overview and critical appraisal

    Get PDF
    The European Somnologist certification programme was developed by the European Sleep Research Society to improve patient care in sleep medicine by providing an independent evaluation of theoretical and practical knowledge. The examination of eligible experts plays a key role in this procedure. A process was started more than 15 years ago to create the European sleep medicine curriculum, eligibility criteria for certification, and sleep centre accreditation criteria. The process was characterised by interdisciplinary collaboration, consensus, and achieving new solutions. During the past 10 years, experience has been gained by the examination and certification of more than 1000 sleep medicine experts from more than 50 countries. The process has continuously been improved. However, as the programme was designed and administered mainly by medical experts in the field, systematic influence from teaching and pedagogic experts was partially underrepresented. The current critical appraisal pinpoints several missing links in the process - mainly as a missing constructive alignment between learning objectives, learning and teaching activities, and the final assessment. A series of suggestions has been made to further improve the ESRS certification programme.Peer reviewe
    corecore