28 research outputs found

    Electrochemical oxidation of water on synthetic boron-doped diamond thin film anodes

    Get PDF
    Electrolysis in aqueous 1 M HClO4 and 1 M H2SO4 solutions has been carried out under galvanostatic conditions using boron-doped diamond electrodes (BDD). Analyses of the oxidation products have shown that in 1 M HClO4 the main reaction is oxygen evolution, while in H2SO4 the main reaction is the formation of H2S2O8. In both electrolytes small amounts of O3 and H2O2 are formed. Finally, a simplified mechanism involving hydroxyl radicals formed by water discharge has been proposed for water oxidation on boron-doped diamond anode

    Measurement of Epstein-Barr virus DNA load using a novel quantification standard containing two EBV DNA targets and SYBR Green I dye

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Reactivation of Epstein-Barr virus (EBV) infection may cause serious, life-threatening complications in immunocompromised individuals. EBV DNA is often detected in EBV-associated disease states, with viral load believed to be a reflection of virus activity. Two separate real-time quantitative polymerase chain reaction (QPCR) assays using SYBR Green I dye and a single quantification standard containing two EBV genes, Epstein-Barr nuclear antigen-1 (EBNA-1) and BamHI fragment H rightward open reading frame-1 (BHRF-1), were developed to detect and measure absolute EBV DNA load in patients with various EBV-associated diseases. EBV DNA loads and viral capsid antigen (VCA) IgG antibody titres were also quantified on a population sample.</p> <p>Results</p> <p>EBV DNA was measurable in ethylenediaminetetraacetic acid (EDTA) whole blood, peripheral blood mononuclear cells (PBMCs), plasma and cerebrospinal fluid (CSF) samples. EBV DNA loads were detectable from 8.0 Ă— 10<sup>2 </sup>to 1.3 Ă— 10<sup>8 </sup>copies/ml in post-transplant lymphoproliferative disease (n = 5), 1.5 Ă— 10<sup>3 </sup>to 2.0 Ă— 10<sup>5 </sup>copies/ml in infectious mononucleosis (n = 7), 7.5 Ă— 10<sup>4 </sup>to 1.1 Ă— 10<sup>5 </sup>copies/ml in EBV-associated haemophagocytic syndrome (n = 1), 2.0 Ă— 10<sup>2 </sup>to 5.6 Ă— 10<sup>3 </sup>copies/ml in HIV-infected patients (n = 12), and 2.0 Ă— 10<sup>2 </sup>to 9.1 Ă— 10<sup>4 </sup>copies/ml in the population sample (n = 218). EBNA-1 and BHRF-1 DNA were detected in 11.0% and 21.6% of the population sample respectively. There was a modest correlation between VCA IgG antibody titre and BHRF-1 DNA load (rho = 0.13, p = 0.05) but not EBNA-1 DNA load (rho = 0.11, p = 0.11).</p> <p>Conclusion</p> <p>Two sensitive and specific real-time PCR assays using SYBR Green I dye and a single quantification standard containing two EBV DNA targets, were developed for the detection and measurement of EBV DNA load in a variety of clinical samples. These assays have application in the investigation of EBV-related illnesses in immunocompromised individuals.</p

    Electrochemical oxidation of water on synthetic boron-doped diamond thin film anodes

    No full text
    Electrolysis in aqueous 1 M HClO4 and 1 M H2SO4 solutions has been carried out under galvanostatic conditions using boron-doped diamond electrodes (BDD). Analyses of the oxidation products have shown that in 1 M HClO4 the main reaction is oxygen evolution, while in H2SO4 the main reaction is the formation of H2S2O8. In both electrolytes small amounts of O3 and H2O2 are formed. Finally, a simplified mechanism involving hydroxyl radicals formed by water discharge has been proposed for water oxidation on boron-doped diamond anode

    Dimensionally Stable Anode-Type Anode Based on Conductive p-Silicon Substrate

    No full text
    In the search for a good dimensionally stable anode-type electrode, p-silicon (1-3 mW cm) has been chosen as the substrate material due to its high anodic stability and its reasonable cost compared to titanium and tantalum. Several p-Si/IrO2 electrodes have been prepd. by thermal decompn. at different temp. The effect of prepn. temp. on the morphol. and electrochem. properties has been investigated by SEM anal., X-ray diffraction, and cyclic voltammetry in 1 M HClO4 showing that p-Si/IrO2 prepd. at 450 DegC presents a high surface area and a low degree of crystallinity, while increasing the calcination temp. resulted in a decrease of true area and an increase in crystallite size. The activity of p-Si/IrO2 electrodes for simple electron transfer reactions and for complex electrode reactions has been also studied by cyclic voltammetry and linear polarization in solns. contg. the hydroquinone/benzoquinone redox couple and various org. compds. (isopropanol, tert-butanol, methanol). Finally, the anodic stability of a p-Si/IrO2 electrodes prepd. at 450 DegC has been tested by an accelerated service life test. p-Silicon based electrodes were shown to have the highest standardized service life compared with that of titanium- or tantalum-based electrodes. [on SciFinder (R)

    Preventive cardiology: comparisons of European and Italian projects with the Cardiac Units from Emilia Romagna region. A workshop of IACPR/GICR - Emilia Romagna

    No full text
    A workshop endorsed by the Italian Association of Cardiovascular Prevention and Rehabilitation--Emilia Romagna Section--held in Piacenza in May 2011, gave the opportunity to discuss the emerging role of Preventive Cardiology in the modern era. From the new documents recently published by the European and Italian Scientific Associations, the barriers in their implementation, and the contribution of the health care providers, physicians, nurses, both in primary and secondary prevention were discussed. The local initiatives of cardiac prevention in different areas were presented and compared. A new project of secondary prevention in the follow-up and management of patients with dilated cardiomyopathy and heart failure promoted by the Emilia Romagna Region Health Authority was presented

    Lower extremities peripheral arterial disease among patients admitted to cardiac rehabilitation: the THINKPAD registry

    No full text
    BACKGROUND/OBJECTIVES: Lower extremities peripheral arterial disease (LE-PAD) across the wide range of conditions for Cardiac Rehabilitation (CR) is poorly understood. The "ATHerosclerosis of the lower extremIties as a liNKed comorbidity in Patients Admitted for carDiac rehabilitation" (THINKPAD) registry explored LE-PAD in CR patients in terms of prevalence and interventions delivered. METHODS: Multicenter, consecutive case series of 1506 patients discharged from 16 CR Units in Italy from May 1 to June 30, 2012. RESULTS: LE-PAD constituted a primary indication for CR and a comorbidity on admission in 2.6% and 9.3% of patients respectively. LE-PAD patients were significantly older (72 ± 9 vs. 67 ± 12 years, p<0.001) and displayed a worse cardiovascular risk profile (diabetes 38% vs. 23%, hypertension 86% vs. 63%, hypercholesterolemia 74% vs. 52%, smoking 72% vs. 50%, low level of physical activity 84% vs. 69%, impaired diet habits 69% vs. 55%, p<0.01 for all). COPD (17% vs. 11%, p<0.05), CKD (20% vs. 10%, p<0.01), and past history of coronary revascularization (29% vs. 14%, p<0.001) were also more represented in the LE-PAD group. Half of LE-PAD patients received a formal staging, with low provision of ABI (18%) and color Doppler (48%) investigation. Secondary prevention targets at the end of CR for blood pressure and lipid control were accomplished in 83% and 46% of patients respectively (strongly correlated with the presence of CAD), while other guideline-recommended drugs for LE-PAD were prescribed in less than 4% of cases. CONCLUSION: LE-PAD represents an uncommon referral indication for CR. Our data confirm its systematic underassessment and undertreatmen
    corecore