    Tactile sensing and control of robotic manipulator integrating fiber Bragg grating strain-sensor

    Get PDF
    Tactile sensing is an instrumental modality of robotic manipulation, as it provides information that is not accessible via remote sensors such as cameras or lidars. Touch is particularly crucial in unstructured environments, where the robot’s internal representation of manipulated objects is uncertain. In this study we present the sensorization of an existing artificial hand, with the aim to achieve fine control of robotic limbs and perception of object’s physical properties. Tactile feedback is conveyed by means of a soft sensor integrated at the fingertip of a robotic hand. The sensor consists of an optical fiber, housing Fiber Bragg Gratings (FBGs) transducers, embedded into a soft polymeric material integrated on a rigid hand. Through several tasks involving grasps of different objects in various conditions, the ability of the system to acquire information is assessed. Results show that a classifier based on the sensor outputs of the robotic hand is capable of accurately detecting both size and rigidity of the operated objects (99.36 and 100% accuracy, respectively). Furthermore, the outputs provide evidence of the ability to grab fragile objects without breakage or slippage e and to perform dynamic manipulative tasks, that involve the adaptation of fingers position based on the grasped objects’ condition

    Tactile Sensing and Control of Robotic Manipulator Integrating Fiber Bragg Grating Strain-Sensor

    Get PDF
    Tactile sensing is an instrumental modality of robotic manipulation, as it provides information that is not accessible via remote sensors such as cameras or lidars. Touch is particularly crucial in unstructured environments, where the robot's internal representation of manipulated objects is uncertain. In this study we present the sensorization of an existing artificial hand, with the aim to achieve fine control of robotic limbs and perception of object's physical properties. Tactile feedback is conveyed by means of a soft sensor integrated at the fingertip of a robotic hand. The sensor consists of an optical fiber, housing Fiber Bragg Gratings (FBGs) transducers, embedded into a soft polymeric material integrated on a rigid hand. Through several tasks involving grasps of different objects in various conditions, the ability of the system to acquire information is assessed. Results show that a classifier based on the sensor outputs of the robotic hand is capable of accurately detecting both size and rigidity of the operated objects (99.36 and 100% accuracy, respectively). Furthermore, the outputs provide evidence of the ability to grab fragile objects without breakage or slippage e and to perform dynamic manipulative tasks, that involve the adaptation of fingers position based on the grasped objects' condition

    Reversal of Hartmann's procedure through the stomal side: A new even more minimal invasive technique

    Get PDF
    Background: Several minimal invasive, mainly laparoscopic-assisted, techniques for reversal of Hartmann's procedure (HP) have been published. The purpose of this pilot study was to assess a minimal invasive procedure through the stomal site that may compare favorably with open or laparoscopic-assisted procedures in terms of operative time, hospital stay and postoperative complications. Methods: HP reversal through the stomal side was attempted in 13 consecutive patients. Lysis of intra-abdominal adhesions was done manually through an incision at the formal stoma side, without direct vision between thumb and index finger. The rectal stump was identified intra-abdominally using a transanal rigid club. A manually controlled stapled end-to-end colorectal anastomosis was created. Results: Mean duration of operation was 81 min (range 58-109 min); mean hospital stay was 4.2 days (range 2-7 days). In two patients the procedure was converted because of strong adhesions in the lower pelvic cavity around the rectal stump that could not be lysed manually safely. No complications occurred in the patients in whom reversal was completely done through the stomal site. Conclusions: In our opinion, restoration of intestinal continuity through the stomal side after HP is a feasible operation, without need for additional incisions. In the hands of a specialist gastrointestinal surgeon this technique can be attempted in all patients, as conversion to a laparoscopic-assisted or an open procedure can be performed when necessary

    The complex TIE between macrophages and angiogenesis

    Get PDF
    Macrophages are primarily known as phagocytic immune cells, but they also play a role in diverse processes, such as morphogenesis, homeostasis and regeneration. In this review, we discuss the influence of macrophages on angiogenesis, the process of new blood vessel formation from the pre-existing vasculature. Macrophages play crucial roles at each step of the angiogenic cascade, starting from new blood vessel sprouting to the remodelling of the vascular plexus and vessel maturation. Macrophages form promising targets for both pro- and anti-angiogenic treatments. However, to target macrophages, we will first need to understand the mechanisms that control the functional plasticity of macrophages during each of the steps of the angiogenic cascade. Here, we review recent insights in this topic. Special attention will be given to the TIE2-expressing macrophage (TEM), which is a subtype of highly angiogenic macrophages that is able to influence angiogenesis via the angiopoietin-TIE pathway

    Tactile Sensing and Control of Robotic Manipulator Integrating Fiber Bragg Grating Strain-Sensor

    Get PDF
    Tactile sensing is an instrumental modality of robotic manipulation, as it provides information that is not accessible via remote sensors such as cameras or lidars. Touch is particularly crucial in unstructured environments, where the robot's internal representation of manipulated objects is uncertain. In this study we present the sensorization of an existing artificial hand, with the aim to achieve fine control of robotic limbs and perception of object's physical properties. Tactile feedback is conveyed by means of a soft sensor integrated at the fingertip of a robotic hand. The sensor consists of an optical fiber, housing Fiber Bragg Gratings (FBGs) transducers, embedded into a soft polymeric material integrated on a rigid hand. Through several tasks involving grasps of different objects in various conditions, the ability of the system to acquire information is assessed. Results show that a classifier based on the sensor outputs of the robotic hand is capable of accurately detecting both size and rigidity of the operated objects (99.36 and 100% accuracy, respectively). Furthermore, the outputs provide evidence of the ability to grab fragile objects without breakage or slippage e and to perform dynamic manipulative tasks, that involve the adaptation of fingers position based on the grasped objects' condition

    The Use of a Compression Device as an Alternative to Hand-Sewn and Stapled Colorectal Anastomoses: Is Three a Crowd?

    Get PDF
    BackgroundThe NiTi CAR™ 27 is a newer device that uses compression to create an anastomosis. An analysis of this device in the creation of colorectal anastomoses in humans has yet to be reported in the USA.MethodsA non-randomized, prospective pilot study of the NiTi CAR™ 27 device in patients undergoing a left-sided colectomy between March 2008 and August 2009 was performed.ResultsTwenty-three patients (9 men and 14 women) underwent a left-sided colectomy and compression anastomosis with the CAR™ 27 device. Minor morbidities, 3 of 23 (13%) patients, included one small postoperative abscess requiring antibiotics alone and two postoperative anastomotic strictures requiring balloon dilation. Major morbidities, 1 of 23 (4%) patients, included a partial anastomotic dehiscence/leak requiring surgical dismantling of the anastomosis and diversion.ConclusionThe CAR™ 27 device shows promise as a safe and effective alternative for the creation of colorectal anastomoses. However, studies in a larger patient population are warranted to demonstrate equivalence of this device

    Utilization of livers donated after circulatory death for transplantation - An international comparison.

    Get PDF
    BACKGROUND AND AIM Liver graft utilization rates are a hot topic due to the worldwide organ shortage and an increasing number of transplant candidates on waiting lists. Liver perfusion techniques have been introduced in several countries, and may help to increase the organ supply, as they potentially allow the assessment of livers before use. METHODS Liver offers were counted from donation after circulatory death (DCD) donors (Maastricht-type-III) arising during the past decade in eight countries, including Belgium, France, Italy, the Netherlands, Spain, Switzerland, UK, and US. Initial DCD-type-III liver offers were correlated with accepted, recovered and implanted livers. RESULTS A total number of 34`269 DCD livers were offered, resulting in 9`780 liver transplants (28.5%). The discard rates were highest in UK and US, ranging between 70 and 80%. In contrast, much lower DCD liver discard rates, e.g., between 30-40%, were found in Belgium, France, Italy, Spain and Switzerland. In addition, large differences were recognized in the use of various machine perfusion techniques, and in terms of risk factors in the cohorts of implanted livers. For example, the median donor age and functional donor warm ischemia were highest in Italy, e.g., >40minutes, followed by Switzerland, France, and the Netherlands. Importantly, such varying risk profiles of accepted DCD livers between countries did not translate into large differences in five-year graft survival rates, which ranged between 60-82% in this analysis. CONCLUSIONS We highlight a significant number of discarded and consequently unused DCD liver offers. Countries with more routine use of in- and ex-situ machine perfusion strategies showed better DCD utilization rates without compromised outcome. IMPACT AND IMPLICATIONS A significant number of Maastricht type III DCD livers are discarded across Europe and North America today. The overall utilization rate among eight Western countries is 28.5%, but varies significantly between 18.9% and 74.2%. For example, the median DCD III liver utilization in five countries, e.g., Belgium, France, Italy, Switzerland, and Spain is 65%, in contrast to 24% in the Netherlands, UK and US. Despite this, and despite different rules and strategies for organ acceptance and preservation, the one and five-year graft survival remains currently relatively comparable among all participating countries. Factors which impact on DCD liver acceptance rates include the national pre-selections of donors, before the offer is made, as well as cutoffs for key risk factors, including donor age and donor warm ischemia time. In addition, a highly varying experience with modern machine perfusion technology is noticed. In situ and ex situ liver perfusion concepts, and assessment tools for type III DCD livers before transplantation may be one key part for the observed differences in better DCD III utilization