345 research outputs found

    Neutron spectral measurements in the upper atmosphere

    Get PDF
    An experiment to measure neutrons in the upper atmosphere was performed on a balloon flight from Palestine, Texas, at an altitude of about 32 km. The experimental arrangement is discussed briefly, and results of a preliminary analysis of the data for neutrons in the energy range 3 to 30 MeV are given

    Wireless, in-vessel neutron monitor for initial core-loading of advanced breeder reactors

    Get PDF
    An experimental wireless, in-vessel neutron monitor was developed to measure the reactivity of an advanced breeder reactor as the core is loaded for the first time to preclude an accidental critically incident. The environment is liquid sodium at a temperature of approx. 220 C, with negligible gamma or neutron radiation. With ultrasonic transmission of neutron data, no fundamental limitation was observed after tests at 230 C for 2000 h. The neutron sensitivity was approx. 1 count/s-nv, and the potential data transmission rate was approx. 10,000 counts/s

    Test–retest reliability of freesurfer measurements within and between sites: Effects of visual approval process

    Full text link
    In the last decade, many studies have used automated processes to analyze magnetic resonance imaging (MRI) data such as cortical thickness, which is one indicator of neuronal health. Due to the convenience of image processing software (e.g., FreeSurfer), standard practice is to rely on automated results without performing visual inspection of intermediate processing. In this work, structural MRIs of 40 healthy controls who were scanned twice were used to determine the test–retest reliability of FreeSurfer‐derived cortical measures in four groups of subjects—those 25 that passed visual inspection (approved), those 15 that failed visual inspection (disapproved), a combined group, and a subset of 10 subjects (Travel) whose test and retest scans occurred at different sites. Test–retest correlation (TRC), intraclass correlation coefficient (ICC), and percent difference (PD) were used to measure the reliability in the Destrieux and Desikan–Killiany (DK) atlases. In the approved subjects, reliability of cortical thickness/surface area/volume (DK atlas only) were: TRC (0.82/0.88/0.88), ICC (0.81/0.87/0.88), PD (0.86/1.19/1.39), which represent a significant improvement over these measures when disapproved subjects are included. Travel subjects’ results show that cortical thickness reliability is more sensitive to site differences than the cortical surface area and volume. To determine the effect of visual inspection on sample size required for studies of MRI‐derived cortical thickness, the number of subjects required to show group differences was calculated. Significant differences observed across imaging sites, between visually approved/disapproved subjects, and across regions with different sizes suggest that these measures should be used with caution. Hum Brain Mapp 36:3472–3485, 2015. © 2015 Wiley Periodicals, Inc.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/113142/1/hbm22856.pd

    What is the easier and more reliable dose calculation for iv Phenytoin in children at risk of developing convulsive status epilepticus, 18 mg/kg or 20 mg/kg?

    Get PDF
    Background: With the Convulsive Status Guidelines due for renewal, we wondered if a phenytoin dose of ‘20 mg/kg’ would be easier to calculate correctly and therefore safer than the current ‘18 mg/kg’. An educational exercise in dose calculation was therefore undertaken to assess ease of calculation. Method: A standard question paper was prepared, comprising five clinical scenarios with children of varying ages and estimated body weights. Medical students, trainee doctors at registrar and senior house officer level, and consultant paediatricians were asked to complete the exercise, in private, by one of two medical students (SD, PS). Calculations were done with and without a calculator, for 18 mg/kg and for 20 mg/kg in randomised order. Speed and errors (greater than 10%) were determined. The data analysis was performed using SPSS version 18. Results: All answered all 20 scenarios, giving a total of 300 answers per doctor/student group, and 300 answers per type of calculation. When comparing the 2 doses, the numbers of errors more than 10% were significantly less in 20 mg/kg dose (0.33%) as compared to the 18 mg/kg dose (9.3%) (p<0.0001). Speed off calculation was significantly decreased in 20 mg/kg dose when compared with 18 mg/kg dose, with (p<0.001) or without (p<0.0001) the calculator. Speed was more than halved and errors were much less frequent by using a calculator, for the 18 mg/kg dose but no difference with or without the calculator for 20 mg/kg dose. Conclusion: We recommend that the future guidelines should suggest iv Phenytoin at 20 mg/kg rather than 18 mg/kg. This will make the calculation easier and reduce the risk of significant errors

    Evaluation of antibiotics as a methodological procedure to inhibit free-living and biofilm bacteria in marine zooplankton culture

    Get PDF
    There is a problem with keeping culture medium completely or partially free from bacteria. The use of prokaryotic metabolic inhibitors, such as antibiotics, is suggested as an alternative solution, although such substances should not harm non-target organisms. Thus, the aim of this study was to assess the effectiveness of antibiotic treatments in inhibiting free-living and biofilm bacteria and their half-life in artificial marine environment using the copepod Acartia tonsa as bioindicador of non-harmful antibiotic combinations. Regarding to results, the application of 0.025 g L-1 penicillin G potassium + 0.08 g L-1 streptomycin sulphate + 0.04 g L-1 neomycin sulphate showed great potential for use in marine cultures and scientific experiments without lethal effects to non-target organisms. The effect of this combination starts within the first six hours of exposure and reduces up to 93 % the bacterial density, but the half-life is short, requiring replacement. No adverse changes in water quality were observed within 168 hours of exposure. As a conclusion, we can infer that this treatment was an effective procedure for zooplankton cultures and scientific experiments with the aim of measuring the role of free-living and biofilm in the marine community

    A Comprehensive Examination Of White Matter Tracts And Connectometry In Major Depressive Disorder

    Get PDF
    Background Major depressive disorder (MDD) is a debilitating disorder characterized by widespread brain abnormalities. The literature is mixed as to whether or not white matter abnormalities are associated with MDD. This study sought to examine fractional anisotropy (FA) in white matter tracts in individuals with MDD using diffusion tensor imaging (DTI). Methods 139 participants with MDD and 39 healthy controls (HC) in a multisite study were included. DTI scans were acquired in 64 directions and FA was determined in the brain using four methods: region of interest (ROI), tract-based spatial statistics (TBSS), and diffusion tractography. Diffusion connectometry was used to identify white matter pathways associated with MDD. Results There were no significant differences when comparing FA in MDD and HC groups using any method. In the MDD group, there was a significant relationship between depression severity and FA in the right medial orbitofrontal cortex, and between age of onset of MDD and FA in the right caudal anterior cingulate cortex using the ROI method. There was a significant relationship between age of onset and connectivity in the thalamocortical radiation, inferior longitudinal fasciculus, and cerebellar tracts using diffusion connectometry. Conclusions The lack of group differences in FA and connectometry analysis may result from the clinically heterogenous nature of MDD. However, the relationship between FA and depression severity may suggest a state biomarker of depression that should be investigated as a potential indicator of response. Age of onset may also be a significant clinical feature to pursue when studying white matter tracts

    Raspodjela lindana u vodi, sedimentu i ribama iz rijeke Warri (Delta Nigera, Nigerija)

    Get PDF
    This paper is the first attempt to quantify the levels and the distribution pattern of lindane in the surface water, sediment and fish (Chrysichthys furcatus and Tilapia zilli). The samples were collected from three stations (Ovwian, Ekakpamre, and Ovu) of the Warri River in the western Niger Delta of Nigeria in 2006: during the dry (January-April) and wet seasons (May-August). The analysis included a total of 96 samples made up of 24 samples each for water, sediment, and fish. The pesticide levels were analysed using high performance liquid chromatography to elucidate its distribution in various environmental compartments. Residue levels in the matrices ranged from below the detection limit (BDL) to 1.37µg L-1 in water, BDL to 12.66 µg g-1 dry weight (dw) in sediment, BDL to 16.67 µg g-1dw in Chrysichthys furcatus, and BDL to 0.15 µg g-1dw in Tilapia zilli .The observed values were above the ecological benchmarks (0.01 µg L-1) recommended by the Nigerian Environmental Protection Agency and European Union. They were also relatively higher than in previous studies on the Nigerian environment, which calls for regular monitoring of the Niger Delta water bodies.Istražene su pojava i raspodjela lindana u površinskoj vodi, sedimentu i dvije vrste riba Chrysichthys furcatus i Tilapia zilli iz rijeke Warri u zapadnom dijelu delte Nigera (Nigerija). Uzorci su skupljeni 2006. godine na tri postaje (Ovwian, Ekakpamre i Ovu) tijekom sušne (siječanj - travanj) i vlažne sezone (svibanj - kolovoz). Analizirano je ukupno 96 uzoraka: po 24 uzorka vode, sedimenta i riba. Razine pesticida odre|ene su primjenom tekućinske kromatografije visoke djelotvornosti (HPLC) te je utvr|ivana njihova raspodjela u različitim dijelovima okoliša. Koncentracije rezidua u uzorcima vode bile su u rasponu: ispod granice detekcije (BDL) do 1,37 µg L-1, u sedimentu: BDL do 12,66 µg g-1 suhe tvari, u ribama Chrysichthys furcatus: BDL do 16,67 µg g-1 suhe tvari te Tilapia zilli: BDL do 0,15 µg g-1 suhe tvari. Određene vrijednosti bile su ispod graničnih vrijednosti (0,01 µg L-1) propisanih od Nigerijske uprave za zaštitu okoliša i Europske unije. Kako su dobivene vrijednosti bile relativno više u odnosu na podatke iz ranijih istraživanja okoliša u Nigeriji, istaknuta je potreba trajnog monitoringa vodotoka u delti Nigera
    corecore