    Modular assembly of a single phase inverter based on integrated functional block

    Get PDF
    This paper presents an original modular plug-in type assembly approach for a single phase-inverter. The main focus here is, indicatively, on the power range 1-20 kW, but the methodology can be transferred to higher power levels, too. At the core of the inverter lies a power-dense double-sided-cooled half-bridge power switch architecture with integrated cooler, which is interconnected to filter elements, gate-driver and control circuitry by means of compact flat connectors. The integration exercise targets, on the one hand, the optimization of the power switch performance and reliability, as well as the reduction of circuit parasitic elements; on the other, the production of a system compatible with maintenance and repairing, featuring minimized impact of single component failure on the system maintenance and repair cost and thus on its availability. Preliminary experimental tests demonstrate the nominal functionality of the inverter

    Introduction (<Special Sessions>International Symposium in Shanghai : Multilateral Comparative Study of the Historical Archives : Historical Documents, and Family, Business and Society in East Asia)

    Get PDF
    This paper presents the work on an alternative integration scheme for a half-bridge switch using 70 μm thin Si IGBTs and diodes addressing higher strength, higher toughness and higher thermal conductivity. The switch is totally bond wireless, since bonded wires increase self-heating and introduce further thermomechanical degradation mechanisms. Moreover, this solution is equipped with double side liquid cooling, and plug-in edge connectors both on the driver and load sides, allowing high power density, good accessibility and modularity. Preliminary experimental results show good switching behavior

    CHARM facility remotely controlled platform at CERN: A new fault-tolerant redundant architecture

    Get PDF
    Many power electronics applications require high tolerance to faults such as short circuit or open circuit of the control signals. One such application is the CERN High energy AcceleRator Mixed-field (CHARM) facility, where maintenance may be precluded for long periods of time due to radiation and, therefore, high reliability is necessary. A redundant interconnection architecture for the control signals is proposed, where each signal is individually processed by different CPUs and transmitted through separate interconnection lines. During normal operation, the CPUs are synchronized and produce the same signals. The purpose of the proposed hardware and firmware strategy is to allow the actuator to continue operating even in case of fault; regardless of the fault type (open circuit, short circuit to ground or to positive supply), a fault on one of the parallel lines would not inhibit the correct operation of the remaining line. This solution can be used to control the movements of a target system using a remote joystick in a safe environment. The architecture features reliable transmission of PWM signals driving a half-bridge power converter. Moreover, it is possible to extend it to any type of converter such as three-phase bridges, three-level NPC, or buck-boost converters. Simulations and experimental results show a good agreement, proving the effectiveness of the proposed fault tolerant circuitry

    Abstractive Summarization of Voice Communications

    Get PDF
    Abstract summarization of conversations is a very challenging task that requires full understanding of the dialog turns, their roles and relationships in the conversations. We present an efficient system, derived from a fully-fledged text analysis system that performs the necessary linguistic analysis of turns in conversations and provides useful argumentative labels to build synthetic abstractive summaries of conversations

    Effect of Sugars on Gelation Kinetics of Gelatin Gels

    Get PDF
    We investigate the rheological behavior of aqueous solutions containing animal gelatin, sugars and polyols. The aim is to study how the gelation kinetics, transition temperatures and gel strengths of an aqueous gelatin solution can be affected by the progressive addition of co-solutes. Aqueous solutions with a fixed mass percentage of gelatin of 6.8 wt% were prepared at various concentrations of sugars and polyols. Through Dynamic Temperature Ramp tests, performed at various ramp rates, and Dynamic Time Sweep and Dynamic Frequency Sweep tests, carried out at different temperatures, it was possible both to evaluate the transition temperatures and to monitor the gelation kinetics of the samples. It was found that the contribution of co-solutes positively affects both the gelation process and the thermal stability of the aqueous gelatin solution by reducing the gelation time and improving the mechanical properties of the gel in terms of network elasticity

    Robust snubberless soft-switching power converter using SiC power MOSFETs and bespoke thermal design

    Get PDF
    A number of harsh-environment high-reliability applications are undergoing substantial electrification. The converters operating in such systems need to be designed to meet both stringent performance and reliability requirements. Semiconductor devices are central elements of power converters and key enablers of performance and reliability. This paper focuses on a DC–DC converter for novel avionic applications and considers both new semiconductor technologies and the application of design techniques to ensure, at the same time, that robustness is maximized and stress levels minimized. In this respect close attention is paid to the thermal management and an approach for the heatsink design aided by finite element modelling is shown

    New generation anaplastic lymphoma kinase inhibitors

    Get PDF
    Anaplastic lymphoma kinase (ALK) gene translocations are pro-tumoral driver alterations that encompass 3*7% of non-squamous non-small cell lung cancer (NSCLC) with specific, clinic and histologic features. The therapeutic strategy depends on anti-ALK tyrosine kinase inhibitors (TKIs) of which crizotinib was the first approved for clinical use. Despite its use improved significantly progression-free survival, overall response rate and duration of response of this illness, after a median period of 10.9 months all patients progress due to the development of acquired resistance mutations in the ALK tyrosine kinase domain in approximately one third of patients. Moreover, 60-90% of patients treated with crizotinib has a progression in the central nervous system (CNS) in absence of extracranial worsening of the disease. This is primarily attributed to poor CNS penetration by crizotinib as many pre-clinical and clinical models suggest. For instance, in order to overtake acquired resistance to crizotinib, prolong the control of the disease and manage CNS localizations, several II and III generation TKIs have been developed. Some of them were approved after the failure of crizotinib (ceritinib, alectinib, brigatinib and lorlatinib) and in first line setting (ceritinib, alectinib and brigatinib) while others are still under evaluation for TKI-naive patients such as lorlatinib, ensartinib and entrectinib. In this review we will discuss the most recent results of new TKIs in order to describe a fast growing therapeutic landscape in this setting

    Correlation between OCVD carrier lifetime vs temperature measurements and reverse recovery behavior of the body diode of SiC power MOSFETs

    Get PDF
    The reverse recovery (RR) behavior of SiC MOSFET body diode is of great importance in power application, where these devices are used in a wide range of operating temperatures. The carrier lifetime in the drift region varies with temperature, and it heavily affects the tailoring of the RR current, opening reliability issues related to the RR voltage amplitude and to possible anomalous voltage oscillations during the recovery. From the users' point of view, it would be useful to have a simple technique able to give predictive information about the body diode RR behavior of commercial devices over the whole range of working temperatures. An experimental-simulation approach is presented in this paper to correlate the carrier lifetime measured by simple OCVD measurements versus temperature with the RR behavior of the body diode, that can be useful at the design stage of power converters. Simulations of the body diode reverse-recovery are performed for a wide range of carrier lifetimes. This allows to estimate the effect of changes of carrier lifetime with temperature on the body diode switching transients. Preliminary results obtained with a 1700 V/5A commercial MOSFET are shown

    Two-dimensional impurity imaging in deep Antarctic ice cores: snapshots of three climatic periods and implications for high-resolution signal interpretation

    Get PDF
    Due to its micrometer-scale resolution and inherently micro-destructive nature, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is particularly suited to exploring the thin and closely spaced layers in the oldest sections of polar ice cores. Recent adaptions to the LA-ICP-MS instrumentation mean we have faster washout times allowing state-of-the-art 2-D imaging of an ice core. This new method has great potential especially when applied to the localization of impurities on the ice sample, something that is crucial, to avoiding misinterpretation of the ultra-fine-resolution signals. Here we present the first results of the application of LA-ICP-MS elemental imaging to the analysis of selected glacial and interglacial samples from the Talos Dome and EPICA Dome C ice cores from central Antarctica. The localization of impurities from both marine and terrestrial sources is discussed, with special emphasis on observing a connection with the network of grain boundaries and differences between different climatic periods. Scale-dependent i mage analysis shows that the spatial significance of a single line profile along the main core axis increases systematically as the imprint of the grain boundaries weakens. It is demon-strated how instrumental settings can be adapted to suit the purpose of the analysis, i.e., by either employing LA-ICP-MS to study the interplay between impurities and the ice microstructure or to investigate the extremely thin climate proxy signals in deep polar ice

    Impact of phonons on dephasing of individual excitons in deterministic quantum dot microlenses

    Get PDF
    Optimized light-matter coupling in semiconductor nanostructures is a key to understand their optical properties and can be enabled by advanced fabrication techniques. Using in-situ electron beam lithography combined with a low-temperature cathodoluminescence imaging, we deterministically fabricate microlenses above selected InAs quantum dots (QDs) achieving their efficient coupling to the external light field. This enables to perform four-wave mixing micro-spectroscopy of single QD excitons, revealing the exciton population and coherence dynamics. We infer the temperature dependence of the dephasing in order to address the impact of phonons on the decoherence of confined excitons. The loss of the coherence over the first picoseconds is associated with the emission of a phonon wave packet, also governing the phonon background in photoluminescence (PL) spectra. Using theory based on the independent boson model, we consistently explain the initial coherence decay, the zero-phonon line fraction, and the lineshape of the phonon-assisted PL using realistic quantum dot geometries